background image

5

HUMIDIFIER CORD
PLUGGED INTO 120 VAC 
POWER SOURCE

SEE WIRI NG

INSTRUCTIONS

INCLUDED WITH

5387 RELAY

HUMIDIFIER

24 VAC  LEADS

#5387 BLOWER

ACTIVATION RELAY

MANUAL
HUMIDIFIER
CONTROL

CONSTANT 24 VAC
MIN 10 VA

A13316

Fig. 12 -- Typical Wiring to Standard Fan Coil

INDOOR

UNIT

EQUIPMENT

CONTROLLER

C

HUM

24 VAC
LEADS

HUMIDIFIER

HUMIDIFIER CORD
PLUGGED INTO
120 VAC POWER SOURCE

A13317

Fig. 13 -- Typical Wiring for Zoning Hook--Up

HUMIDIFIER

24 VAC
LEADS

HUM

C

D

C

B

A

INDOOR

UNIT

HUMIDIFIER CORD
PLUGGED INTO
120 VAC POWER SOURCE

A13318

Fig. 14 -- Wiring for New Communicating Control Hook--Up

Summary of Contents for HUMXXSFP1012

Page 1: ...ry or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or d...

Page 2: ...evaporator pad removal NOTE The humidifier is not suitable for installation on ducts with horizontal airflow Performance will be reduced VERTICAL EVAP COIL A13330 Fig 3 Installation Location of Fan type Humidifier Step 3 Prepare Plenum Opening 1 In the selected location on the supply plenum carefully mark the maximum dimensions of the opening 11 3 8 in 29 2 cm wide by 11 1 4 in 28 6 cm high NOTE T...

Page 3: ...t tached to that end Distribution Tray Note Black Marking indicates top of pad A13327 Fig 6 Water Distribution Tray Placement 8 Place the water panel with attached distribution tray inside the base frame making sure the tray ends slide over the guide flanges and that the tray top flange seats flush The black marking indicates the top of pad 9 Attach the front panel assembly to the frame ensuring t...

Page 4: ...r line with the saddle valve The saddle valve should completely penetrate the supply line and be fully open Refer to instructions on packaging of saddle valve A13326 Fig 10 Pierce Water Line with Saddle Valve 5 Open the water supply line 6 Check for leaks at saddle valve and at solenoid valve con nections Step 7 Install the Humidistat The humidistat included with this unit can be either wall mount...

Page 5: ... 24VAC MIN 10 VA A13316 Fig 12 Typical Wiring to Standard Fan Coil INDOOR UNIT EQUIPMENT CONTROLLER C HUM 24 VAC LEADS HUMIDIFIER HUMIDIFIER CORD PLUGGED INTO 120 VAC POWER SOURCE A13317 Fig 13 Typical Wiring for Zoning Hook Up HUMIDIFIER 24 VAC LEADS HUM C D C B A INDOOR UNIT HUMIDIFIER CORD PLUGGED INTO 120 VAC POWER SOURCE A13318 Fig 14 Wiring for New Communicating Control Hook Up ...

Page 6: ...ult Lower humidistat setting in small steps until condensation disappears However if air is too dry raise the setting The table below should be used as a guideline for recommended humidistat settings RECOMMENDED HUMIDISTAT SETTING OUTSIDE TEMPERATURES RECOMMENDED HUMIDISTAT SETTING 20 F 29 C 15 10 F 23 C 20 LO 0 F 18 C 25 10 F 12 C 30 20 F 7 C 35 30 F 1 C 40 MED Step 10 Final Steps 1 Inform homeow...