background image

5

ACCESSORIES

ORDER NUMBER

DESCRIPTION

18---30

24---30

30---30

36---31

42---31

60---30

KAACH1601AAA

CRKC HTR KIT

X

KAACH1701AAA

CRKC HTR KIT

X

X

X

X

STANDARD

CRKC HTR KIT

S

KSACY0101AAA

CYCLE PROTR KIT

X

X

X

X

X

X

KAAFT0101AAA

FRZ THERM KIT

X

X

X

X

X

X

KSAHS1701AAA

HARD START KIT

X

X

X

X

X

X

KHAIR0101AAA

ISLN RELAY KIT

X

X

X

X

X

X

KAACS0201PTC

KIT PTC

X

X

X

X

X

X

KSALA0301410

LOW AMBIENT KIT

X

X

X

X

X

X

HC32GE234

MOTOR,FAN

X

HC34GE240

MOTOR,FAN

X

X

X

HC38GE219

MOTOR,FAN

X

HC40GE228

MOTOR,FAN

X

KSALA0601AAA

{

MOTORMASTER KIT

X

X

X

X

X

X

KHAOT0201SEC

OUTDR THERM KIT

X

X

X

X

X

X

KHAOT0301FST

OUTDR THERM KIT

X

X

X

X

X

X

KHASS0606MPK*

SNOW STAND KIT

X

X

X

X

X

X

KHALS0401LLS

SOL VALVE KIT

X

X

X

X

X

X

KSASH0601COP

SOUND BLKT KIT

X

X

X

X

X

KSASH2101COP

SOUND BLKT KIT

X

KSASF0101AAA

SPRT FEET KIT

X

X

X

X

X

X

KAATD0101TDR

TIME DELAY KIT

X

X

X

X

X

X

KSATX0201PUR

TXV KIT

X

X

X

KSATX0301PUR

TXV KIT

X

X

KSATX0501PUR

TXV KIT

X

x = Accessory S = Standard

* Available through RCD

{

Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, isolation relay, hard

shut---off TXV or liquid line solenoid valve.

ACCESSORY THERMOSTATS

PART NUMBER

PROGRAM

GAS

ELECTRIC

HEAT PUMP

HEAT

COOL

TC---PHP01

5---2 Day

3

2

TC---NHP01

NP

3

2

TCSNHP01

NP

2

1

TB---PHP01

5---2 Day

2

1

TB---NHP01

NP

2

1

THERMOSTAT ACCESSORIES

PART NUMBER

BRIEF DESCRIPTION

THERMOSTATS USED WITH

TSTATXXCNV10‡

Thermostat Conversion Kit (4 to 5 wire) --- 10 pack

All Carrier branded thermostats

TX---LBP01

Large Decorative Backplate

TP---Pxx, TP---Nxx, TC---Pxx

TX---MBP01

Medium Decorative Backplate

TC---Nxx, TB---Pxx

TX---SBP01

Small Decorative Backplate

TB---Nxx

25H

C

D

4

Summary of Contents for Comfort 25HCD4

Page 1: ...ratings information INDUSTRY LEADING FEATURES BENEFITS Efficiency S 14 SEER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 69 dB...

Page 2: ...all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life Use of the AHRI Certified TM Mark...

Page 3: ...Cooling Capacity Losses Puronr Refrigerant 1 Stage Heat Pump Applications Unit Nominal Size Btuh Maximum Liquid Line Diameters In OD Vapor Line Diameters In OD Cooling Capacity Loss Total Equivalent...

Page 4: ...0 250 250 250 250 24000 HP with Puron 3 8 250 250 250 250 250 250 250 30000 HP with Puron 3 8 250 250 250 250 250 250 250 36000 HP with Puron 3 8 250 250 250 250 250 250 250 42000 HP with Puron 3 8 25...

Page 5: ...X X X X X KSASH2101COP SOUND BLKT KIT X KSASF0101AAA SPRT FEET KIT X X X X X X KAATD0101TDR TIME DELAY KIT X X X X X X KSATX0201PUR TXV KIT X X X KSATX0301PUR TXV KIT X X KSATX0501PUR TXV KIT X x Acce...

Page 6: ...mproves compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all c...

Page 7: ...allow for drainage from unit base Usage Guideline Suggested in the following applications Heat pump installations in heavy snowfall areas Heat pump installations in snow drift locations Heat pump ins...

Page 8: ...TE Control circuit is 24 V on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection Complies...

Page 9: ...9 DIMENSIONS ENGLISH 25HCD4...

Page 10: ...10 DIMENSIONS SI 25HCD4...

Page 11: ...Y MBTUH 25HCD424A30 FB4CNF030 25HCD442A30 FB4CNF048 25HCD430A30 FB4CNF030 25HCD448A30 FB4CNF060 25HCD436A30 FB4CNF036 25HCD460A30 FX4DNF061 25HCD418A30 FB4CNF018 23 3 17 8 12 2 6 7 1 1 4 4 10 0 15 6 2...

Page 12: ...2 24 609 6 Service 6 152 4 12 304 8 24 609 6 Service 24 609 6 Service 24 609 6 Service Note Numbers in mm 18 457 2 18 457 2 12 304 8 IMPORTANT When installing multiple units in an alcove roof well or...

Page 13: ...TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD436 31 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD442 30 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD448 30 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25H...

Page 14: ...r fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be c...

Page 15: ...rconnecting refrigerant tube lengths greater than 80 ft 23 4 m and or elevation differences between indoor and outdoor units greater than 20 ft 6 1 m consult Residential Piping and Longline Guideline...

Page 16: ...rp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 02 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 25HC...

Reviews: