GB - 11

E N G L I S H

Diagnostic & Protections

Fault code:
• P1 on the control panel is flashing

Cause:

• Water level in the drain tank is up to the limit

Remedy:
• Empty the water  tank through the hole of continuous

drainage.

Important note:
In this event, the LED 16 blinks  twice per second and the
unit is switched to FAN mode automatically.

In the event of a malfunction or failures , a warning message fault code and a LED (13 or 15) will be flashed on the unit display as follow:

Fault code:
• E2 on the control panel is flashing together the LED 13.

Cause:
• Room air sensor fault

Remedy:
• Replace it by authorized Service technician.

Important note:
In this event, the unit is stopped.

To guarantee that this appliance can be
safe and reliable, the unit control can
activate the following protections either
cooling or dehumidification mode:

Heat Exchanger freeze protection

This protection has the purpose to prevent
the evaporator coil from freezing.

This control will stop the compressor when
both of the underneath condition are true:
• the temperature detected by evaporator

coil sensor is less than 2 

°

C,

• the minimum compressor run time is at

least 3 minutes.

As soon as the temperature detected by
evaporator coil sensor is at least 10 

°

C,

the compressor will be ready to restart.

Compressor short cycling protection

This protection has the purpose to prevent
too short compressor start up.

When the compressor cycles from On to
Off, it will remain Off for a minimum of 3
minutes before being ready to restart.

Water tank safety feature

This unit is equipped with an internal water
tank and a double-step switch mechanism:

• the first step is used to control drainage

by the water pump.

• the second step is used to monitor the

maximum water level inside the internal
water tank.

Fault code:
•  E1 on the control panel is flashing together the LED 15.

Cause:
• Evaporator coil sensor fault

Remedy:
• Replace it by authorized Service technician.

Important note:
In this event, the unit is stopped.

When the water level reaches the second
step:
• the digital display will show “P1”,
• the water full indicator light  will start

flashing twice per second,

• the air conditioner will enter the “FAN”

mode automatically.

In case this event happens:
• Unplug the unit and carefully move it in a

safe area, as a bathroom or laundry.

• Remove the rubber blockage from the

lower back drainage hole and drain the
water away using a tube of the right
dimension.

Summary of Contents for Allegro 51AKE075

Page 1: ...51AKE L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1 OWNER S MANUAL ...

Page 2: ...ction manual thoroughly before using the air conditioner Description of the unit External appearance of the unit Accessories 1 2 3 4 5 Warning Don t forget to connect the water pump drain hose before starting the air conditioner see details on pages 5 햲 햳 햴 햵 햶 햷 햸 햹 햺 햻 햽 햾 FRONT VIEW SIDE VIEW REAR VIEW 1 Flexible hose 2 Air outlet vent 3 Water pump drain hose 4 Fastening strap with suction 5 Re...

Page 3: ...ed while compliance with local regulation must be ensured For additional information please contact the municipal facility the shop dealer installer that have sold the product or the producer Remote control Do not use used batteries of different types as this may cause the unit to malfunction The average battery life during normal use is approximately 6 months No obstructions such as curtains or p...

Page 4: ...on 2 Operating mode selector 3 Fan speed selection button 4 Reset button 5 Lock button 6 Timer operation OFF 7 Timer operation ON 8 ON OFF button 9 Increase temperature button Display panel A Transmission indicator B Operating mode display auto cool dry C Lock display D Timer display E Fan speed display High Med Low F Digital display area temperature selected and timer informations when used How t...

Page 5: ... sides front and rear grille with curtains or other objects Do not put objects on the unit The distance between the return air grills and any walls furniture or obstructions of all kinds must be at least 300 mm If the air conditioner is switched off and immediately switched on again there will be a 3 minute delay before the compressor starts up to ensure the correct operation of the unit see Prote...

Page 6: ...age remove the rubber blockage from the lower back hole and attach a tube of the right dimension to drain hose connector All the condensate in the water tank would be drained outside through the lower drain hose during operation Under this condition the water pump is not activated Switch on the unit by pressing button 1 Using the function selector button 2 select the COOLING mode For confirmation ...

Page 7: ...DRAINAGE See page 5 CONTINUOUS DRAINAGE See page 5 Switch on the unit by pressing button 1 Using the function selector button 2 select the DEHUMIDIFICATION mode For confirmation the dehumidification LED 14 will light up on the control panel IMPORTANT The temperature displayed on control panel is the room air temperature Switch on the unit by pressing button 8 Using the operating function selector ...

Page 8: ...light up on the control panel according with the fan speed selected IMPORTANT The temperature displayed on control panel is the room air temperature Advise Keep windows and doors closed Maintain the exhaust air duct inside the room with the shortest duct length Switch on the unit by pressing button 8 Using the operating mode selector button 2 select the FAN ONLY mode For confirmation the arrow of ...

Page 9: ...he timer is programmed the LED 9 will light up on the control panel Example The present time is 09 00 a m and you want the air conditioner from ON mode switches off after 1 1 2 hours Press and depress the 4 button until the figure 1 5 appears on the display Now the air conditioner is programmed to switch off at 10 30 a m and for confirmation the LED 9 will remain lighted up IMPORTANT The timer pro...

Page 10: ...D Example The present time is 09 00 a m and you want the air conditioner from ON mode switches off after 1 1 2 hours Press and depress the 6 button until the figure 1 5 appears on the display area F Now the air conditioner is programmed to switch off at 10 30 a m and for confirmation TIMER OFF will appear on the display D IMPORTANT The timer program can be changed at any time To delete the timer p...

Page 11: ...n warm water about 40 with a neutral detergent Rinse the filter and let it dry in a shady place Mounting Attach the air filter to its cover using the fixing hooks on the inner surface of the cover Put the filter cover back on the unit Special remote control function AUTO MODE This function is available exclusively by infrared remote control Using the operating mode selector button 2 select AUTO Fo...

Page 12: ...mum compressor run time is at least 3 minutes As soon as the temperature detected by evaporator coil sensor is at least 10 C the compressor will be ready to restart Compressor short cycling protection This protection has the purpose to prevent too short compressor start up When the compressor cycles from On to Off it will remain Off for a minimum of 3 minutes before being ready to restart Water ta...

Page 13: ...igerant inside the air conditioner WHAT TO DO Make sure the main switch is on Make sure the plug is correctly inserted in the socket Drain all the water from the drain tank Set the desired temperature correctly Make sure all the windows and doors are closed Make sure all the windows and doors are closedRemove all heating sources if possible Connect the duct and make sure it can function properly D...

Page 14: ...51AKE OM Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice July 2005 Printed in China ...

Reviews: