Correct use

Unit installation

Read this instruction manual thoroughly
before installing the unit and keep it for
further consultation even after installation.
• This unit complies with the following

directives:

- low-voltage 73/23/CEE;
- electromagnetic compatibility 89/336/CEE;
- PED Pressure Equipment 97/23/CE;
- energy labelling 2002/31/CE.
• For safety reasons, installers are required to

read the general information carefully.

• Follow all the instructions below to ensure

safety.

• Inspect the unit for damage due to improper

transport. In case of damage, file an
immediate claim with the shipping company.

• Do not install or use damaged equipment.
• To prevent fire, explosion or injury, do not

operate the unit near dangerous substances
or close to naked light equipment.

• Ensure that national safety code

requirements have been followed for the
main supply circuit. Follow all current
national safety code requirements for the
installation.

• Make sure a connected ground wire is in

place.

• Check that voltage and frequency of the

mains power supply are those required for
the unit to be installed; the available power
must be adequate to operate any other
appliances connected to the same line.

• The manufacturer declines any liability from

damage resulting from modifications in the
unit or errors in the electrical or hydraulic
connections.
Failure to observe the installation
instructions, or use of the unit under
conditions other than those indicated in the

table “Operating limits” of the unit owner’s
manual, will immediately invalidate the unit
warranty.

• It is recommended to install a circuit breaker

or a 16 A safety fuse upstream of the supply
outlet.

Unit operation

• In order to avoid electric shock, fire or injury,

stop the unit in case of abnormal events
(such as smell of burning) and call Carrier
Service for further instructions.

• Do not place containers filled with liquids or

other objects onto the unit.

Maintenance

WARNING:
disconnect the mains power supply prior
to any maintenance operations or prior to
handling any internal parts of the unit.

• A routine maintenance should be carried out

on the unit to check the correct operation of
the electric connections and protection
devices.

• A damaged power cord of units equipped

with quick-connection couplings of the Y-type
must be replaced by the manufacturer or its
after-sales service.

• Maintenance operations must be carried out

by specially trained personnel.

• Do not attempt to repair, move, modify the

unit on your own. To avoid electric shock or
fire make sure these operations are carried
out by qualified personnel only.

• Contact the qualified service if one of the

following events takes place:
- hot or damaged power supply cable;
- unusual noise during operation;
- frequent operation of the protection  devices;
- unusual smell (such as smell of burning).

Choosing the installation site

• Choose an area free from obstructions which

may cause irregular air distribution and/or return.

• Choose a position that allows for the clearances

required (see “Correct use” section).

• Look for a position in the room which

assures the best possible air distribution.

Positions to avoid:
• Exposed to direct sun.
• Too close to heat sources.
• On humid walls or positions with water

hazard, e.g. laundry premises.

• Exposure to oil vapours (e.g. kitchens,

workshops).

• Where curtains or furniture may obstruct free

air circulation.

Unit disposal:

• At the end of its life, the air conditioner must

be delivered to a special collection centre or
to the dealer for the refrigerant disposal.

• All of the manufacturing and packaging

materials used for this unit  are compatible
with the environment and can be recycled.

• Dispose of the packaging material in

accordance with local requirements.

SPLIT unit performance:

The unit is designed to operate within the following
temperature limits according to the standards:
Cooling: (EN14511:2004)
Indoor temperature
Max. 32

°

C d.b.* / 23

°

C w.b.*

Min. 21

°

C d.b.* / 15

°

C w.b.*

Outdoor temperature:
Max. 46

°

C - Min. 21

°

C

Dehumidification:
Max 32

°

C d.b.* / 24

°

C w.b.*

Min. 18

°

C d.b.* / 14

°

C w.b.*

* d.b. - dry bulb temperature -
* w.b. - wet bulb temperature

The air conditioner models
51AKB010  consist of two
units connected by a flexible
tube of 1.8 metre length.
Models 51AKC013 sare
provided with a flexible tube
of 3.6 metre length and
quick coupling connections
that allow the units to be
disconnected up to a
maximum of six times
without impairing air
conditioning performance.
This operation must
always be carried out by
qualified and authorized
personnel.

The elegant portable indoor unit may be
positioned conveniently in the room to be air conditioned.

The compact, light weight
outdoor unit is placed
outdoors.

The outdoor unit
may be hung on
the back of the
indoor unit with the
flexible tube neatly
coiled, but never
kinked, to allow air
conditioner to be
moved from room
to room. It is
recommended to
move the unit
holding the front
panel as illustrated.

IMPORTANT
At first start-up of the unit proceed
as follows:

• take out the water tank at the rear

of the air conditioner

• remove the adhesive tape strip
• replace the tank correctly in its

position

If the above procedure is not followed,
the unit will not operate and indicate a
fault.

Summary of Contents for Holiday 51AKB

Page 1: ...51AKB 51AKC OWNER S MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 ...

Page 2: ...de selector 4 SILENT cooling 5 Dehumidification 6 Thermostat 7 Low fan speed 8 High fan speed 9 Alarm indicator light 10 Fan speed indicator lights 11 Cooling indicator light 12 Dehumidification indicator light 1 Mounting brackets for the outdoor unit 2 Screws nuts and washers for fixing the mounting brackets 3 Fastening strap with suction cup 4 Strap with spring clips GB 1 ENGLISH This manual app...

Page 3: ... on your own To avoid electric shock or fire make sure these operations are carried out by qualified personnel only Contact the qualified service if one of the following events takes place hot or damaged power supply cable unusual noise during operation frequent operation of the protection devices unusual smell such as smell of burning Choosing the installation site Choose an area free from obstru...

Page 4: ...ure and counterclockwise to raise it Adjusting the air flow direction The air conditioner has a guide vane at the top that can be adjusted to any angle between 10 partially closed and 60 fully open Depending on the angle the air flow direction changes as shown Never use the air conditioner with the guide vane closed Never let the outdoor unit hang on the flexible tube Never move either unit by pul...

Page 5: ...ate water The flexible tube can be trapped between two shutters set ajar For this solution use the window suction cup supplied as shown Making a cut out of 35 x18 mm in the lower window or door frame to accomodate the flexible tube allows the unit to be used with the window or door closed For window sill installation use the supplied bracket and screws Fix the bracket to the waindow sill as shown ...

Page 6: ...the control knob clockwise The cooling mode indicator light on the control panel is illuminated When the desired room temperature is reached turn the thermostat control knob counterclockwise until the cooling indicator light switches off In this way the desired room temperature is automatically maintained To switch the unit off turn the mode selector counterclockwise to the symbol Place the flexib...

Page 7: ...s the case the unit automatically switches off To empty the tank switch the unit off by turning the mode selector to the symbol Remove the plug from the power supply socket Remove the outdoor unit if it is attached to the indoor unit Take out the full water tank on the rear side of the air conditioner and empty it Then replace it correctly in its position If the dehumidification mode is again requ...

Page 8: ...grilles of the air conditioner filtered and cleaned and then returned to the room through the front and rear air supply grilles To clean the appliance use only a damp cloth and soap Never use spray or flammable liquids Periodically clean the air filters in the sides of the unit To pull out the filters from their position use the tab on the outside edge First clean the filters with a vacuum cleaner...

Page 9: ...the unit off turning the mode selector counterclockwise to symbol and remove the plug from the power supply socket Using the special tool unscrew the fixing screw and remove the closing cover Disconnect the electrical connector Disconnect the ground wire of the outdoor section using a Philips screwdriver Loosen the fixing clamp of the small tube that takes condensing water to the outdoor unit taki...

Page 10: ...26H61 0405 Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice April 2005 Supersedes January 2005 Printed in Italy ...

Reviews: