6.    FOLLOWING SYMPTOMS ARE NOT AIR

       CONDITIONER TROUBLES

Symptom 1: The system does not operate

Symptom 2: Change into the fan mode during

                      cooling mode       

                      

Symptom 3: White mist comes out of a unit

Sptom 4: Noise of air conditionerscooling 

The air conditioner does not start immediately after the ON/OFF 
button on the romote controller is pressed. 
If the operation lamp lights, the system is in normal condition.To 
prevent overloading of the compressor motor, the air 
conditioner starts 5 minutes  after  it  is turned ON.

If the operation lamp and the "

PRE-DEF indicator(cooling and 

heating type) or fan only indicator(cooling only type)"

 light, it 

means you choose the heating model, When just starting, if the 
compressor has not started, the indoor unit  appears "anti cold 
wind" protection because of its overlow outlet temperature.

In order to prevent the indoor evaporator frosting, the system 
will change into fan mode automatically, restore to the cooling 
mode after soon.

When the room temperature drops to the set temperature, the 
compressor goes off and the indoor unit changes to fan mode; 
when the temperature rises up, the compressor starts again. It 
is same in the heating mode.

Symptom 3.1: Indoor unit

 Symptom 3.2:  Indoor unit, outdoor unit

Symptom 4.1: Indoor unit

When humidity is high during cooling operation If the interior of 
an indoor unit is extremely contaminated, the temperature 
distribution inside a room becomes uneven. It is necessary to 
clean the interior of the indoor unit. Ask your dealer for details 
on cleaning the unit. This operation requires a qualified service 
erson

When the system is changed over to heating operation after 
defrost operation Moisture generated by defrost becomes 
steam and is exhausted.  

A continuous low "shah" sound is heard when the system is in 
cooling operation or at a stop. 
When the drain pump (optional accessories) is in operation,this 
noise is heard.

A "pishi-pishi" squeaking sound is heard when the system stops 
after heating operation. 
Expansion and contraction of plastic parts caused by 
temperature change make this noise. 

Symptom 4.2:  Indoor unit, outdoor unit 

A continuous low hissing sound is heard when the system is in 
operation. 
This is the sound of refrigerant gas flowing through both indoor 
and outdoor units. 

A hissing sound which is heard at the start or immediately after 
stopping operation or defrost operation. 
This is the noise of refrigerant caused by flow stop or flow 
change. 

Symptom 4.3: Outdoor unit 

When the tone of operating noise changes. 
This noise is caused by the change of frequency.

.

Symptom 5: Dust comes out of the unit 

Symptom 6: The units can give off odours

When the unit is used for the first time in a long time. 
This is because dust has gotten into the unit.

The unit can absorb the smell of rooms, furniture, cigarettes, 
etc., and then emit it again. 

Symptom 7: The outdoor unit fan does not       

                      spin.

During operation. The speed of the fan is controlled in order to 
optimize product operation. 

The operation lamp is flashing rapidly (twice every second)
This lamp is still flashing rapidly after turn off the power and turn 
on again.

Remote controller receives malfunction or the button does not 
work well.

A safety device such as a fuse, a breaker frequently actuates.

Obstacles and water enter the unit.

Water leaks from indoor unit.

Other malfunctions.

7.    TROUBLESHOOTING

If one of the following malfunctions occur, stop operation, shut 
off the power, and contact with your dealer.

If the system does not properly operate except the above 
mentioned cases or the above mentioned malfunctions is 
evident, investigate the system according to the following 
procedures. 

(see in Table 7-1)

7.1.      Troubles and causes of air conditioner

6

owner's manual

Summary of Contents for DC INVERTER FREE

Page 1: ...OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future reference DC INVERTER FREE ...

Page 2: ......

Page 3: ...om the air conditioner you purchased depend on model The actual shape shall prevail NOTE This air conditioner comprises an indoor unit outdoor unit and a connection pipe Outdoor unit Air outlet 1 2 3 4 Air inlet Fixing support Refrigerant pipe connector 1 2 3 4 Fig 1 Indoor unit 5 5 Connection pipe ...

Page 4: ...s service angent or similarly qualified person in order to avoid a hazard WARNING The safty precautions listed here are divided into two categories In either case important safty information is listed which must be read carefully CAUTION Failure to observe a caution may result in injury or damage to the equipment Failure to observe a warning may result in death The appliance shall be installed in ...

Page 5: ...pacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensure the effectiveness of machine and then try to open the indoor units at different time The outdoor unit window shades should be periodic cleaning in case of being jammed This window shapes is heat dissipation outlet of components if being jammed will cause the components s...

Page 6: ...en the Air Conditioner is to be directed running compulsively When the Protection Equipment is activated the Operation Indicator still lights while the Air Conditioner is not running But the Check Indicatior Lights Ƶ NOTE 4 2 About power cut If power is cut during operation stop all the operation immediately Power comes again The lamp on the display panel of indoor unit flashes And then unit will ...

Page 7: ...operation the fan motor in the outdoor unit may stop running under high temperature During Fan Operation if other Indoor Units are running on Heating Mode the fan may stop in order to prevent sending heat wind 4 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automatically about 2 10 minutes and the...

Page 8: ...tion Outdoor input current protection COMM Fault between DSP and chip COMM Fault between communication chip and main chip P1 P2 P3 Compressor discharge high protection Outdoor condenser high temperature protection Evaporator high temperature protection Inverter module protection P4 P5 P6 23 24 Typhoon protection Recovery Mode Recoverable Recoverable Irrecoverable Irrecoverable Recoverable Recovera...

Page 9: ... is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after heating operation Expansion and contraction of plastic parts caused by temperature change make this noise Symptom 4 2 Indoor unit outdoor unit A continuous low hissing sound is heard when the s...

Page 10: ...nit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly...

Page 11: ... is pressed Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse o...

Page 12: ......

Reviews: