• Before performing any maintenance on the gen-

erator, disconnect its battery cables to prevent 
accidental start-up. Disconnect the cable from the 
battery post indicated by a NEGATIVE, NEG or (–) 
first. Reconnect that cable last.

• Never use the generator or any of its parts as a 

step. Stepping on the unit can stress and break 
parts, and may result in dangerous operating con-
ditions from leaking exhaust gases, fuel leakage, 
oil leakage, etc.

 ELECTRICAL HAZARDS 

• All generators covered by this manual produce 

dangerous electrical voltages and can cause fatal 
electrical shock. Utility power delivers extremely 
high and dangerous voltages to the transfer switch 
as well as the standby generator. Avoid contact 
with bare wires, terminals, connections, etc., on 
the generator as well as the transfer switch, if 
applicable. Ensure all appropriate covers, guards 
and barriers are in place before operating the gen-
erator. If work must be done around an operating 
unit, stand on an insulated, dry surface to reduce 
shock hazard.

• Do not handle any kind of electrical device while 

standing in water, while barefoot, or while hands or 
feet are wet. DANGEROUS ELECTRICAL SHOCK 
MAY RESULT.

•  If personnel must stand on metal or concrete while 

installing, operating, servicing, adjusting or repair-
ing this equipment, place insulative mats over a 
dry wooden platform. Work on the equipment only 
while standing on such insulative mats.

• The National Electrical Code (NEC) requires the 

frame and external electrically conductive parts 
of the generator to be connected to an approved 
earth ground. This grounding will help prevent 
dangerous electrical shock that might be caused 
by a ground fault condition in the generator set or 
by static electricity. Never disconnect the ground 
wire.

• Wire gauge sizes of electrical wiring, cables and 

cord sets must be adequate to handle the maxi-
mum electrical current (ampacity) to which they 
will be subjected.

• Before installing or servicing this (and related) 

equipment, make sure that all power voltage 
supplies are positively turned off at their source. 
Failure to do so will result in hazardous and pos-
sibly fatal electrical shock.

• Connecting this unit to an electrical system nor-

mally supplied by an electric utility shall be by 
means of a transfer switch so as to isolate the 
generator electric system from the electric utility 
distribution system when the generator is operat-
ing. Failure to isolate the two electric system power 
sources from each other by such means will result 
in damage to the generator and may also result 
in injury or death to utility power workers due to 
backfeed of electrical energy.

• Generators installed with an automatic transfer 

switch will crank and start automatically when 
normal (utility) source voltage is removed or is 
below an acceptable preset level. To prevent such 
automatic start-up and possible injury to person-
nel, disable the generator’s automatic start circuit 
(battery cables, etc.) before working on or around 
the unit. Then, place a “Do Not Operate” tag on 
the generator control panel and on the transfer 
switch.

•  In case of accident caused by electric shock, imme-

diately shut down the source of electrical power. 
If this is not possible, attempt to free the victim 
from the live conductor. AVOID DIRECT CONTACT 
WITH THE VICTIM. Use a nonconducting imple-
ment, such as a dry rope or board, to free the vic-
tim from the live conductor. If the victim is uncon-
scious, apply first aid and get immediate medical 
help.

• Never wear jewelry when working on this equip-

ment. Jewelry can conduct electricity resulting in 
electric shock, or may get caught in moving com-
ponents causing injury.

 FIRE HAZARDS 

• Keep a fire extinguisher near the generator at all 

times. Do NOT use any carbon tetra-chloride type 
extinguisher. Its fumes are toxic, and the liquid 
can deteriorate wiring insulation. Keep the extin-
guisher properly charged and be familiar with its 
use. If there are any questions pertaining to fire 
extinguishers, consult the local fire department.

 EXPLOSION HAZARDS 

• Properly ventilate any room or building housing 

the generator to prevent build-up of explosive gas.

•  Do not smoke around the generator. Wipe up any 

fuel or oil spills immediately. Ensure that no com-
bustible materials are left in the generator com-
partment, or on or near the generator, as FIRE or 
EXPLOSION may result. Keep the area surround-
ing the generator clean and free from debris.

• These generator sets may operate using one of 

several types of fuels. All fuel types are potentially 
FLAMMABLE and/or EXPLOSIVE and should be 
handled with care. Comply with all laws regulat-
ing the storage and handling of fuels. Inspect the 
unit’s fuel system frequently and correct any leaks 
immediately. Fuel supply lines must be prop-
erly installed, purged and leak tested according to 
applicable fuel-gas codes before placing this equip-
ment into service.

• Diesel fuels are highly FLAMMABLE. Gaseous 

fluids such as natural gas and liquid propane 
(LP) gas are extremely EXPLOSIVE. Natural gas 
is lighter than air, and LP gas is heavier than air; 
install leak detectors accordingly.

1-2

Standby Generator Sets

Important Safety Instructions

Safety 002  Re

v. 0  09/05

Summary of Contents for ASPDA1CCL045

Page 1: ...rial Number 2 4L 45kW Models ASPDS1CCL045 ASPDA1CCL045 Not intended for use in critical life support applications ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION DEADLY EXHAUST...

Page 2: ...1 Initial Inspection for Genset Start up 8 1 Start up Check List 8 2 OPERATION 9 1 Generator Control and Operation 9 1 Operating Unit with Automatic Transfer Switch 9 1 MAINTENANCE 10 1 Maintenance P...

Page 3: ...installed operated and serviced in accordance with the manufacturer s instructions and recommendations Following installation do nothing that might render the unit unsafe or in noncompliance with the...

Page 4: ...will result in damage to the generator and may also result in injury or death to utility power workers due to backfeed of electrical energy Generators installed with an automatic transfer switch will...

Page 5: ...ion hazard This symbol points out potential fire hazard This symbol points out potential electrical shock hazard The operator is responsible for proper and safe use of the equipment The manufacturer s...

Page 6: ...the end of this manual or to the data label affixed to the unit Generator Model and Serial Number This number is the key to numerous engineering and manufacturing details pertaining to your unit Alway...

Page 7: ...e failure NOTE For temperatures below 32 F it is strongly recom mended to use the optional Cold Weather Start Kit part number listed in the Specification Section The oil grade for temperatures below 3...

Page 8: ...g cranking and operating Should oil pressure drop below the 8 psi range switch contacts close and the engine shuts down The unit should not be restarted until oil is added and the AUTO OFF MANUAL swit...

Page 9: ...and local codes To reduce gas pressure to a safe level before the gas enters a building a primary regulator is needed The natural gas supplier may or may not supply such a regulator It is the responsi...

Page 10: ...ectronic Frequency Regulation Isochronous Steady State Regulation 0 25 Engine Lubrication System Type of Oil Pump Gear Oil Filter Full Flow Spin on Cartridge Crankcase Oil Capacity 4 U S qts COOLING S...

Page 11: ...pe for configuration 10 Reverse the procedure to convert back to natural gas 11 The Dip switch inside the control panel must be in the LP or NG position when switching to differ ent fuels Figure 6 2 R...

Page 12: ...oduced in the stator power windings These windings were con nected at the factory to the main circuit breaker as shown in Figure 7 1 The rated voltage between each circuit breaker ter minal is 240V Th...

Page 13: ...fications and Engine Oil Recommendations NOTE This engine is shipped from the manufacturer with break in oil This oil should be changed after 30 hours of operation PRIOR TO INITIAL START UP Prior to i...

Page 14: ...ssary for long fuel lines Open the generator main line circuit breaker Connect a manometer to the gas line and record the static pressure It must be as listed in the Specifications Insert the fuse int...

Page 15: ...WITCH If the generator has been installed with an automatic transfer switch such as an RTS HTS or GTS type transfer switch the engine may be started and stopped automatically or manually NOTE Refer to...

Page 16: ...bstructed for contin ued proper operation This includes such obstruc tions as high grass weeds brush leaves and snow Without sufficient cooling and ventilating air flow the engine generator quickly ov...

Page 17: ...damage deterioration leaks etc Correct any discrepancies found Check hose clamps for tightness CHECK ENGINE COOLANT LEVEL See Checking Fluid Levels PERFORM VISUAL INSPECTION Complete a thorough visua...

Page 18: ...for oil leaks CHANGING THE ENGINE AIR CLEANER To replace the engine air cleaner remove the air cleaner cover and replace the air filter making sure it is positioned properly before reattaching the co...

Page 19: ...on which can shatter the battery causing blindness or other serious injury BATTERY MAINTENANCE The battery should be inspected per the Scheduled Maintenance section The following procedure should be f...

Page 20: ...tery cable to prevent an over current condition from burning out sensitive control panel components and circuits Following all maintenance reverse these steps to insure the unit is returned to standby...

Page 21: ...gas engine driven units Tighten connections as necessary 6 Check the air inlets and outlets for debris Clean as necessary 7 Check the battery electrolyte level if accessible Adjust as necessary 8 Chec...

Page 22: ...d exercise the unit at full rated load use a load bank if the site load is not enough for at least 2 hours looking for leaks loose connections or components and abnormal operating conditions Correct a...

Page 23: ...commended in SPECIFICATIONS Engine starts then shuts down 1 Engine oil level is low 1 Check oil and add oil as needed 2 Engine is overheated 2 Check cooling system for leaks 3 Defective Low Oil Pressu...

Page 24: ...Standby Generator Sets Notes...

Page 25: ...Standby Generator Sets Notes...

Page 26: ...Standby Generator Sets Notes...

Page 27: ...Standby Generator Sets Notes...

Page 28: ......

Page 29: ...L D 0F0492 1 INSULATOR CB S ED 3P E 048927 4 SCREW RHM 10 32 X 4 1 2 F 023897 4 WASHER FLAT 10 ZINC G 022152 4 WASHER LOCK 10 H 022158 4 NUT HEX 10 32 STEEL J 0C2454 7 SCREW THF M6 1 X 16 N WA Z JS K...

Page 30: ......

Page 31: ...5 X 20 G8 T 022145 6 WASHER FLAT 5 16 M8 ZINC U 045771 3 NUT HEX M8 1 25 G8 CLEAR ZINC V 0F8843 3 BUS BAR 200A LUG ADAPTOR 1 W W CB 2 TERMINAL COVER CB 7 UL CIRCUIT BREAKER 400AF A 0F4187 1 COVER CB C...

Page 32: ......

Page 33: ...EARING CARRIER 390 DRCT 8 0F7874 1 ASSY BRUSH HOLDER 390 HSB 9 0G0587 1 GUARD REAR BEARING CARRIER 10 038150 4 WASHER FLAT 8 ZINC 11 023454 1 KEY WOODRUFF E 12 077043F 1 CONDUIT FLEX 1 1 4 30 LG 13 04...

Page 34: ......

Page 35: ...0F6305 2 SEAL COVER 3 18X12 7X382 27 0F6305A 1 SEAL COVER 3 18X12 7X283 28 0F5886 3 SCREW HHPM M5 0 8 X 12 29 051713 12 WASHER FLAT M5 30 049226 12 WASHER LOCK M5 31 0F5752F 1 RES WW 15R 5 25W QK CON...

Page 36: ......

Page 37: ...4 13 022097 1 WASHER LOCK M6 1 4 14 022473 2 WASHER FLAT M6 1 4 ZINC 15 049813 1 NUT HEX M6 1 0 G8 YEL CHR 16 022261 1 WASHER SHAKEPROOF INT 3 8 17 0F9597A 1 SUPPORT LH ENGINE 2 4L 18 045764 1 SCREW...

Page 38: ......

Page 39: ...FLAT 3 8 M10 ZINC 7 050331A REF BATTERY POST COVER RED 8 050331 REF BATTERY POST COVER BLACK 9 038805Y 1 CABLE BATTERY BLACK 1 X 18 00 10 03880400AE 1 CABLE BATT RED 1 X 18 00 11 045771 REF NUT HEX M8...

Page 40: ......

Page 41: ...TOR W PVC CONN 3 0C8127 1 ELEMENT AIR CLEANER 4 052619 4 SCREW HHC M5 0 8 X 20 G8 8 5 022127 1 NUT HEX 1 4 20 STEEL 6 062974 1 STUD TH 1 4 20 X 4 1 2 G2 ZNC 7 0G0190 1 PLATE AIR CLEANER TOP 2 4L 8 037...

Page 42: ......

Page 43: ...CHR 29 058306 15 REF SCREW SHC M8 1 25 X 25 G12 9 30 022097 3 WASHER LOCK M6 1 4 31 022473 3 WASHER FLAT 1 4 M6 ZINC 32 043116 3 SCREW HHC M6 1 0 X 12 G8 8 33 026073A 2 REF PLUG STD PIPE 1 4 STEEL SQ...

Page 44: ......

Page 45: ...11 1 SCREW HHC M10 1 5 X 30 G8 8 31 0F2872 1 SCREW HHC 1 2 13 X 2 G8 32 022304 2 WASHER FLAT 1 2 ZINC 33 022195 1 WASHER LOCK 1 2 34 022196 1 NUT HEX 1 2 13 STEEL 35 0F8651 9 SCREW HHFC M8 1 25 X 20 W...

Page 46: ......

Page 47: ...1 5 ID X 2 LG 20R4 35KW 22 0E6382B 1 VENTURI HOLDER W 40MM ACTUATOR 45KW 0E6382C 1 VENTURI HOLDER W 32MM ACTUATOR 35KW 23 0F7790E 1 VENTURI THROTTLE 26MM 24 0E7121 1 O RING 47 625 ID X 2 38 WIDTH 25 0...

Page 48: ......

Page 49: ...IM 440 64 LG 27 0F3760K 2 INSULATION SPLITTER 28 0F3760E 2 INSULATION SPLITTER 29 0F4051C 2 INSULATION DUCT 30 0F3890B 10 RETAINER INSULATION 820 31 0F4051B 2 INSULATION DUCT SIDES 32 0F3890 4 RETAINE...

Page 50: ......

Page 51: ...EXHAUST WELDMENT 11 044149 1 GASKET EXHAUST RING 12 085917 2 WASHER LOCK 3 8 SS 13 0D2611 2 SCREW HHC 3 8 16 X 1 3 4 SS 14 0E8816 1 EXHAUST FLANGE 2 PIPE 15 049721 4 SCREW HHC M6 1 0 X 35 G8 8 BLK 16...

Page 52: ......

Page 53: ......

Page 54: ......

Page 55: ......

Page 56: ......

Page 57: ......

Page 58: ......

Page 59: ......

Page 60: ......

Page 61: ......

Page 62: ......

Page 63: ...B 0C2454 3 SCREW THF M6 1 X 16 N WA Z JS 3 C4 UNITS A 0F9832A 1 SHIELD CONTROL STAND C4 B 0C2454 2 SCREW THF M6 1 X 16 N WA Z JS 4 C5 UNITS A 0F9832C 1 SHIELD CONTROL STAND C5 0F9832D 1 SHIELD CONTROL...

Page 64: ...ts Failures due but not limited to accident misuse abuse negligence or improper installation As with all mechanical devices the Carrier engines need periodic part s service and replacement to perform...

Reviews: