3--29
T-334
Table 3--9 DataCORDER Pre-Trip Result Records
Test
No.
TITLE
DATA
1-0
Heater On
Pass/Fail/Skip Result, Change in current for Phase A, B and C
1-1
Heater Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
2-0
Condenser Fan On
Pass/Fail/Skip Result, Water pressure switch (WPS) - Open/Closed,
Change in currents for Phase A, B and C
2-1
Condenser Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-0
Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-1
Low Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-0
High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-1
High Speed Evaporator Fan
On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
5-0
Supply/Return Probe Test
Pass/Fail/Skip Result, STS, RTS, SRS and RRS
5-1
Secondary Supply Probe Test Pass/Fail/Skip
5-2
Secondary Return Probe Test
Pass/Fail/Skip
6-0
Discharge Thermistor Test
Pass/Fail/Skip
6-1
Suction Thermistor Test
Pass/Fail/Skip
6-2
Discharge Pressure Sensor
Test
Pass/Fail/Skip
6-3
Suction Pressure Sensor Test Pass/Fail/Skip
6-4
Compressor Current Draw
Test
Pass/Fail/Skip
6-5
Suction Modulation valve Test Pass/Fail/Skip
6-6
Economizer Valve Test
Pass/Fail/Skip
6-7
Unloader Valve Test
Pass/Fail/Skip
7-0
High Pressure Switch Closed
Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens
7-1
High Pressure Switch Open
Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
8-0
Perishable Mode Heat Test
Pass/Fail/Skip Result, STS, time it takes to heat to 16C (60F)
8-1
Perishable Mode Pulldown
Test
Pass/Fail/Skip Result, STS, time it takes to pull down to 0C (32F)
8-2
Perishable Mode Maintain
Test
Pass/Fail/Skip Result, Averaged DataCORDER supply temperature
(SRS) over last recording interval.
9-0
Defrost Test
Pass/Fail/Skip Result, DTS reading at end of test, line voltage, line
frequency, time in defrost.
10-0
Frozen Mode Heat Test
Pass/Fail/Skip Result, STS, time unit is in heat.
10-1
Frozen Mode Pulldown Test
Pass/Fail/Skip Result, STS, time to pull down unit to -17.8C (0F).
10-2
Frozen Mode Maintain Test
Pass/Fail/Skip Result, Averaged DataCORDER return temperature
(RRS) over last recording interval.