TESTED AHRI COMBINATION RATINGS

NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory

www.ahridirectory.org

Additional ratings and system combinations can be accessed via the Carrier database at:

www.MyCarrierRatings.com

For performance data at specific application &/or design conditions with various indoor unit combinations, the
equipment performance calculator can be accessed at :

http://rpmob.wrightsoft.com/

Model

Number

Coil Model Number

Furnace

Model Number

Cooling

Capacity

EER

SEER

High Temp

HSPF

Low Temp

E

Capacity

E COP

H

Capacity

H COP

25HCD418---30

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

25HCD424---30

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

25HCD430---30

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

25HCD436---31

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

25HCD442---30

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

25HCD448---30

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

25HCD460---30

TBA

TBA

TBA

TBA

14.0

TBD

TBA

TBA

TBA

TBA

*

AHRI = Air Conditioning, Heating & Refrigeration Institute

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:

Cooling Standard:

80

_

F (27

_

C) db 67

_

F (19

_

C) wb indoor entering air temperature and 95

_

F (35

_

C) db air entering outdoor unit.

High---Temp Heating Standard:

70

_

F (21

_

C) db indoor entering air temperature and 47

_

F (8

_

C) db 43° F (6

_

C) wb air entering outdoor unit.

Low---Temp Heating Standard:

70

_

F (21

_

C) db indoor entering air temperature and 17

_

F (---8

_

C) db 15° F (---9

_

C) wb air entering outdoor unit.

COP

— Coefficient of Performance

EER

— Energy Efficiency Ratio

HSPF

— Heating Seasonal Performance Factor

SEER

— Seasonal Energy Efficiency Ratio

25

HCD4

Summary of Contents for Comfort 25HCD4

Page 1: ...ratings information INDUSTRY LEADING FEATURES BENEFITS Efficiency S 14 SEER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 69 dB...

Page 2: ...all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life Use of the AHRI Certified TM Mark...

Page 3: ...Cooling Capacity Losses Puronr Refrigerant 1 Stage Heat Pump Applications Unit Nominal Size Btuh Maximum Liquid Line Diameters In OD Vapor Line Diameters In OD Cooling Capacity Loss Total Equivalent...

Page 4: ...0 250 250 250 250 24000 HP with Puron 3 8 250 250 250 250 250 250 250 30000 HP with Puron 3 8 250 250 250 250 250 250 250 36000 HP with Puron 3 8 250 250 250 250 250 250 250 42000 HP with Puron 3 8 25...

Page 5: ...X X X X X KSASH2101COP SOUND BLKT KIT X KSASF0101AAA SPRT FEET KIT X X X X X X KAATD0101TDR TIME DELAY KIT X X X X X X KSATX0201PUR TXV KIT X X X KSATX0301PUR TXV KIT X X KSATX0501PUR TXV KIT X x Acce...

Page 6: ...mproves compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested in all c...

Page 7: ...allow for drainage from unit base Usage Guideline Suggested in the following applications Heat pump installations in heavy snowfall areas Heat pump installations in snow drift locations Heat pump ins...

Page 8: ...TE Control circuit is 24 V on all units and requires external power source Copper wire must be used from service disconnect to unit All motors compressors contain internal overload protection Complies...

Page 9: ...9 DIMENSIONS ENGLISH 25HCD4...

Page 10: ...10 DIMENSIONS SI 25HCD4...

Page 11: ...Y MBTUH 25HCD424A30 FB4CNF030 25HCD442A30 FB4CNF048 25HCD430A30 FB4CNF030 25HCD448A30 FB4CNF060 25HCD436A30 FB4CNF036 25HCD460A30 FX4DNF061 25HCD418A30 FB4CNF018 23 3 17 8 12 2 6 7 1 1 4 4 10 0 15 6 2...

Page 12: ...2 24 609 6 Service 6 152 4 12 304 8 24 609 6 Service 24 609 6 Service 24 609 6 Service Note Numbers in mm 18 457 2 18 457 2 12 304 8 IMPORTANT When installing multiple units in an alcove roof well or...

Page 13: ...TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD436 31 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD442 30 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25HCD448 30 TBA TBA TBA TBA 14 0 TBD TBA TBA TBA TBA 25H...

Page 14: ...r fan will be direct drive propeller type discharging air upward Condenser fan motors will be totally enclosed 1 phase type with class B insulation and permanently lubricated bearings Shafts will be c...

Page 15: ...rconnecting refrigerant tube lengths greater than 80 ft 23 4 m and or elevation differences between indoor and outdoor units greater than 20 ft 6 1 m consult Residential Piping and Longline Guideline...

Page 16: ...rp S 7310 W Morris St S Indianapolis IN 46231 Edition Date 02 13 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No 25HC...

Reviews: