Multipliers for Determining the Performance With Other Indoor Sections.
See notes on pg. 22.
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
38YZA030-31, 32 Outdoor Section With FX4(A,B)NF030 Indoor Section
900
72
33.3
17.1
2.02
31.7
16.5
2.24
29.9
15.9
2.49
28.0
15.2
2.76
25.5
14.4
3.04
23.1
13.6
3.35
67
31.2
22.4
2.02
29.4
21.7
2.23
27.8
21.1
2.48
26.1
20.4
2.75
24.0
19.6
3.04
21.7
18.7
3.35
63††
29.3
21.9
2.01
27.7
21.2
2.23
26.2
20.6
2.47
24.6
19.9
2.75
22.9
19.1
3.05
20.9
18.3
3.39
62
29.0
27.5
2.01
27.4
26.7
2.22
26.1
25.9
2.47
24.7
24.7
2.75
23.0
23.0
3.04
21.0
21.0
3.35
57
28.5
28.5
2.00
27.1
27.1
2.22
25.9
25.9
2.47
24.4
24.4
2.74
22.8
22.8
3.04
21.0
21.0
3.35
1050
72
33.6
18.0
2.08
31.9
17.4
2.30
30.0
16.7
2.54
28.1
16.0
2.81
25.9
15.3
3.11
23.2
14.4
3.41
67
31.5
24.0
2.07
30.0
23.4
2.29
28.0
22.6
2.53
26.2
21.9
2.80
24.0
21.1
3.09
22.1
20.3
3.42
63††
29.7
23.4
2.06
27.9
22.6
2.28
26.4
22.0
2.53
24.8
21.3
2.80
23.0
20.5
3.10
20.9
19.6
3.43
62
29.6
29.4
2.06
28.1
28.1
2.28
26.8
26.8
2.53
25.1
25.1
2.80
23.6
23.6
3.10
21.4
21.4
3.40
57
29.6
29.6
2.06
28.0
28.0
2.28
26.6
26.6
2.53
25.1
25.1
2.80
23.4
23.4
3.09
21.4
21.4
3.40
1200
72
33.8
18.8
2.13
32.0
18.1
2.35
30.1
17.5
2.60
28.1
16.8
2.86
25.8
16.0
3.16
23.3
15.2
3.47
67
31.8
25.5
2.13
30.1
24.9
2.34
28.4
24.2
2.59
26.3
23.4
2.85
24.3
22.5
3.15
22.0
21.4
3.46
63††
29.9
24.8
2.12
28.1
24.0
2.33
26.5
23.3
2.58
24.9
22.6
2.85
23.0
21.7
3.15
21.0
20.7
3.48
62
30.3
30.3
2.12
28.8
28.8
2.34
27.4
27.4
2.59
25.7
25.7
2.85
23.9
23.9
3.15
22.0
22.0
3.47
57
30.3
30.3
2.12
28.7
28.7
2.34
27.2
27.2
2.58
25.6
25.6
2.85
23.8
23.8
3.15
21.7
21.7
3.46
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AA
036
1.00
1.01
CK5PT
036
0.98
0.89
CD5AW
036
1.00
1.01
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CE3AA
036
0.99
1.01
CE3AA
036
0.96
0.88
CF5AA
036
1.00
1.01
CK3BA
036
0.98
0.88
CK3BA
036
1.00
1.01
CK5A/CK5BA
036
0.98
0.88
CK5A/CK5BA
036
1.00
1.01
CK5PA
036
0.98
0.88
CK5A/CK5BT
036
1.00
1.01
CK5PT
036
0.98
0.88
CK5A/CK5BW
036
1.00
1.01
CK5PW
036
0.98
0.88
F(A,B)4(A,B)N(F,C)
036
0.99
1.03
COILS + 58MVP060-14 VARIABLE SPEED FURNACE
FC4(B,C)NF
036
0.99
1.03
CC5A/CD5AA
036
0.96
0.93
FG3AAA
036
0.99
1.01
CK5A/CK5BA
036
0.96
0.93
FV4(A,B)NF
002
1.00
0.90
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
003
1.00
0.91
CC5A/CD5AA
036
0.96
0.92
FX4(A,B)NF
030
1.00
1.00
CK5A/CK5BA
036
0.96
0.92
036
1.00
1.03
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
40FK(A,B)/
FK4(C,D)NF
002
1.00
0.90
CD5AW
036
0.96
0.93
003
1.00
0.91
CK5A/CK5BW
036
0.96
0.93
COILS + 58CV(A,X)070-12 VARIABLE SPEED FURNACE
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
CE3AA
036
0.96
0.90
CD5AW
036
0.97
0.91
CK5A/CK5BT
036
0.95
0.87
CK5A/CK5BW
036
0.97
0.91
CK5PA
036
0.98
0.89
—
—
—
Detailed cooling capacities* continued