Table 2: Start-Up Error Codes

Table 3: Operating Error Codes

Edition Date: 7/2020

Catalog No.: QSG-DGAPA-01

 

Replaces:  New

© 2020 Carrier. All rights reserved.

Manufacturer reserves the right to change, at any time, specifications and designs without obligations.

Third-party trademarks are the property of their respective owners.

ERROR AND STATUS CODES

6

Indicator Light 

Code

Explanation

Possible Cause

Recommended Action

Two flashes

Filter ground circuit fault

No filter installed

Place filter in air purifier

Filter installed 

incorrectly

Install filter in correct orientation as 

indicated by airflow direction arrows on 

cabinet and filter

Wrong type of 

filter installed

Install a genuine air purifier 

replacement filter

Wet filter

Call service to locate and eliminate the 

source of water on the filter and replace 

the filter with a new filter

Damaged filter 

contact spring on 

door assembly

Verify that filter contact springs mounted on 

door are properly contacting the aluminum 

contact pads on the filter and not contacting 

the cabinet or door back; if springs are 

broken or damaged replace the  

door assembly

Rapid flashing  

(five flashes per 

second)

LED flashes for 10 seconds 

when AC power is turned on 

indicating a previously stored 

error code; code will be 

displayed after 10 seconds; 

purifier will not operate until 

cause of error condition is 

rectified and purifier is reset

An error code was 

registered in the 

purifier controls prior 

to the purifier being 

turned off

The purifier controls may be reset during 

the 10 seconds in which the LED is 

flashing rapidly; see the Reset Procedure 

on previous page; if the problem persists, 

follow the actions recommended in Table 3 

for the stored error code or call service

Indicator Light 

Code

Explanation

Possible Cause

Recommended Action

Four flashes

Ionizer/filter 

current imbalance

Dirty Filter Enhancement Module 

(FEM)

Clean/service air purifier unit

Damaged FEM

Replace the filter enhancement modules

Five flashes

Over-current fault

Excessively dirty damaged FEM 

and/or filter

Clean/service air purifier unit

Wet damaged FEM and/or filter

Call service to locate and eliminate the 

source of water in the air purifier, Verify 

that the purifier FEM and cabinet are clean 

and replace filter with a new filter

Damaged filter

Replace the filter element

Damaged FEM

Replace the filter enhancement module

Foreign object inside air purifier Remove foreign object from air purifier and 

ensure purifier is clean and undamaged

Six flashes

Arc detected

Damaged filter

Replace the filter element

Damaged FEM

Replace the filter enhancement module

Foreign object inside air purifier Remove foreign object from air purifier and 

ensure purifier is clean and undamaged

Summary of Contents for DGAPA 1625 Series

Page 1: ...sory Kits are available if your installation does not match these recommendations see KIT160000 or KIT161000 Models DGAPAXX1625 DGAPAXX2025 DGAPAXX1620 DGAPAXX2020 DGAPAXX2420 There are three main mounting options for the air purifier product top mount bottom mount or side mount The location of the Air Purifier should be readily accessible Enough room should be provided for periodic replacement of...

Page 2: ...ound Chassis A Route the power conduit from the purifier to a knockout on the furnace that provides access to the EAC terminals on the furnace control board Affix the end of the conduit to the furnace using the included conduit fitting B Attach the quick connect terminals on the wires exiting the power conduit assembly to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring termina...

Page 3: ...els including an airflow sensor Make sure flow sensor is clean and unobstructed Flow sensor is damaged for models including an airflow sensor Replace flow sensor available as replacement kit KIT160000 Flow sensor bypass assembly is damaged for models without an airflow sensor Replace flow sensor bypass assembly available as replacement kit KIT161000 One or more of the three airflow sensor contact ...

Page 4: ...ll be displayed after 10 seconds purifier will not operate until cause of error condition is rectified and purifier is reset An error code was registered in the purifier controls prior to the purifier being turned off The purifier controls may be reset during the 10 seconds in which the LED is flashing rapidly see the Reset Procedure on previous page if the problem persists follow the actions reco...

Reviews: