NOTE

12 hours preheating is imperative after turn on the power 
switch. Please do not shut down the power when the unit
is supposed to stop running in 24h or shorter time. (This is 
to warm the crankcase heat box to avoid compulsive start 
of condenser.)

Pay attention not to block the air inlet and outlet.
Blocks may decrease the efficiency of the unit or startup the
protector, which will stop running.

3.    OPERATION RANGE

;YKZNKY_YZKSOTZNKLURRU]OTMZKSVKXGZ[XKLUXYGLK
GTJKLLKIZO\KUVKXGZOUT:NK3G^UVKXGZOUTZKSVKXGZ[XK
LUXZNKGOXIUTJOZOUTKX)UUROTM.KGZOTM

Cooling operation

Heating operating

Mode

Temperature

   Outdoor
temperature

     Room
temperature

   

-15

ć̚

27

ć

  

21

ć̚

32

ć

NOTE

1. If air conditioner is used outside the above conditions, it may         
cause the unit to function abnormally.

2. The phenomenon is normal that the surface of air conditioning 
may condense water when the relative larger humidity in room, 
please close the door and window.

3. Optimum performance will be achieved within these operating 
temperature range. 

4.The A-weighted sound pressure level is below 70 dB.

0

ć

̚

28

ć

Table 3-1

-15

ć̚

46

ć

3

4.1 Protection Equipment

 

The protection equipment may be activated in following conditions:

The air inlet or air outlet of outdoor unit is blocked.

Strong wind is Continuously blowing to the air outlet of the 
outdoor unit.

Too much dust and rubbish adhere to the dust filter in the  
indoor unit

The air outlet of indoor unit is choked

Ƶ

Cooling Operation

Heating Operation

 

 

 

 

When the protection equipment starts, please shut down the 

manual power switch, and restart operation after problem is

solved.

This Protection Equipment will enable the   Air Conditioner to stop
when the Air Conditio ner is to be directed running compulsively.

When the Protection Equipment is activated, the Operation 
Indicator still lights while the Air Conditioner is not running. But the 
Check Indicatior Lights. 

Ƶ

NOTE

4.2 About power cut

If power is cut during operation, stop all the operation immediately.

Power comes again. The lamp on the display panel of indoor unit 
flashes. And then unit will auto-restart.

Mishandling in operation:
If mishandling happens because of lighting or mobile wireless, 
please shut off the manual power switch, and turn on again, then
push the ON/OFF button.

4.3 Heating capacity

The heating operation is a heat-pump process that heat will be 
absorbed from outdoor air and released in doors. Once the 
outdoor temperature is decreased, heating capacity decreased 
corredpindingly.

Other heating equipment is suggested to be used together when 
outdoor temperature is too low.

In some extreme cold upland that buy another inddoor unit 
equipped electrical heater will obtain better performance.(Refer 
to indoor unit owner’s manual for details)

owner's manual

Current frequency

Local capacity of outdoor units

Total capacity requirements of 
outdoor units

Total  requirements of  outdoor units 
corrected capacity

Operating mode

Operating FAN speed and FAN grade

T2B/T2 average temperature

T3 pipe temperature 

T4 environment temperature

Inverter exhaust temperature

Non-inverter exhaust temperature
 (reserved)

Heat dissipator surface temperature
 (reserved)

Electronic expansion valve aperture

Inverter input current

Non-inverter input current

Exhaust pressure (reserved)

Priority mode

Indoor unit quantity

Working indoor unit quantity

Last fault or protection code

--

Normal display

Displayed Content

0--

1--

2--

3--

4--

5--

7--

8--

9--

0--

1--

2--

3--

4--

5--

6--

7--

8--

9--

6--

Sequence

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Table 2-2(22.4/26kW)

    

OPERATION AND PERFORMANCE

4

Summary of Contents for DC INVERTER FREE

Page 1: ...OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference DC INVERTER FREE ...

Page 2: ......

Page 3: ...om the air conditioner you purchased depend on model The actual shape shall prevail NOTE This air conditioner comprises an indoor unit outdoor unit and a connection pipe Outdoor unit Air outlet 1 2 3 4 Air inlet Fixing support Refrigerant pipe connector 1 2 3 4 Fig 1 Indoor unit 5 5 Connection pipe ...

Page 4: ...s service angent or similarly qualified person in order to avoid a hazard WARNING The safty precautions listed here are divided into two categories In either case important safty information is listed which must be read carefully CAUTION Failure to observe a caution may result in injury or damage to the equipment Failure to observe a warning may result in death The appliance shall be installed in ...

Page 5: ...pacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensure the effectiveness of machine and then try to open the indoor units at different time The outdoor unit window shades should be periodic cleaning in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components s...

Page 6: ...en the Air Conditioner is to be directed running compulsively When the Protection Equipment is activated the Operation Indicator still lights while the Air Conditioner is not running But the Check Indicatior Lights Ƶ NOTE 4 2 About power cut If power is cut during operation stop all the operation immediately Power comes again The lamp on the display panel of indoor unit flashes And then unit will ...

Page 7: ...operation the fan motor in the outdoor unit may stop running under high temperature During Fan Operation if other Indoor Units are running on Heating Mode the fan may stop in order to prevent sending heat wind 4 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automatically about 2 10 minutes and the...

Page 8: ...tion Outdoor input current protection COMM Fault between DSP and chip COMM Fault between communication chip and main chip P1 P2 P3 Compressor discharge high protection Outdoor condenser high temperature protection Evaporator high temperature protection Inverter module protection P4 P5 P6 23 24 Typhoon protection Recovery Mode Recoverable Recoverable Irrecoverable Irrecoverable Recoverable Recovera...

Page 9: ... is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing sound is heard when the s...

Page 10: ...nit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly...

Page 11: ... is pressed Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse o...