25
Multipliers for Determining the Performance With Other Indoor Sections.
See notes on pg. 30.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
EDB
CFM
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Capacity
(MBtuh)
Total
Pwr
Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW†
38YZA030-31, 32 Outdoor Section With FX4(A,B)NF030 Indoor Section
65
900
12.1 11.1 2.02 14.9 13.7 2.06 17.9 16.4 2.10 21.4 19.0 2.15 25.4 23.1 2.22 30.0 30.0 2.30 35.4 35.4 2.43 41.2 41.2 2.54
1050
12.3 11.4 2.05 15.2 13.9 2.09 18.2 16.6 2.12 21.7 19.3 2.16 25.8 23.4 2.21 30.4 30.4 2.29 36.0 36.0 2.41 41.2 41.2 2.49
1200
12.6 11.6 2.09 15.4 14.2 2.12 18.5 16.8 2.14 22.0 19.5 2.18 26.1 23.7 2.23 30.8 30.8 2.30 36.4 36.4 2.40 41.2 41.2 2.46
70
900
11.8 10.9 2.11 14.7 13.5 2.16 17.7 16.2 2.21 21.1 18.8 2.26 25.0 22.8 2.33 29.5 29.5 2.42 34.9 34.9 2.54 40.8 40.8 2.68
1050
12.1 11.1 2.14 15.0 13.8 2.18 18.0 16.4 2.22 21.4 19.0 2.26 25.4 23.1 2.32 30.0 30.0 2.40 35.5 35.5 2.52 41.1 41.1 2.62
1200
12.3 11.3 2.18 15.2 14.0 2.22 18.2 16.6 2.24 21.7 19.3 2.28 25.7 23.4 2.33 30.4 30.4 2.41 35.9 35.9 2.52 41.3 41.3 2.60
75
900
11.5 10.6 2.21 14.5 13.3 2.26 17.5 16.0 2.32 20.9 18.5 2.37 24.7 22.5 2.44 29.2 29.2 2.54 34.3 34.3 2.66 40.3 40.3 2.81
1050
11.8 10.8 2.24 14.8 13.6 2.29 17.8 16.2 2.33 21.2 18.8 2.37 25.1 22.8 2.43 29.6 29.6 2.52 34.9 34.9 2.64 40.8 40.8 2.76
1200
12.0 11.0 2.28 15.0 13.8 2.32 18.0 16.4 2.35 21.5 19.1 2.39 25.4 23.1 2.44 30.0 30.0 2.52 35.4 35.4 2.63 41.1 41.1 2.74
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
CC5A/CD5AA
036
1.00
1.02
CK5PT
036
0.95
0.95
CD5AW
036
1.00
1.02
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CE3AA
036
0.99
1.03
CE3AA
036
0.94
0.97
CF5AA
036
1.00
1.02
CK3BA
036
0.95
0.94
CK3BA
036
1.00
1.00
CK5A/CK5BA
036
0.95
0.94
CK5A/CK5BA
036
1.00
1.00
CK5A/CK5BW
036
0.95
0.94
CK5A/CK5BT
036
1.00
1.00
CK5PA
036
0.95
0.94
CK5A/CK5BW
036
1.00
1.00
CK5PT
036
0.96
0.94
F(A,B)4(A,B)N(F,C)
036
1.01
1.04
CK5PW
036
0.95
0.94
FC4(B,C)NF
036
0.99
1.03
COILS + 58MVP060-14 VARIABLE SPEED FURNACE
FG3AAA
036
0.99
1.04
CC5A/CD5AA
036
0.99
0.95
FV4(A,B)NF
002
0.97
0.90
CK5A/CK5BA
036
0.99
0.95
003
0.97
0.92
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
FX4(A,B)NF
030
1.00
1.00
CC5A/CD5AA
036
0.99
0.95
036
0.97
0.97
CK5A/CK5BA
036
0.99
0.95
40FK(A,B)/
FK4(C,D)NF
002
0.97
0.90
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
003
0.97
0.93
CD5AW
036
0.99
0.95
COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE
CK5A/CK5BW
036
0.99
0.95
CE3AA
036
0.95
0.99
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
CK3BA
036
0.95
0.95
CD5AW
036
0.98
0.92
CK5A/CK5BA
036
0.96
0.95
CK5A/CK5BW
036
0.98
0.92
CK5PA
036
0.96
0.95
—
—
—
Heat pump heating performance continued