6
−
16
T-364
6.21.3 Programming Procedure for Software Ver-
sions 5354 and Greater & With Updated
Menu Option (menu0115.ml)
NOTE
Units must be loaded with software version
5354 or higher. See the label in the control box
door for factory installed software version.
The updated menu option allows the operational soft-
ware to be loaded, and time and container identification
to be set.
a. Procedure for loading operational software:
1. The display module will display the message Set UP.
2. Press the UP or DOWN arrow key until the display
reads, LOAd 53XX for Scroll.
3. Press the ENTER key on the keypad.
4. The display will alternate to between PrESS EntR
and rEV XXXX.
5. Press the ENTER key on the keypad.
6. The display will show the message “Pro SoFt”. This
message will last for up to one minute.
7. The display module will go blank briefly, then read
“Pro donE” when the software loading has loaded. (If
a problem occurs while loading the software: the dis-
play will blink the message “Pro FAIL” or “bad 12V.”
Turn start-stop switch OFF and remove the card.)
8. Turn unit OFF, via start-stop switch (ST).
9. Remove the PCMCIA card from the programming/
software port and return the unit to normal operation
by placing the start-stop switch in the ON position.
10.Turn power on and wait about 15 seconds for the
new software to load into the controller memory. The
status LED will flash quickly and the display will re-
main blank as the controller loads the new software.
When complete, the controller will reset and power
up normally.
11. Wait for default display, setpoint on the left, and con-
trol temperature on the right.
12.Confirm software is correct using keypad code se-
lect 18 to view Cd18 XXXX.
13.Turn power off. Operational software is loaded.
b. Procedure for loading configuration software:
1. Turn unit OFF using start-stop switch (ST).
2. Insert software/programming PCMCIA card contain-
ing the following (example) files into the program-
ming/software port. (See Figure 6
menuDDMM.ml3, this file allows the user to select
the file/program to upload into the controller.
cfYYMMDD.ml3
, multi-configuration file.
3. Turn unit ON using start-stop switch (ST).
4. Press the UP or DOWN arrow key until display reads
Set UP.
5. Press the ENTER key on the keypad.
6. Press the UP or DOWN arrow key until display reads
XXXX the message ruN COnFG. (If a defective card
is being used the display will blink the message “bAd
CArd.” Turn start-stop switch OFF and remove the
card.)
7. Press the ENTER key on the keypad.
8. The display module will go blank briefly and then dis-
play “551 00”, based on the operational software
installed.
9. Press the UP or DOWN ARROW key to scroll
through the list to obtain the proper model dash num-
ber. (If a defective card is being used, the display will
blink the message “bAd CArd.” Turn start-stop
switch OFF and remove the card.)
10.Press the ENTER key on the keypad.
11. When software loading has successfully completed,
the display will show the message “EEPrM donE.” (If
a problem occurs while loading the software, the dis-
play will blink the message “Pro FAIL” or “bad 12V.”
Turn start-stop switch OFF and remove the card.)
12.Turn unit OFF using start-stop switch (ST).
13.Remove the PCMCIA card from the programming/
software port and return the unit to normal operation
by placing the start-stop switch in the ON position.
14.Confirm correct model configuration using the key-
pad to choose code 20 (CD20). The model displayed
should match the unit serial number plate.
c. Procedure for setting the date and time:
NOTE
If you are performing this procedure by itself,
5 of b. Procedure
for loading configuration software
.
1. Press the UP or DOWN arrow key until display reads
Set TIM.
2. Press the ENTER key on the keypad.
3. The first value to be modified is the date in YYYY
MM
−
DD format. The values will be entered from right
to left. Press the UP or DOWN ARROW key to in-
crease or decrease the values. The ENTER key will
enter the information for the current field and move to
the next value; the CODE SELECT key will allow
modification of the previous value.
4. Press the ENTER key on the keypad.
5. The next value to be modified is the time in HH MM
format. The values will be entered from right to left.
Press the UP or DOWN ARROW key to increase or
decrease the values. The ENTER key will enter the
information for the current field and move to the next
value; the CODE SELECT key will allow modification
of the previous value.
6. Press the ENTER key on the keypad. The date and
time will not be committed until start up procedures
are completed on the next power up.
d. Procedure for setting the container ID:
NOTE
If you are performing this procedure by itself,
5 of b. Procedure
for loading configuration software
.
1. Press the UP or DOWN arrow key until display reads
Set ID.
2. Press the ENTER key on the keypad.
Summary of Contents for 69NT40-561-201
Page 2: ......
Page 11: ......
Page 15: ......
Page 29: ......
Page 81: ......
Page 108: ...7 2 T 364 Based on Drawing 62 11753 Figure 7 2 SCHEMATIC DIAGRAM ...
Page 109: ...7 3 T 364 Based on Drawing 62 11753 Figure 7 3 UNIT WIRING DIAGRAM Sheet 1 of 2 ...
Page 110: ...7 4 T 364 Based on Drawing 62 11753 Figure 7 3 UNIT WIRING DIAGRAM Sheet 2 of 2 ...
Page 111: ......
Page 115: ......
Page 116: ......