background image

CNPVU

CNRVU

Installation Instructions

Uncased Coils

Upflow - Downflow

Heating - Cooling

NOTE

:  Read the entire instruction manual before starting the

installation.

TABLE OF CONTENTS

PAGE

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INSTALLATION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Procedure 1 — Inspect Equipment

2

. . . . . . . . . . . . . . . . . . . .

Procedure 2 — Select Installation 

3

. . . . . . . . . . . . . . . . . . . .

Procedure 3 — Installation of Evaporator Coil

4

. . . . . . . . . . .

Procedure 4 — Connect Refrigerant Piping

6

. . . . . . . . . . . . .

Procedure 5 — Connect Refrigerant Liquid

                          and Suction Lines

6

. . . . . . . . . . . . . . . . . . . .

Procedure 6 — Condensate Drain Line Connection

7

. . . . . . .

Procedure 7 — Humidifier Application

8

. . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified

installer or agency must use factory

authorized kits or accessories

when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Use quenching cloth for brazing operations.

Have fire extinguisher available. Read these instructions

thoroughly and follow all warning or cautions included in literature

and attached to the unit. Consult local building codes and the

current editions of the National Electrical Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical

Code CSA C22.1.
Recognize safety information. When you see this symbol 

 on

the unit and in instructions or manuals, be alert to the potential for

personal injury. Understand the signal words 

DANGER

,

WARNING

CAUTION

, and 

NOTE

. These words are used with

the safety

alert symbol. 

DANGER

 identifies the most serious

hazards which 

will 

result in severe personal injury or death.

WARNING

 signifies hazards which 

could 

result in personal injury

or death. 

CAUTION

 is used to identify unsafe practices which

may 

result in minor personal injury or product and property

damage. 

NOTE

 is used to highlight suggestions which 

will 

result

in enhanced installation, reliability, or operation.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one disconnect

switch. Tag disconnect switch with a suitable warning label.

Turn off accessory heater power if applicable.

!

WARNING

UNIT OR PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in product or

property damage.
This coil contains Nitrogen precharge of 15 PSI. Release of

this pressure through the center of the rubber plugs is

required before removing the plugs.

CAUTION

!

CUT HAZARD

Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and

wear appropriate protective clothing and gloves when

handling parts.

CAUTION

!

IMPORTANT

: Nitrogen can leak out through the hole that the

needle pierced in the plugs. This does not indicate a leaking coil
nor warrant return of the coil.

INTRODUCTION

Use this instruction manual to install indoor coils on upflow or

downflow furnaces. (See Fig. 1.) Do not install coil in horizontal

position. Models CNPVU/CNRVU have factory

installed

thermostatic expansion valves (TXVs). CNPVU models are used

with Puron

r

 refrigerant (R410A) systems and CNRVU models are

used with R

22 systems.

Summary of Contents for CNPVU1814ACA

Page 1: ...he potential for personal injury Understand the signal words DANGER WARNING CAUTION and NOTE These words are used with the safety alert symbol DANGER identifies the most serious hazards which will res...

Page 2: ...ith R 22 refrigerant Use only with outdoor units designed for R 22 NOTE All TXVs have preset superheat settings and are not field adjustable Airflow Airflow amount and distribution are vital to adequa...

Page 3: ...VU37171A C T L A 3 19 1 8 16 3 4 19 3 8 16 1 4 3 8 7 8 KCAKC3201ECC CNPVU4221A C T L A 3 1 2 19 1 8 20 1 4 19 3 8 19 5 8 3 8 7 8 KCAKC2801ECC CNPVU4324A C T L A 3 1 2 19 1 8 23 3 4 19 3 8 23 1 8 3 8 7...

Page 4: ...remature failure CAUTION CUT HAZARD Failure to follow this caution may result in personal injury Sheet metal parts may have sharp edges or burrs Use care and wear appropriate protective clothing and g...

Page 5: ...old N coil from casing and discard coil 3 Slide new N coil into casing 4 Cut holes for liquid suction and drain connections in the existing header panel Use new header plate supplied with coil as tem...

Page 6: ...t seal and better installation presentation 7 Seal all joints to create air tight seal using locally approved materials IMPORTANT Locate caution label stapled to installation instructions Attach to ri...

Page 7: ...fabricated secondary condensate pan under the entire unit CAUTION The coil is designed to dispose of accumulated water through built in condensate drain fittings It is recommended that PVC fittings b...

Page 8: ...removed from their casing and applied dir ectly into the plenum affix this Caution Label to the right side of the plenum enclosure This is needed only in cases where the humidifier is not installed w...

Reviews: