440 01 4801 00
33
Specifications subject to change without notice.
Accessories
(See Fig. 37 and 38.)
1. Electronic Air Cleaner (EAC)
Connect an accessory Electronic Air Cleaner (if used) using
1/4--in. female quick connect terminals to the two male
1/4--in. quick--connect terminals on the control board
marked EAC--1 and EAC--2. The terminals are rated for
115VAC, 1.0 amps maximum and are energized during
blower motor operation.
Connect an accessory 24 VAC, 0.5 amp. maximum humidifier (if
used) to the
¼
--in. male quick--connect HUM terminal and
COM--24V screw terminal on the control board thermostat strip.
NOTE
: If the humidifier has its own 24 VAC power supply, an
isolation relay may be required. Connect the 24 VAC coil of the
isolation relay to the HUM and COM/24V screw terminal on the
control board thermostat strip. See Fig. 37.
2. Humidifier (HUM)
The HUM terminal is a 24 VAC output, energized when the blower
is operating during a call for heat.
3. Twinning Connector
The furnace can only be controlled by a single or two--stage
thermostat. A Communicating User Interface will not oper-
ate this furnace when connected to the Communication
Connector. The Communication Connector on the furnace
control board is only for communication between furnaces
twinned together using a factory accessory twinning kit.
Only select sizes can be twinned, refer to Twinning Kit in-
structions for list of approved furnaces. See Fig. 38.
Alternate Power Supplies
This furnace is designed to operate on utility generated power
which has a smooth sinusoidal waveform. If the furnace is to be
operated on a generator or other alternate power supply, the
alternate power supply must produce a smooth sinusoidal
waveform for compatibility with the furnace electronics. The
alternate power supply must generate the same voltage, phase, and
frequency (Hz) as shown in Table 11 or the furnace rating plate.
Power from an alternate power supply that is non-sinusoidal may
damage the furnace electronics or cause erratic operation.
Contact the alternate power supply manufacturer for specifications
and details.
Variable Speed Furnace with Single Stage Air
Conditioner
NOTE 9
Variable Speed Furnace with Two--Stage Air
Conditioner
L09F027
NOTE 9
Variable Speed Furnace with Single Stage Heat
Pump (Dual Fuel)
L09F026
NOTE 9