2–9
T-319
2.2
REMOTE EVAPORATOR
The dual temperature system includes a remote evaporator assembly. This assembly consists of three major com-
ponents: the frame, the guard, and several clamp assemblies that accommodate the additional lines.
Refrigerant piping and wiring harness are mounted within the ceiling box recess to guard against damage to the
components.
2.2.1
Frame
The remote evaporator frame accommodates the refrigeration components, electrical kit, wire harness, and heater
kit (see
Figure 2.10 Remote Evaporator - Frame (69NT40-541-304)
1. Evaporator Skin Assembly
2. Evaporator Access Panel
3. Evaporator Top Frame
4. Evaporator Drain Pan
5. Blower Motor Venturi Ring
- - - - -
Side View
Summary of Contents for 69NT40-541-304
Page 2: ......
Page 4: ......
Page 8: ...T 319 iv...
Page 14: ...T 319 1 4...
Page 34: ...T 319 2 20...
Page 48: ...T 319 5 2...
Page 61: ...7 3 T 319 Figure 7 2 Schematic 69NT40 541 304...
Page 62: ...T 319 7 4 Figure 7 3 Unit Wiring Diagram Sheet 1 69NT40 541 304...
Page 63: ...7 5 T 319 Figure 7 4 Unit Wiring Diagram Sheet 2 69NT40 541 304...
Page 64: ...T 319 7 6 Figure 7 5 Legend 69NT40 541 345...
Page 65: ...7 7 T 319 Figure 7 6 Schematic 69NT40 541 345...
Page 66: ...T 319 7 8 Figure 7 7 Unit Wiring Diagram Sheet 1 69NT40 541 345...
Page 67: ...7 9 T 319 Figure 7 8 Unit Wiring Diagram Sheet 2 69NT40 541 345...
Page 68: ...T 319 7 10...
Page 77: ...12 4 T 319...
Page 78: ...T 319 13 1 13 RECEIVER 8 5 17 18 19 20 4 Item 1 4 2 3 6 7 8 6 7 10 9 11 12 13 14 15 16 2...
Page 81: ...14 2 T 319...
Page 84: ...T 319 17 1 17 REMOTE EVAPORATOR FRAME A A A A 4 2 5 6 3 8 9 1 15 11 7 12 10 14 13 2 2 2 9 3 9...
Page 87: ...18 2 T 319...
Page 100: ...T 319 26 2...
Page 104: ...T 319 Index 4...
Page 105: ......