CB62000

Installation Instructions

Humidistat

NOTE

: Read the entire instruction manual before starting the

installation.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury or property

damage. Consult a qualified installer, service agency or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings and cautions

included in literature and attached to the unit. Consult local
building codes and the current edition of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.

Recognize safety information. When you see this symbol

on

the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the

safety--alert symbol.

DANGER

identifies the most serious hazards,

which

will

result in severe personal injury or death.

WARNING

signifies hazards, which

could

result in personal injury or death.

CAUTION

is used to identify unsafe practices, which

may

result

in minor personal injury or product and property damage.

NOTE

is used to highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one disconnect

switch. Lock out and tag switch with a suitable warning label.

!

WARNING

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.
Unit must not be installed where freezing temperatures could

occur. Do not install unit on the furnace or fan coil jacket. Do

not install unit where ends of cooling coil could restrict

airflow to the humidifier. Condensation damage could occur if

home has closed--off, unheated rooms.

CAUTION

!

INSTALLATION

INSTRUCTIONS FOR DUCT MOUNTING

(See next page for wall mounting)

Inside of Duct

Outside of Duct

A13349

Fig. 1 -- Duct--Mount Diagram

1. Turn OFF power to the humidifier.
2. The humidistat has been pre--assembled for wall mounting.

Duct mount applications will need adaptation, refer to Fig.
1.

3. Select a location on the return air duct to mount the hu-

midistat. IMPORTANT! IT MUST BE PLACED UP-
STREAM FROM THE HUMIDIFIER.

4. Using the mounting template (Fig. 3) on Pg. 3, drill the four

mounting holes using a 5/64” (2mm) drill bit. Next drill the

holes for the Humidistat Cutout Area using a 3/8” (10mm)
drill bit. Finally, drill the hole for the wire leads using a 1/4”
(7mm) drill bit.

5. Using tin snips, carefully cut out the opening for the hu-

midistat. BE CAREFUL! METAL EDGES ARE SHARP.

Drill four corner holes to start the cut.

6. Carefully run the wire leads through the lead wire hole and

position the humidistat in the humidistat opening.

7. Fasten the humidistat to the duct with screws provided.
8. Remove the paper backing from the humidistat label and

apply to the face of the mounting base. Attach the knob to
the humidistat control shaft. Turn knob to the “off” position.

9. Join the wire leads to the thermostat cable using the wire

connectors provided. (Refer to humidifier installation in-
structions for system wiring options.)