WIRING CONNECTIONS FOR FURNACES

3

WIRING CONNECTIONS FOR FAN COILS

4

A.

  Route the power conduit from the purifier to a knockout on the fan coil air 

handler that provides access to the incoming power wiring compartment. 

Affix the end of the conduit to the fan coil air handler using the included  

conduit fitting.

 

B.

  Remove the yellow and black primary wires from the fan coil air handler 

transformer terminals and connect the quick connect “piggyback” terminals 

of the quick connect kit leads exiting the air purifier power conduit assembly 

to the transformer terminals. Reconnect the yellow and black primary wires to 

their respective transformer terminals on the “piggyback” terminals. Attach the 

ground ring terminal on the third wire to the fan coil air handler chassis ground.  

Note:

  Power connections are to be made inside the fan coil wiring compartment 

per local electrical codes, and the two in-line fuses that are provided with 

the air purifier must be installed in the fan coil wiring compartment.  

For Fan Coil Purifiers: Black Lead − connect to L1; White Lead − connect 

to L2; Green Lead − connect to Appliance Ground (Chassis). 

A.

  Route the power conduit from the purifier to a 

knockout on the furnace that provides access 

to the EAC terminals on the furnace control 

board. Affix the end of the conduit to the 

furnace using the included conduit fitting. 

B.

  Attach the quick connect terminals on the 

wires exiting the power conduit assembly 

to the furnace EAC−1 and EAC−2 spade 

connections. Attach the ground ring terminal 

on the third wire to furnace chassis ground.   

 

Note:

  The Air Purifier should only be 

powered when airflow is present. 

The furnace control EAC spade 

connections, shown in image at left, 

provide power only when the furnace 

blower is operating. 

Sample Furnace Circuit Board

LHT

OFF

DLY

ON

OFF

W2

BL W

Y1
DHUM

GC

OM

24V

WW
1

Y/Y2

R

TEST/TWIN

HUM

1  2  

3

PL

T

A

CRDJ

0.5-AMP024 V AC

FUSE 3-AMP

SEC-1

SEC-2

PL

1

NEUTRAL-L2

1

EA C-2

BHT/CLR

BHI/LOR

PL3       

1

BL WR

COOL

SP ARE-1

SP ARE-2

1-AMP@115 V AC

EA C-1

PR-1

ID

R

HSI

R

ID

M

IHI/

LO

R

PL

2

1

HSI     HI    LO

S TATU

S

COD

EL

E

D

HI HEA

TL

O HE
AT

L1

Use terminals to connect the

power cord wires to the furnace

EAC-1 & 2, & ground terminals

CONDUIT CONNECTOR

TO SECURE POWER CORD

TO FURNACE CABINET

FURNACE CABINET

TO EAC-1

TO EA

C-2

TO CHASSIS

GROUND

Best Practice Tip: 

Avoid running high voltage along side 24v wiring.

Best Practice Tip: 

Avoid running high voltage along side 24v wiring.

Summary of Contents for DGAPA 1625 Series

Page 1: ...sory Kits are available if your installation does not match these recommendations see KIT160000 or KIT161000 Models DGAPAXX1625 DGAPAXX2025 DGAPAXX1620 DGAPAXX2020 DGAPAXX2420 There are three main mounting options for the air purifier product top mount bottom mount or side mount The location of the Air Purifier should be readily accessible Enough room should be provided for periodic replacement of...

Page 2: ...ound Chassis A Route the power conduit from the purifier to a knockout on the furnace that provides access to the EAC terminals on the furnace control board Affix the end of the conduit to the furnace using the included conduit fitting B Attach the quick connect terminals on the wires exiting the power conduit assembly to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring termina...

Page 3: ...els including an airflow sensor Make sure flow sensor is clean and unobstructed Flow sensor is damaged for models including an airflow sensor Replace flow sensor available as replacement kit KIT160000 Flow sensor bypass assembly is damaged for models without an airflow sensor Replace flow sensor bypass assembly available as replacement kit KIT161000 One or more of the three airflow sensor contact ...

Page 4: ...ll be displayed after 10 seconds purifier will not operate until cause of error condition is rectified and purifier is reset An error code was registered in the purifier controls prior to the purifier being turned off The purifier controls may be reset during the 10 seconds in which the LED is flashing rapidly see the Reset Procedure on previous page if the problem persists follow the actions reco...

Reviews: