GB - 6

Dehumidification

3

4

5

6

7

8

9

10

11

1

2

TURBO

SILENT

TURBO

SILENT

5 MIN.

The dehumidification only function should be used if you want
to remove moisture from the room air without lowering the
temperature.
Place the unit in the space to be dehumidified (room, garage,
cellar or storeroom).

Plug the unit in.
Open the air flow direction guide vane.
Turn the mode selector to the dehumidification symbol.

The dehumidification indicator light
on the control panel is illuminated.
The air conditioner removes moisture from
the air without lowering the temperature.

If the two red indicator lights
on the control panel light up,
this shows that the condensate water
collection tank is full.
If this is the case the unit automatically
switches off.

To empty the tank, switch the unit off by
turning the mode selector to the   symbol.

Remove the plug from the power
supply socket.

Remove the outdoor unit if it is attached to
the indoor unit.

Take out the full water tank on the rear
side of the air conditioner and empty it.
Then replace it correctly in its position.

If the dehumidification mode
is again required, plug in the unit
and wait 5 minutes before
again turning the mode selector
to the dehumidification symbol.

In certain applications a floor drain may
be provided and it may be easier to use
the drain tube to remove the condensate
water directly. Proceed as follows:
• pull out the 60 mm long condensate

drain tube and remove the plug.

• Connect the drain tube to the floor drain

using a rubber tube.

After use remember to put the plug into
the drain tube and to replace
the tube in its position.

Summary of Contents for Holiday 51AKB

Page 1: ...51AKB 51AKC OWNER S MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 ...

Page 2: ...de selector 4 SILENT cooling 5 Dehumidification 6 Thermostat 7 Low fan speed 8 High fan speed 9 Alarm indicator light 10 Fan speed indicator lights 11 Cooling indicator light 12 Dehumidification indicator light 1 Mounting brackets for the outdoor unit 2 Screws nuts and washers for fixing the mounting brackets 3 Fastening strap with suction cup 4 Strap with spring clips GB 1 ENGLISH This manual app...

Page 3: ... on your own To avoid electric shock or fire make sure these operations are carried out by qualified personnel only Contact the qualified service if one of the following events takes place hot or damaged power supply cable unusual noise during operation frequent operation of the protection devices unusual smell such as smell of burning Choosing the installation site Choose an area free from obstru...

Page 4: ...ure and counterclockwise to raise it Adjusting the air flow direction The air conditioner has a guide vane at the top that can be adjusted to any angle between 10 partially closed and 60 fully open Depending on the angle the air flow direction changes as shown Never use the air conditioner with the guide vane closed Never let the outdoor unit hang on the flexible tube Never move either unit by pul...

Page 5: ...ate water The flexible tube can be trapped between two shutters set ajar For this solution use the window suction cup supplied as shown Making a cut out of 35 x18 mm in the lower window or door frame to accomodate the flexible tube allows the unit to be used with the window or door closed For window sill installation use the supplied bracket and screws Fix the bracket to the waindow sill as shown ...

Page 6: ...the control knob clockwise The cooling mode indicator light on the control panel is illuminated When the desired room temperature is reached turn the thermostat control knob counterclockwise until the cooling indicator light switches off In this way the desired room temperature is automatically maintained To switch the unit off turn the mode selector counterclockwise to the symbol Place the flexib...

Page 7: ...s the case the unit automatically switches off To empty the tank switch the unit off by turning the mode selector to the symbol Remove the plug from the power supply socket Remove the outdoor unit if it is attached to the indoor unit Take out the full water tank on the rear side of the air conditioner and empty it Then replace it correctly in its position If the dehumidification mode is again requ...

Page 8: ...grilles of the air conditioner filtered and cleaned and then returned to the room through the front and rear air supply grilles To clean the appliance use only a damp cloth and soap Never use spray or flammable liquids Periodically clean the air filters in the sides of the unit To pull out the filters from their position use the tab on the outside edge First clean the filters with a vacuum cleaner...

Page 9: ...the unit off turning the mode selector counterclockwise to symbol and remove the plug from the power supply socket Using the special tool unscrew the fixing screw and remove the closing cover Disconnect the electrical connector Disconnect the ground wire of the outdoor section using a Philips screwdriver Loosen the fixing clamp of the small tube that takes condensing water to the outdoor unit taki...

Page 10: ...26H61 0405 Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice April 2005 Supersedes January 2005 Printed in Italy ...

Reviews: