PHYSICAL DATA

UNIT SIZE---SERIES, VOLTAGE

18---30

24---30

30---30

36---30

42---30

48---30

60---30

Operating Weight lb (kg)

207

(93.9)

204

(92.5)

211

(95.7)

252

(114.3)

239

(108.4)

314

(142.4)

361

(163.8)

Shipping Weight lb (kg)

218

(98.9)

236

(107.1)

222

(100.7)

287

(130.2)

250

(113.4)

348

(157.9)

395

(179.2)

Compressor Type

Scroll

REFRIGERANT

Freon

(R---22)

Control

TXV (R---22 Hard Shutoff)

Charge lb (kg)

7

(3.2)

7

(3.2)

6.8

(3.1)

8.1

(3.7)

9.5

(4.3)

13.5

(6.1)

16.5

(7.5)

COND FAN

Air Discharge

Vertical

Air Qty (CFM)

2233

2614

3167

3334

3334

4046

4046

Motor HP

1/12

1/10

1/5

1/8

1/8

1/4

1/4

Motor RPM

800

800

800

800

800

800

800

COND COIL

Face Area (Sq ft)

19.4

21.56

19.40

25.15

17.60

25.15

30.18

Fins per In.

20

20

20

20

20

20

20

Rows

1

1

1

1

2

2

2

Circuits

5

6

6

6

8

8

11

VALVE CONNECT. (In.) ID

Vapor

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

7/8”

Liquid

3/8”

REFRIGERANT TUBES* (in.)OD

Vapor (0---80 Ft Tube Length)

5/8”

5/8”

3/4”

3/4”

7/8”

7/8”

1---1/8

Liquid (0---80 Ft Tube Length)

3/8”

* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.

Note

: See unit Installation Instruction for proper installation.

VAPOR LINE SIZING AND COOLING CAPACITY LOSS

1--STAGE HEAT PUMP APPLICATIONS

LONG LINE APPLICATION: An application is considered ”Long
line” when the total equivalent tubing length exceeds 80 ft. (24.38

m) or when there is more than 20 ft. (6.09 m) vertical separation
between indoor and outdoor units. These applications require

additional accessories and system modifications for reliable system

operation. The maximum allowable total equivalent length is 250
ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m)

when outdoor unit is above indoor unit, and 60 ft. (18.29 m) when
the outdoor unit is below the indoor unit. Refer to Accessory

Usage Guideline below for required accessories. See Longline
Application

Guideline for required

piping

and

system

modifications. Also, refer to the table below for the acceptable

vapor tube diameters based on the total length to minimize the
cooling capacity loss.

Unit Nominal

Size (Btuh)

Acceptable

Vapor Line

Diameters

(In.) OD

Cooling Capacity Loss (%)

Total Equivalent Line Length ft. (m)

Standard Application

Long Line Application Requires Accessories

25

(7.62)

50

(15.24)

80

(24.38)

80+

(24.38+)

100

(30.48)

125

(38.10)

150

(45.72)

175

(53.34)

200

(60.96)

225

(68.58)

250

(76.2)

18,000

R---22 HP

5/8

0

1

1

1

2

3

3

4

5

5

6

3/4

0

0

0

0

0

1

1

1

1

2

2

24,000

R---22 HP

5/8

0

1

3

3

3

5

6

7

8

9

10

3/4

0

0

0

0

1

1

1

2

2

3

3

7/8

0

0

0

0

0

0

0

0

1

1

1

30,000

R---22 HP

5/8

1

3

5

5

6

8

10

11

13

15

17

3/4

0

1

1

1

2

3

3

4

5

5

6

7/8

0

0

0

0

1

1

1

2

2

2

3

36,000

R---22 HP

3/4

0

1

2

2

3

4

5

6

7

8

9

7/8

0

0

1

1

1

2

2

3

3

4

4

42,000

R---22 HP

3/4

1

2

3

3

4

5

7

8

9

10

11

7/8

0

1

1

1

2

2

3

4

4

5

5

48,000

R---22 HP

3/4

1

2

4

4

5

7

8

10

11

13

14

7/8

0

1

2

2

2

3

4

5

5

6

7

1---1/8

0

0

0

0

0

0

1

1

1

1

1

60,000

R---22 HP

7/8

1

2

3

3

4

5

7

8

9

10

11

1---1/8

0

0

1

1

1

1

2

2

2

3

3

Standard Length = 80 ft. (24.38 m) or less total equivalent length

Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines

Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See

Long Line Application Guidelines

25H

C

R

3C

Summary of Contents for Comfort 25HCR3C

Page 1: ...S Front seating service valves S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High and Low pressure switch S Filter drier S Balanced refrigeration system for maximu...

Page 2: ...ed capacity and efficiency Installation of this product should follow all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy e...

Page 3: ...ivalent length is 250 ft 76 2 m The maximum vertical separation is 200 ft 60 96 m when outdoor unit is above indoor unit and 60 ft 18 29 m when the outdoor unit is below the indoor unit Refer to Acces...

Page 4: ...use in zoning heat pump applications Outdoor temperature sensor is an accessory for all Carrier electronic thermostats except the non programmable air conditioner version and builder s thermostats It...

Page 5: ...ompressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all commercial...

Page 6: ...ectric heaters when outdoor air temperature drops below the second stage set point Usage Guideline Outdoor thermostat applications where electric heater is capable of 3 stage operation 15 Snow Stand C...

Page 7: ...G or smaller stranded wire for larger than 10 AWG is used consult applicable tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and service panel for voltage...

Page 8: ...8 DIMENSIONS 25HCR3C...

Page 9: ...8 11 7 14 6 17 6 20 5 23 4 kW 25HCR324C FA4CN F C 024 25HCR348C FC4DN F B 048 25HCR336C FC4DN F B 036 25HCR360C FC4DN F B 060 BASED ON INDOOR ENT AIR AT 70 F AND AT RATED CFM 25HCR318C FA4CN F C 018...

Page 10: ...2 58MVB060 14 CNRV 2417A 17 200 TDR TXV 14 50 12 50 17 400 3 66 9 900 2 44 8 2 58UVB060 14 CNRV 2417A 17 300 TXV 13 20 11 00 17 400 3 46 10 600 2 34 7 7 CSRH 2412A 17 300 TDR TXV 14 50 12 50 16 900 3...

Page 11: ...TDR TXV 14 50 11 70 23 600 3 72 14 100 2 54 8 7 58MVB060 14 CNRV 3017A 23 600 TDR TXV 14 50 11 70 23 600 3 72 14 100 2 54 8 7 58UVB060 14 CNRV 3017A 23 600 TXV 13 00 10 80 24 000 3 58 15 000 2 42 8 5...

Page 12: ...0 80 28 400 3 30 17 200 2 26 7 7 58CV A X 070 12 CNRV 3017A 28 600 TDR TXV 13 20 11 00 28 200 3 34 17 000 2 30 7 7 58CV A X 090 16 CNRV 3017A 28 400 TDR TXV 13 00 10 80 28 400 3 30 17 100 2 28 7 7 58M...

Page 13: ...3 00 10 80 35 400 3 36 20 800 2 44 8 2 58CV A X 135 22 CNRH 3617A 34 000 TDR TXV 13 20 11 00 35 400 3 38 20 800 2 46 8 2 58CV A X 155 22 CNRH 3617A 33 600 TDR TXV 13 00 10 80 35 400 3 30 21 000 2 40 8...

Page 14: ...0 2 40 7 7 58UVB100 20 CAR 4224A 40 000 TDR TXV 13 50 11 20 39 500 3 46 23 800 2 44 7 7 58CV A X 135 22 CAR 4224A 40 000 TDR TXV 13 50 11 20 39 500 3 46 23 800 2 44 7 7 58CV A X 155 22 CAR 4224A 39 50...

Page 15: ...22 CSRH 4212A 40 500 TDR TXV 13 20 11 00 40 500 3 50 24 200 2 40 7 7 58MVB040 14 CSRH 4212A 40 500 TDR TXV 13 50 11 20 40 500 3 54 24 200 2 42 7 7 58MVB060 14 CSRH 4212A 40 500 TDR TXV 13 20 11 00 40...

Page 16: ...29 600 2 58 8 3 58CV A X 135 22 CNRV 6024A 46 500 TDR TXV 13 50 11 20 45 500 3 40 29 400 2 60 8 3 58CV A X 155 22 CNRV 6024A 46 000 TDR TXV 13 50 11 20 46 000 3 32 29 800 2 56 8 2 58MVB120 20 CNRV 60...

Page 17: ...70 13 70 2 15 675 72 20 52 10 72 1 31 19 77 10 45 1 46 18 98 10 18 1 62 18 15 9 89 1 80 17 28 9 59 2 00 16 37 9 27 2 21 67 18 64 13 73 1 30 17 93 13 44 1 44 17 19 13 14 1 61 16 42 12 83 1 78 15 60 12...

Page 18: ...0 89 CAR 2414A 1 01 1 01 CAR 2417A 1 01 1 01 CAR 3014A 1 02 1 02 CAR 3017A 1 02 1 02 CNRF 2418A 1 01 1 01 CNRH 2417A 1 01 1 01 CNRH 3017A 1 02 1 02 CNRV 2414A 1 01 1 01 CNRV 2417A 1 01 1 01 CNRV 3014...

Page 19: ...99 0 99 58CV A X 070 12 CNRH 3617A 0 99 0 99 58CV A X 070 12 CNRV 3014A 0 99 0 99 58CV A X 070 12 CSRH 3012A 0 99 0 99 58CV A X 070 12 CSRH 3612A 1 01 1 00 58CV A X 070 12 CAR 3017A 0 99 0 97 58CV A...

Page 20: ...090 16 CNRH 4221A 0 99 0 96 58CV A X 090 16 CNRV 3617A 0 98 0 98 58CV A X 090 16 CSRH 3612A 0 98 0 95 58CV A X 090 16 CSRH 4212A 0 99 0 95 58CV A X 090 16 CAR 3621A 0 98 0 96 58CV A X 110 20 CAR 4221A...

Page 21: ...7 13 37 13 4 13 35 63 35 63 4 55 34 09 34 09 5 01 Cooling Indoor Model Capacity Power Furnace Model FC4DN F B 042 1 00 1 00 CSRH 4812A 1 01 1 03 FC4DN F B 048 1 02 1 01 FK4DN B F 003 0 98 0 96 FK4DN B...

Page 22: ...odel Capa city Power Furnace Model FC4DN F B 048 1 00 1 00 CSRH 6012A 0 98 0 98 FK4DNB006 1 01 0 95 FK4DNF005 0 99 0 95 CAR 4817A 0 94 0 92 58CV A X 090 16 CNRH 4821A 0 96 0 94 58CV A X 090 16 CNRH 60...

Page 23: ...4 60 68 38 37 73 5 01 65 49 36 67 5 47 62 53 35 60 5 98 59 43 34 48 6 54 56 21 33 32 7 14 67 64 95 49 52 4 53 62 36 48 43 4 94 59 68 47 33 5 40 56 94 46 20 5 91 54 09 45 03 6 46 51 12 43 81 7 06 63 6...

Page 24: ...16 96 16 96 1 50 16 39 16 39 1 48 75 525 7 00 6 44 1 24 8 98 8 25 1 32 11 19 10 20 1 40 13 72 12 19 1 49 16 47 14 99 1 61 18 71 18 71 1 70 19 76 19 76 1 74 19 86 19 86 1 74 600 7 15 6 58 1 26 9 14 8 4...

Page 25: ...1 00 0 96 CNRH 3017A 1 00 0 99 CNRV 2414A 1 00 0 96 CNRV 2417A 1 00 0 96 CNRV 3014A 1 00 0 99 CNRV 3017A 1 00 0 99 CSRH 2412A 1 00 0 96 CSRH 3012A 1 00 0 99 CAR 2414A 0 99 0 96 58CV A X 070 12 CAR 301...

Page 26: ...01 58CV A X 070 12 CSRH 3012A 0 98 1 00 58CV A X 070 12 CSRH 3612A 0 96 0 96 58CV A X 070 12 CAR 3017A 0 98 0 99 58CV A X 090 16 CAR 3617A 0 97 0 98 58CV A X 090 16 CNRH 3017A 0 98 0 99 58CV A X 090...

Page 27: ...8CV A X 090 16 CSRH 4212A 0 97 0 95 58CV A X 090 16 CAR 3621A 1 01 1 00 58CV A X 110 20 CAR 4221A 0 99 0 98 58CV A X 110 20 CNRH 3617A 1 01 1 01 58CV A X 110 20 CNRH 4221A 0 99 0 97 58CV A X 110 20 CN...

Page 28: ...RV 4221A 0 99 1 03 58CV A X 110 20 CNRV 4821A 0 99 0 98 58CV A X 110 20 CSRH 4212A 1 00 1 00 58CV A X 110 20 CSRH 4812A 1 00 0 99 58CV A X 110 20 CAR 4224A 0 98 1 01 58CV A X 135 22 CAR 4824A 0 99 0 9...

Page 29: ...6012A 0 98 0 99 CAR 4817A 0 96 0 99 58CV A X 090 16 CNRH 4821A 0 98 1 02 58CV A X 090 16 CNRH 6024A 0 98 1 02 58CV A X 090 16 CSRH 4812A 0 98 1 01 58CV A X 090 16 CSRH 6012A 0 98 1 00 58CV A X 090 16...

Page 30: ...5 67 83 67 83 5 29 68 80 68 80 5 30 2250 26 22 24 12 4 21 31 81 29 23 4 35 37 85 34 51 4 50 44 65 39 66 4 67 52 37 47 66 4 87 59 78 59 78 5 03 64 71 64 71 5 17 64 66 64 66 5 14 75 1750 24 93 22 93 4 2...

Page 31: ...totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be corrosion resistant Fan blades will be statically and dynamically balanced Condenser fan openin...

Page 32: ...W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 25HCR3C 2PD Replaces 25HCR3C 1PD...

Reviews: