GB - 5

E N G L I S H

B

A

PREPARATION

Cooling with dehumidification

A

       B

Cooling with dehumidification

CONTROL
PANEL

INFRARED
REMOTE CONTROL

Cooling with

dehumidif.

1

2

3

6

7

10

15

11

12

IMPORTANT
When the room air temperature is above 30

°

C, the  fan motor is switched automatically to run at high speed.

2
3

8

B       F         E

Insert the air outlet vent into end 

B

 of the

flexible pipe.

Move the air
conditioner close
to the window,
stretching the hose
as little as possible
(max. extension
1100 mm).
Place the air outlet
vent of the flexible
hose outside the
window.

The flexible pipe supplied with the unit is
positioned at the rear of the unit.
Insert end 

A

 into the connection

provided.

WATER PUMP

DRAINAGE:

Connect the water pump drain

hose to the unit before

operation.

When the water in the internal

tank will reach a

predetermined level, the

water pump will be activated

and the condensate will be

drained out thought the

connected drain hose.

DO NOT FORGET TO

CONNECT DRAIN HOSE.

CONTINUOUS

DRAINAGE:

When you plan to leave the unit

unused for a long time or you

need continuous drainage,

remove the rubber blockage from

the lower back hole and attach a

tube of the right dimension to

drain hose connector. All the

condensate in the water tank

would be drained

outside through the lower drain

hose during operation. Under

this condition the water pump is

not activated.

• Switch on the unit by pressing button 

1

 

.

• Using the function selector (button 

2

), select the COOLING mode. For

confirmation, the cooling LED 

15

 

 will light up on the control panel.

• By pressing the temperature selector (button 

6

), select the desired temperature

which will appear on the display 

7

.

• Using the fan speed selector (button 

3

), select the fan speed desired (low,

medium or high).  For confirmation, the LED 

10

 or 

11

 or 

12

  will light up on the

control panel according with the fan speed selected.

• Switch on the unit by pressing button 

8

.

• Using the operating mode function selector

(button 

2

), select the COOLING mode. For

confirmation, the arrow of operating mode
display (B) will indicate the mode chosen.

  •By pressing the temperature selectors (buttons

1

 and 

9

 ), select the desired temperature which

will appear on the display area (F).

• Using the fan speed selector (button 

3

), select

the fan speed desired (low, medium or high).
For confirmation, the arrow of fan speed
display (E) will indicate the fan speed chosen.

Summary of Contents for Allegro 51AKE075

Page 1: ...51AKE L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 OWNER S MANUAL ...

Page 2: ...ction manual thoroughly before using the air conditioner Description of the unit External appearance of the unit Accessories 1 2 3 4 5 Warning Don t forget to connect the water pump drain hose before starting the air conditioner see details on pages 5 햲 햳 햴 햵 햶 햷 햸 햹 햺 햻 햽 햾 FRONT VIEW SIDE VIEW REAR VIEW 1 Flexible hose 2 Air outlet vent 3 Water pump drain hose 4 Fastening strap with suction 5 Re...

Page 3: ...ed while compliance with local regulation must be ensured For additional information please contact the municipal facility the shop dealer installer that have sold the product or the producer Remote control Do not use used batteries of different types as this may cause the unit to malfunction The average battery life during normal use is approximately 6 months No obstructions such as curtains or p...

Page 4: ...on 2 Operating mode selector 3 Fan speed selection button 4 Reset button 5 Lock button 6 Timer operation OFF 7 Timer operation ON 8 ON OFF button 9 Increase temperature button Display panel A Transmission indicator B Operating mode display auto cool dry C Lock display D Timer display E Fan speed display High Med Low F Digital display area temperature selected and timer informations when used How t...

Page 5: ... sides front and rear grille with curtains or other objects Do not put objects on the unit The distance between the return air grills and any walls furniture or obstructions of all kinds must be at least 300 mm If the air conditioner is switched off and immediately switched on again there will be a 3 minute delay before the compressor starts up to ensure the correct operation of the unit see Prote...

Page 6: ...age remove the rubber blockage from the lower back hole and attach a tube of the right dimension to drain hose connector All the condensate in the water tank would be drained outside through the lower drain hose during operation Under this condition the water pump is not activated Switch on the unit by pressing button 1 Using the function selector button 2 select the COOLING mode For confirmation ...

Page 7: ...DRAINAGE See page 5 CONTINUOUS DRAINAGE See page 5 Switch on the unit by pressing button 1 Using the function selector button 2 select the DEHUMIDIFICATION mode For confirmation the dehumidification LED 14 will light up on the control panel IMPORTANT The temperature displayed on control panel is the room air temperature Switch on the unit by pressing button 8 Using the operating function selector ...

Page 8: ...light up on the control panel according with the fan speed selected IMPORTANT The temperature displayed on control panel is the room air temperature Advise Keep windows and doors closed Maintain the exhaust air duct inside the room with the shortest duct length Switch on the unit by pressing button 8 Using the operating mode selector button 2 select the FAN ONLY mode For confirmation the arrow of ...

Page 9: ...he timer is programmed the LED 9 will light up on the control panel Example The present time is 09 00 a m and you want the air conditioner from ON mode switches off after 1 1 2 hours Press and depress the 4 button until the figure 1 5 appears on the display Now the air conditioner is programmed to switch off at 10 30 a m and for confirmation the LED 9 will remain lighted up IMPORTANT The timer pro...

Page 10: ...D Example The present time is 09 00 a m and you want the air conditioner from ON mode switches off after 1 1 2 hours Press and depress the 6 button until the figure 1 5 appears on the display area F Now the air conditioner is programmed to switch off at 10 30 a m and for confirmation TIMER OFF will appear on the display D IMPORTANT The timer program can be changed at any time To delete the timer p...

Page 11: ...n warm water about 40 with a neutral detergent Rinse the filter and let it dry in a shady place Mounting Attach the air filter to its cover using the fixing hooks on the inner surface of the cover Put the filter cover back on the unit Special remote control function AUTO MODE This function is available exclusively by infrared remote control Using the operating mode selector button 2 select AUTO Fo...

Page 12: ...mum compressor run time is at least 3 minutes As soon as the temperature detected by evaporator coil sensor is at least 10 C the compressor will be ready to restart Compressor short cycling protection This protection has the purpose to prevent too short compressor start up When the compressor cycles from On to Off it will remain Off for a minimum of 3 minutes before being ready to restart Water ta...

Page 13: ...igerant inside the air conditioner WHAT TO DO Make sure the main switch is on Make sure the plug is correctly inserted in the socket Drain all the water from the drain tank Set the desired temperature correctly Make sure all the windows and doors are closed Make sure all the windows and doors are closedRemove all heating sources if possible Connect the duct and make sure it can function properly D...

Page 14: ...51AKE OM Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice July 2005 Printed in China ...

Reviews: