7
PHYSICAL DATA
UNIT SIZE
090
110
135
155
20
12
16
22
16
22
20
OUTPUT CAPACITY BTUH*
(Nonweatherized ICS) †
58STX Upflow; all 58STA
71,000
89,000
89,000
89,000
107,000
107,000
125,000
58STX Downflow/Horizontal
68,000
85,000
85,000
85,000
102,000
102,000
119,000
INPUT BTUH*
58STX Upflow; all 58STA
88,000
110,000
110,000
110,000
132,000
132,000
154,000
58STX Downflow/Horizontal
84,000
105,000
105,000
105,000
126,000
126,000
147,000
AFUE%*
Nonweatherized ICS
80.0
80.0
80.0
80.0
80.0
80.0
80.0
SHIPPING WEIGHT --- LB. (KG)
146 (66)
135 (61)
146 (66)
152 (69)
149 (68)
163 (74)
170 (77)
CERTIFIED TEMP RISE RANGE --- ° F (° C)
25---55
(14---30)
50---80
(28---44)
40---70
(22---39)
30---60
(17---33)
50---80
(28---44)
40---70
(22---39)
45---75
(25---41)
CERTIFIED EXT
STATIC PRESSURE
Heating
0.15
0.20
0.20
0.20
0.20
0.20
0.20
Cooling
0.50
0.50
0.50
0.50
0.50
0.50
0.50
AIRFLOW CFM‡
Heating
1990
1335
1515
1900
1525
1850
1790
Cooling
2025
1355
1680
2220
1710
2110
2230
LIMIT CONTROL
SPST
HEATING BLOWER CONTROL
Solid-State Time Operation
BURNERS (Monoport)
4
5
5
5
6
6
7
GAS CONNECTION SIZE
1/2---in. NPT
GAS VALVE (Redundant) Manufacturer
White-Rodgers
Minimum Inlet Pressure (In. wc)
4.5 (Natural Gas)
Maximum Inlet Pressure (In. wc)
13.6 (Natural Gas)
IGNITION DEVICE
Hot Surface
* Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft.
(305 M) above sea level. In Canada, derate the unit 10 percent for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level. Refer to National Fuel Gas
Code NFPA 54/ANSI Z223.1---2006 Table F.1 (d) or furnace Installation Instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return-air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each
return-air supply. An airflow reduction of up to 7 percent may occur when using a Carrier 4-5/16 in. (110 mm) high efficiency media filter.
ICS — Isolated Combustion System
BLOWER PERFORMANCE DATA
UNIT SIZE
090
110
135
155
20
12
16
22
16
22
20
DIRECT---DRIVE MOTOR Hp (PSC)
3/4
1/3
1/2
3/4
1/2
3/4
3/4
MOTOR FULL LOAD AMPS
11.1
5.2
7.9
11.1
7.9
11.1
11.1
RPM (Nominal)---Speeds
1075---3
1075---3
1075---3
1075---3
1075---3
1075---3
1075---3
BLOWER WHEEL DIAMETER X WIDTHS --- IN. (mm)
11 x 11
(279 x 279)
10 x 8
(254 x 203)
10 x 10
(254 x 254)
11 x 11
(279 x 279)
10 x 10
(254 x 254)
11 x 11
(279 x 279)
11 x 11
(279 x 279)
PSC---Permanent Split Capacitor
58ST
A
/S
TX
Summary of Contents for 58STX
Page 15: ...15 58STA STX ...