background image

                                                                 (    ) 

30

 

13. TROUBLE

 

SHOOTING 

 

If you have problems with your room air conditioner, check this trouble-shooting guide before contacting 

Carrier or Carrier certified dealer. 
If the abnormality persists and cannot be solved with the given instructions, turn off the air conditioner 

and does not try to turn it on again, call Carrier or Carrier certified dealer. 

 

TROUBLE 

POSSIBLE CAUSES 

SOLUTIONS 

After batteries have 
been placed into the 

remote control, the 
remote control can 

not operate the air 
conditioner. 

Batteries are exhausted or have the 
wrong polarity. 

Replace batteries or check 
polarity. 

When pressing start 

button, unit does not 
acknowledge signal 

with a beep. 
 

OR 
 

When pressing stop 
button, unit does not 

acknowledge signal 
with a beep. 

 
 

Main switch is OFF. 

Switch it to ON position. 

Remote control batteries are exhausted. Replace 

batteries. 

Remote control has not been pointed 

correctly to the receiver of unit. 

Turn remote control OFF and 

repeat the operation in the 
correct direction. 

There are obstacles (curtains, walls, etc.) 

between the remote control and the unit  

Repeat the operation after having 

removed the obstacles. 

Receiver on the unit or the remote 
control is under intense sun radiation. 

Avoid direct sun on the unit, shut 
curtains or shades. 

Signal transmission is obstructed by 

severe interference from an 
electromagnetic field. 

Avoid sending signals when 

computers or household 
appliances (Food processors, 

coffee makers, etc.) are operating 
close by cellular or cordless 

telephones may also interfere 
with the control. 

Air conditioner will 

not start. 

Main supply switch is OFF 

Switch to ON 

Fuses or main switch are blown 

Replace fuses 

Protection against frequent compressor 

cycling is ON 

Wait for 3 minutes. 

Set temperature is higher than the room 

temperature in the cool mode or lower 
than the room temperature in heat mode. 

Correct set temperature. 

Air conditioner does 

not cool the room 
adequately. 

Air flow cannot circulate freely Remove 

obstructions. 

Dirty filters reduce air quantity 

circulating. 

Clean air filters 

Doors and/or windows are open. 

Close doors and windows 

Fan speed has been set to “Low” 

Set fan speed at high speed. 

Set temperature is high in the cool mode.   Correct selected temperature. 
Incidence of strong sun rays in the room  Use shut curtains or shades 
Unit wrongly selected for the room 

Redefines adequate unit for the 
room. 

Air conditioner stops 

during cooling 

TIMER OFF function is working 

Cancel TIMER OFF function 

Room temperature is lower than set 

temperature 

Normal operation 

Ice or frost forms on 
the indoor coil during 

cooling 

Insufficient air circulation 

Remove obstructions in front of 
the unit  

Dirty air filters 

Clean air filters 

 

Summary of Contents for Great-ion 53KHET36

Page 1: ...requirements All specifications subject to change without prior notice according to Carrier policy of continuous development Hi Wall Split Air Conditioners 53KHET36 Cool Only 53QHET36 Heat Pump R22 Qu...

Page 2: ...u midification Horizontal Air flow Auto Swing 36K Auto Fan Speed Vertical Air flow Auto Swing Auto Mode Efficient AMS Efficient Fans Efficient Coils Inner Groove Copper Tubing Hydrophilic Aluminum Fin...

Page 3: ...fficient Indoor Air Quality IAQ CONTENTS PAGE NO 1 GENERAL INFORMATION 1 2 SYSTEM SAFETY PROTECTIONS 2 3 TIPS OF ENERGY SAVING AND OPTIMUM COMFORT 3 4 SPLIT SYSTEM DESCRIPTION 5 5 CONSIDERATIONS FOR R...

Page 4: ...installed to be far away from any flammable materials curtains etc The circuit breaker size must be suitable for air conditioner Disconnect the electrical mains supply prior to any maintenance operat...

Page 5: ...onditioner operation the microprocessor of printed circuit board will memorize the operation setting After the power is recovered the air conditioner operates automatically without remote control afte...

Page 6: ...long period This is harmful to health Don t wait until it is too cold Turn the air conditioner for heating before that Don t exaggerate on the temperature intensity too hot Extreme temperatures are ha...

Page 7: ...to be air conditioned 1 by using SWING function on the remote control 2 by using SWING function vertical supply air louvers to right or left Clean periodically air filters of indoor unit every month...

Page 8: ...Horizontal supply air louver 7 Vertical supply air louvers 8 Air filters 9 Manual control button 10 Power cord 11 Inter connecting refrigerant piping and electrical cables between indoor and outdoor...

Page 9: ...it or transmission indicator on the remote control fails to light 6 Batteries should only be replaced after turning OFF the air conditioner 5 2 INSTRUCTIONS OF USING WIRELESS REMOTE CONTROL 1 The remo...

Page 10: ...nel of the indoor unit then the unit will work in forced AUTO mode the default setting temperature is 24 C 3 Close the panel firmly to its original position CAUTION Once you press the manual control b...

Page 11: ...you press The time alters as quickly as you press the button Keep pressing the button without releasing the time moves forward or backward by 10 minutes depending on which side you press 2 CLOCK butt...

Page 12: ...control display OPERATION led will illuminate on the display panel of indoor unit COOL mode starts after approximately 3 minutes STOP If you want to stop the air conditioner Press ON OFF button again...

Page 13: ...ote control display OPERATION led will illuminate on the display panel of indoor unit HEAT mode starts after approximately 3 minutes STOP If you want to stop the air conditioner Press ON OFF button ag...

Page 14: ...utton again NOTES 1 For Heat Pump System When Auto mode is activated the air conditioner changes the operation mode automatically to cool or heat or fan only mode and also changes fan speed to auto sp...

Page 15: ...pproximately 3 minutes and ionizer operates for refreshing air removing smoke and dust particles Ionizer gives an immediate sensation of energy and well being STOP If you want to stop the air conditio...

Page 16: ...e control display OPERATION led will illuminate on the display panel of indoor unit FAN ONLY mode starts immediately and ionizer operates for refreshing air removing smoke and dust particles Ionizer g...

Page 17: ...structed even partially Adjust supply air direction properly otherwise it might cause discomfort or cause uneven room temperatures Adjust the horizontal louver using the remote control Adjust the vert...

Page 18: ...lfunctions stop the air conditioner once and restart it When the air conditioner is started immediately after it was stopped the horizontal louver might not move for approximately 10 seconds Open angl...

Page 19: ...set fan speed NOTES To cancel TURBO function Press again TURBO button In TURBO function the fan speed can be adjusted TURBO Function is not available with SLEEP function Under cooling mode except For...

Page 20: ...to cancel SLEEP function press any other button SLEEP function with HEAT Mode If you want to operate SLEEP function with Heat mode to save energy and maintain the most comfortable temperature during...

Page 21: ...displayed Each time you press there the button the time moves forward or backward by 10 minutes depending on which one you press The time alters as quickly as you press the button 3 After setting the...

Page 22: ...you press the button the time moves forward or backward by 10 minutes depending on which one you push The time alters as quickly as you press the button 3 After setting the time for TIMER ON function...

Page 23: ...TEMP TIME button to display 6 00 beside the TIMER ON led Wait 3 seconds the TIMER ON time will be registered 3 Press TIMER button again until TIMER OFF led is displayed and setting time is flashing 4...

Page 24: ...ton until TIMER OFF led is displayed and the setting time is flashing 2 Use the TEMP TIME button to display 23 00 beside the TIMER OFF led of the remote control Wait 3 seconds the TIMER OFF time will...

Page 25: ...removing dust The Ionizer gives an immediate sensation of energy and well being START If you want to activate Ionizer function Press Ionizer button FRESH during unit ON then the ionizer led on the led...

Page 26: ...o detect the actual temperature as its location FOLLOW ME function starts when the indoor unit receives the signal from the remote control and the air conditioner is operated by the temperature inform...

Page 27: ...OCK function when you want to prevent settings from being changed accidentally 2 When you press TEMP and buttons as the same time all current settings are locked in and the remote control does not acc...

Page 28: ...ft it up slightly to take ot out from the filter holder then pull it downwards 3 Remove Active Carbon Electrostatic air filter from its support frame as shown in the figure 4 Clean the main filters wi...

Page 29: ...aned with water Then wipe it with a dry cloth Do not use water to clean inside the air conditioner exposure to water can destroy the electrical insulation leading to possible electric shock Do not use...

Page 30: ...epending on the installation environment e g dusty zones etc see below table Indoor Unit Every Month Every Year Clean air filters 3 1 Clean drain pipe 2 Change remote control batteries 4 Outdoor Unit...

Page 31: ...ndoor unit in operation for half a day in the ventilation fan only mode in order to dry all internal parts Switch electric mains supply off Take batteries out of the remote control Clean indoor and ou...

Page 32: ...he air conditioner has not been used for a long time or during first use of the unit 4 Unpleasant smells coming out from the indoor unit Unpleasant smells can be caused by substances accumulated in th...

Page 33: ...ins or shades Signal transmission is obstructed by severe interference from an electromagnetic field Avoid sending signals when computers or household appliances Food processors coffee makers etc are...

Page 34: ...IMER 7 FAN SPEED indicator 8 AUTO FAN SPEED indicator AUTO LOW FAN SPEED indicator LOW MED FAN SPEED indicator MED HIGH FAN SPEED indicator HIGH SLEEP function indicator 9 FOLLOW ME function indicator...

Page 35: ...Down 6 SWING function button Right Left 7 SLEEP function button 8 TURBO function button 9 FRESH Ionizer function button 10 FOLLOW ME function button 11 CLOCK adjusting button 12 TIMER ON or TIMER OFF...

Page 36: ...unit Unpleasant smells can be caused by substances accumulated in the air filter Switch the system OFF and contact an authorized service center to have the filters cleaned Restart unit in the ventila...

Reviews: