2
FURNACE SPECIFICATIONS
Model Number
58HDV040
58HDV060
58HDV080
58HDV100
{
INPUT
HIGH HEAT(BTUH)
LOW HEAT (BTUH)
40,000
28,000
60,000
42,000
80,000
56,000
100,000
70,000
{
HTG. CAPACITY HIGH HEAT(BTUH)
LOW HEAT (BTUH)
38,000
27,000
58,000
41,000
77,000
54,000
96,000
67,000
TEMP. RISE RANGE
HIGH HEAT (
o
F/
o
C)
LOW HEAT(
o
F/
o
C)
25--55/14--31
25--55/14--31
30--60/17--33
30--60/17--33
30--60/17--33
30--60/17--33
30--60/17--33
30--60/17--33
VENT SIZE^ in(mm)
2
″
(51) OD
2
″
-- 3
″
(51 -- 76) OD
3
″
(76) OD
3
″
(76) OD
VOLTS/HZ/PH
115/60/1
115/60/1
115/60/1
115/60/1
RATING PLATE AMPS.
9.5
11.4
14.6
14.6
MIN./MAX. VOLTAGE
104/127
104/127
104/127
104/127
TRANSFORMER (V.A.)
40
40
40
40
GAS PIPE SIZE -- inches(mm)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
COOLING CAP. (TONS)
3.0
3.5
5.0
5.0
HIGH ALTITUDE PRESSURE SWITCH
1177766
1177767
1177768
1177769
FILTER SIZE -- inches(mm) (qty)
16X25X1
(406x635x25) (1)
16X25X1
(406x635x25) (1)
16X25X1
(406x635x25) (2)
16X25X1
(406x635x25) (2)
DIMENSIONS -- WxDxH inches(mm)
19
1
/
8
x29x40
(486x737x1016)
19
1
/
8
x29x40
(486x737x1016)
22
3
/
4
x29x40
(486x737x1016)
24
1
/
2
x29x40
(622x737x1016)
WEIGHT -- Lbs(kg)
150 (68)
168 (76)
187 (85)
203 (92)
^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions.
{
Gas input ratings are certified for elevations to 2000 ft. (610 M).
In USA for elevations above 2000 ft. (610 M), ratings must be derated 2% (natural gas) or 4% (propane gas) for each 1000 ft. (305 M) above sea level.
In Canada for altitudes of 2000 ft. (610 M) to 4500 ft. (1372 M) ratings must be derated 5% (natural gas) and 10% (propane gas).
AIR INTAKE
VENT
H
G
E
F
TOP
AIR INTAKE (KO)
(ALTERNATE)
LEFT SIDE
VENT
7
2
1
/
4
6
11
/
16
1
1
/
4
ELECTRICAL
4
13
/
16
1
1
/
16
1
11
/
16
17
5
/
16
24
1
/
16
19
13
/
16
28
3
/
4
29
7
/
8
TRAP (KO)
UPFLOW/HORIZONTAL
1
7
/
8
21
5
/
8
24
13
1
/
4
4
7
/
8
TRAP (KO) (COUNTERFLOW)
13
11
/
16
31
11
/
16
1
3
/
8
THERMOSTAT
GAS
A
FRONT
B
D
23
1
/
8
C
BOTTOM
3
7
/
8
AIR INTAKE (KO)
(ALTERNATE)
RIGHT SIDE
VENT (KO)
7
1
1
/
4
ELECTRICAL (KO)
28
1
/
2
TRAP (KO)
UPFLOW/HORIZONTAL
TRAP (KO)
(COUNTERFLOW)
1
3
/
16
THERMOSTAT
GAS (KO)
18
1
/
2
3
/
4
TYPE
2
7
/
8
4
5
/
16
40
2
3
/
8
1
1
/
16
4
13
/
16
1
1
/
16
1
11
/
16
17
5
/
16
21
5
/
8
2
1
/
4
13
1
/
4
24
4
7
/
8
21
5
/
8
1
7
/
8
29
7
/
8
27
3
/
16
9
13
/
16
33
11
/
16
NOTE: Evaporator “A” coil drain pan dimensions may
vary from furnace duct opening size. Always consult
evaporator specifications for duct size requirements.
Furnace is designed for bottom return or side return.
Return air through back of furnace is NOT allowed.
(KO)
(KO)
KO = KnockOut
ALL DIMENSIONS: in (mm)
(34.9)
(503.2)
(347.7)
(804.9)
(758.8)
(730.3)
(611.2)
(439.7)
(42.9)
(123.8)
(609.6)
(549.3)
(47.6 )
(336.6)
(57.2)
(122.2)
(27)
(318)
(177.5)
(609.6)
(30.2)
(249.2)
(177.8)
(31.7)
(73)
(549.3)
(27)
(109.5)
(122.2)
(758.8)
(690.6)
(549.3)
(855.7)
(439.7)
(42.9)
(123.8)
(177.8)
(47.6)
(469.9)
(723.9)
(57.2)
(336.6)
(60.3 )
(27)
(1016)
(19.1)
(587.4)
(98.4)
Cabinet to Combustible Clearances -- in(mm)
TOP
BOT
RH
LH
BACK
FRNT
FLUE
1 (25.4)
0
0
0
0
3(76.2)
0
MINIMUM CLEARANCES TO COMBUSTIBLE
MATERIALS FOR ALL UNITS -- in (mm)
REAR
0
FRONT (combustion air openings in
furnace and in structure)
3“ (76.2)
Required For Service
*
24” (609.6)
ALL SIDES Of SUPPLY PLENUM
1” (25.4)
SIDES
0
VENT
0
TOP OF FURNACE
1” (25.4)
*30 “ (762mm) clearance recommended for furnace removal.
Horizontal position: Line contact is permissible only between lines
formed by intersections of top and two sides of furnace jacket, and
building joists, studs or framing.
A09241
58H
D
V