22
INSTALLATION OF WIRED ROOM CONTROLLER
14.3 Installation Diagram of wired control
1. Wired remote controller
structure size figure
2. Wiring Principle Sketch:
INSTALLATION PROCEDURE
4.Back cover installation
Buckling position Back cover
Straight head Front cover
screwdriver
5.Wiring :
B. Shielded wiring
Embedded 86 electrician box wiring
CAUTION
Avoid the water enter into the wired remote controller, use trap and putty to seal the connectors of
wires during wiring installation. (Fig.10)
When under installation, reserve certain length of the connecting wire for convenient to take down
the wired remote controller while during maintenance.
CAUTION
6.Front cover installation
Fig.11 Fig.12
1. Use straight head screwdriver to insert into the buckling position in the bottom of wire
controller, and spin the screwdriver to take down the back cover. (Pay attention to
spinning direction, otherwise will damage the back cover!) (Fig.5)
2. Use three GB950-86 M4X20 screws to directly install the back cover on the wall. (Fig.6)
3. Use two M4X25 GB823-88screws to install the back cover on the 86 electrician box,
and use one GB950-86 M4X20 screws for fixing on the wall. (Fig.7.1)
4. Adjust the length of two plastic screw bars in the accessory to be standard length
from the electrical box screw bar to the wall. Make sure when install the screw bar to
the electrical box screw bar, make it as flat as the wall. (Fig.7.2)
5. Use cross head screws to fix the wire controller bottom cover in the electric control
box through the screw bar. Make sure the wire controller bottom cover is on the same
level after installation, and then install the wire controller back to the bottom cover.
6. Over fasten the screw will lead to deformation of back cover.
CAUTION
After adjusting the front cover and then buckle the
front cover; avoid clamping the communication
switching wire during installation. (Fig.11)
Correct install the back cover and firmly buckle the
front cover and back cover, otherwise will make the
front cover drop off. (Fig. 12)
.
60
46
44
47
14
10
12
19
84
Figure A
Fig
ur
e
A
120
20
120
Unit : mm
INDOOR MAIN
BOARD
DISPLAY
PANEL
3-cores shield wire
INDOOR UNIT
INDOOR UNIT
CONNECTOR
WHITE
RED
2-cores wire
4-cores wire
R
ED
B
LA
C
K
YE
LL
O
W
B
R
O
W
N
WIRED REMOTE CONTROLLER
1) This wired remote controller is compatible with the indoor unit
of V4+ heat recycling 3-pipe system and V4+ 2-pipe system.
2) Please do not connect the wired remote controller and a CCM.
to the same X, Y PORT, otherwise it will lead to conflict.
CAUTION
Screw hole fixed on
the wall, use one
GB950-86 M4X20
Fig. (7.2)
Screw hole installed on
the wall, use three
GB950-86 M4X20
Fig. (5)
Fig. (6)
Screw hole installed
on 86 Electrician box,
use two M4X25
GB823-88
A. Wiring, three out letting positions
Cutting place
of top side wire
outlet
Cutting place
of upper
left wire outlet
Cutting place
of left middle
side wire outlet
Fig. (8)
Top side
wire outlet
Upper left
wire outlet
Left
middle
side wire
outlet
Fig. (7.1)
86 Electrician box
Back cover
Signal
switching
wires
86 Electrician
box
Wiring
hole
Wall hole and wiring hole
Diameter
:
Φ8 ~ Φ10
Putty
Trap
Trap
Putty
Putty
Trap
Summary of Contents for ClassiCOOL 53KDHT60N-518
Page 57: ......