![Carrier 69NT40-551-500 Operation And Service Download Page 95](http://html1.mh-extra.com/html/carrier/69nt40-551-500/69nt40-551-500_operation-and-service_2563844095.webp)
6--24
T-334
a. Turn power to the unit OFF.
b. Open the recorder door (item 1, see Figure 6--24).
c. Locate the connector below the recorder, and
squeeze the ears together to disconnect the plug,
(item 10 ).
d. Remove the four mounting screws (item 2), and
remove the recorder.
e. Install the new recorder by reversing the above
steps.
6.23.2 Changing the Chart
NOTE
To prevent recorder corrosion, it is important to
assure the door is securely closed at all times
after completing the chart change.
a. Lift the stylus (item 5, Figure 6--24) by grasping the
arm near the base, and pull the arm away from the
chart until it snaps into its retracted position.
b. Remove the chart retaining nut (item 10), remove
the used chart, and record today’s date on the old
chart.
c. Press the “Change Chart” button (item 2).
NOTE
Failure to press the change chart button, when
changing a chart with the power OFF, may
result in the chart advancing when power is
applied.
d. Install a new chart, make sure the chart center hole
is placed over the center hub, and the chart edges
are behind the four hold down tabs (item 9).
e. Mark today’s date, container number, and other
required information on the new chart and install
under hold down tabs.
f.
Replace the chart nut loosely, rotate the chart until
the correct day is aligned with the “start arrow,” and
hand tighten the chart nut.
g. Gently lower the stylus arm until the pen tip (item 4)
comes in contact with the chart.
CAUTION
Do not allow the recorder stylus to snap
back down. The stylus arm base is spring
loaded, and damage may occur to the chart,
or the stylus force may be altered.
DO NOT move the stylus arm up and down
on the chart face. This will result in damage
to the stylus motor gear.