![Carrier AQUAZONE 50PSH Installation, Start-Up And Service Instructions Manual Download Page 38](http://html.mh-extra.com/html/carrier/aquazone-50psh/aquazone-50psh_installation-start-up-and-service-instructions-manual_2563405038.webp)
38
LEGEND
Table 8 —
Second Data Plate for Units with Electric Heater Option and Constant Airflow ECM Motor
a
,
b
,
c
NOTE(S):
a. Units with Factory Installed Electric Heat option will have two separate data plates for each electrical circuit.
b. Electric heat is not available for horizontal-straight through airflow configuration.
c. 4-wire design (L1, L2, L3, N) is required on 460V 3-Phase units with Constant Airflow ECM motor.
UNIT
SIZE
EH
RATED
kW
STAGE
HEATER WATTS
HEATER AMPS
MOTOR
FLA
(A)
CIRCUIT
MCA
MOP
240
208
240
208
FUSES
240
208
240
208
018
4.8
1
4,800
3,600
20.0
17.3
2.8
—
28.5
25.1
30
30
024
4.8
1
4,800
3,600
20.0
17.3
2.8
—
28.5
25.1
30
30
9.6
1
9,600
7,200
40.0
34.6
2.8
—
53.5
46.8
60
50
030
4.8
1
4,800
3,600
20.0
17.3
2.8
—
28.5
25.1
30
30
9.6
1
9,600
7,200
40.0
34.6
2.8
—
53.5
46.8
60
50
036
4.8
1
4,800
3,600
20.0
17.3
4.3
—
30.4
27.0
35
30
9.6
1
9,600
7,200
40.0
34.6
4.3
—
55.4
48.6
60
50
14.4
2
14,000
10,800
60.0
51.9
4.3
F1/F2
80.4
70.3
90
80
F3/F4
042
4.8
1
4,800
3,600
20.0
17.3
6.8
—
33.5
30.1
35
35
9.6
1
9,600
7,200
40.0
34.6
6.8
—
58.5
51.8
60
60
14.4
2
14,400
10,800
60.0
51.9
6.8
F1/F2
83.5
73.4
90
80
F3/F4
048
4.8
1
4,800
3,600
20.0
17.3
6.8
—
33.5
30.1
35
35
9.6
1
9,600
7,200
40.0
34.6
6.8
—
58.5
51.8
60
60
14.4
2
14,400
10,800
60.0
51.9
6.8
F1/F2
83.5
73.4
90
80
F3/F4
19.2
2
19,200
14,000
80.0
69.2
6.8
F1/F2
108.5
95.0
110
100
F3/F4
060
4.8
1
4,800
3,600
20.0
17.3
6.8
—
33.5
30.1
35
35
9.6
1
9,600
7,200
40.0
34.6
6.8
—
58.5
51.8
60
60
14.4
2
14,400
10,800
60.0
51.9
6.8
F1/F2
83.5
73.4
90
80
F3/F4
19.2
2
19,200
14,000
80.0
69.2
6.8
F1/F2
108.5
95.0
110
100
F3/F4
070
4.8
1
4,800
3,600
20.0
17.3
9.1
—
36.4
33.0
35
35
9.6
1
9,600
7,200
40.0
34.6
9.1
—
61.4
54.6
70
60
14.4
2
14,400
10,800
60.0
51.9
9.1
F1/F2
86.4
76.3
90
80
F3/F4
19.2
2
19,200
14,000
80.0
69.2
9.1
F1/F2
111.4
97.9
120
100
F3/F4
EH
—
Electric Heat
FLA
—
Full Load Amps
MCA
—
Minimum Circuit Amps
MOP
—
Maximum Overcurrent Protection
Summary of Contents for AQUAZONE 50PSH
Page 17: ...17 Fig 15 PSC Motor Single Phase Single Stage WSHP Open Control ...
Page 20: ...20 Fig 18 Constant Torque Motor Single Phase Single Stage WSHP Open Control ...
Page 23: ...23 Fig 21 Constant Airflow Single Phase WSHP Open ...
Page 26: ...26 Fig 24 PSC Motor Three Phase Single Stage WSHP Open ...
Page 29: ...29 Fig 27 Constant Torque Motor Three Phase Single Stage WSHP Open ...
Page 32: ...32 Fig 30 Constant Airflow Motor Three Phase Single Stage WSHP Open ...