Low ambient lockout

 locks out com-

pressor at ambient temperatures below 
40 F to extend compressor life.

Random restart

 is used when power 

is turned on after a power outage. A 
built-in random restart (3 to 4 minutes) 
prevents all the compressors from re-
starting simultaneously.

Compressor restart delay

 of 3 min-

utes ensures that system pressures are 
allowed to equalize before a compres-
sor restart, which extends compressor 
life.

Front desk control

 allows the user, 

when the unit is wired to a front desk 
console, to enable or disable each unit 
from the front desk, thus saving the en-
ergy used to condition unoccupied 
rooms.

Fan delay

 allows the evaporator blow-

er to continue running for up to        
45 seconds after the thermostat is sat-
isfied. This feature maximizes cooling 
performance.

Ease of service

A service pullout is factory installed for 
service convenience and maintenance.
  Filter brackets and throwaway filter 
are shipped with each unit and are field 
installed over the unit’s evaporator 
coil. Filter size is 18 x 24 x 1-inch.

Adjustable operation

An adjustable fresh air (manual) damp-
er can be used to meet code require-
ments for fresh air introduction. When 
opened, the fresh air vent allows up to 
50 cfm of outside air to be introduced 
into the equipment closet. The air then 
mixes with return air entering the clos-
et through the return-air grille. See Ap-
plication Data section for more          
information.

Thermostat control

The 52V unit is easily controlled by a 
standard low voltage wall-mounted 
thermostat instead of complicated unit-
mounted controls. Low voltage wires 
are routed out the left side of the     
cabinet.

Easy installation

Rear or side installation wall sleeves 
are provided for pre-installation. When 
ready, the 52V unit is simply slid into 

the sleeve and the ductwork and elec-
trical are connected.
  The sleeve is weight-bearing and sup-
ports the entire weight of the 52V unit. 
The sleeve provides a weather tight 
seal against wind and water infiltration. 

3

/

4

-in. male NPT fitting is provided 

in the bottom of the sleeve for field 
connection to a condensate riser.
  Four wall sleeve depths are available 
to accommodate wall thickness from 5 
to 20 inches. Each sleeve includes a 
factory-installed weather guard to     
cover the sleeve opening during 
construction.

Unique sleeve drain conden-
sate system

A factory-installed drain line connects 
the evaporator drain pan to a vertical 
pipe connection in the 52V basepan. 
Evaporator condensate is delivered 
from the unit to a catch tray in the wall 
sleeve and exits the sleeve through the 

3

/

4

-in. male NPT fitting.

  This design allows the plumber to 
completely pipe the drain to a conden-
sate riser during the pre-installation 
stage, thus decreasing the likelihood of 
condensate connection problems usu-
ally encountered when trying to con-
nect the HVAC (heating, ventilation, 
and air conditioning) condensate drain 
to the riser after the HVAC unit is in-
stalled in the closet.
  This feature also allows the 52V unit 
to be removed for service without 

disconnecting the condensate piping. 
This configuration does not require any 
additional closet space to make the 
drain connection, as do some competi-
tive products.

Redundant systems

If for any reason the primary conden-
sate riser becomes clogged, water will 
fill the catch tray and then be diverted 
through the sleeve to the exterior of 
the building, in a secondary system, 
rather than be allowed to overflow into 
the closet or living area. Rain water en-
tering the sleeve is automatically divert-
ed to the building exterior as well.

Return air options

Ductable return air tabs are provided 
on the inlet of the evaporator coil to 
permit the connection of return air 
ductwork if required by local codes.  
Please note that most installations 
would not normally require ducted re-
turn air.

Attractive appearance

The new flush-style architectural louver 
is an attractive extruded aluminum ar-
chitectural louver that attaches to the 
outside face of the wall sleeve. The 
blades of the grille recess into the wall 
sleeve for a neat, flush appearance. 
Louvers install from the inside of the 
wall sleeve. The 52V unit should not 
be installed into the sleeve before in-
stalling the louver.

Features/Benefits (cont)

Table of contents

Page

Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 
Model Number Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Capacity Ratings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4,5
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Field-Installed Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Base Unit Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7,8
Accessory Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11,12
Typical Wiring Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Controls  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14,15
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Application Data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18,19

Summary of Contents for 52VCR09

Page 1: ...d with a weather guard Flush type exterior architectural louvers Features Benefits Carrier s 52V vertical packaged unit offers design flexibility quality reliabilty and multi function controls Solid s...

Page 2: ...ch sleeve includes a factory installed weather guard to cover the sleeve opening during construction Unique sleeve drain conden sate system A factory installed drain line connects the evaporator drain...

Page 3: ...24 000 Heater Type 00 None ooling Only VE Cooling with Electric Heat VQ Heat Pump VW Cooling with Hot Water Heat Heat Options 02 2 kW Electric Heat sizes 09 and 12 only 03 3 kW Electric Heat 04 4 kW...

Page 4: ...db 60 F wb indoor entering air temperature and 47 F db 43 F wb air entering outdoor unit ELECTRIC HEATER RATINGS 52VER ELECTRIC HEATING AND 52VQR HEAT PUMP UNITS UNIT COOLING CAPACITY Btuh EER 52VCR...

Page 5: ...9 14 7 20 6 32 4 2 0 9 13 6 19 1 30 0 52VWR18 3 Row Coil 760 4 4 7 21 1 29 5 46 3 3 2 7 20 2 28 3 44 5 2 1 3 18 8 26 3 41 3 680 4 4 7 19 7 27 6 43 4 3 2 7 18 9 26 5 41 6 2 1 3 17 6 24 7 38 8 52VWR24 2...

Page 6: ...opening during construction Exterior grilles architectural louvers The exterior grilles attach to the outside face of the wall sleeve and pro vide protection for the unit Interior panel The interior...

Page 7: ...OUTLET CONDENSER INLET 20 66 41 1 4 20 20 LOW VOLTAGE ELECTRICAL KNOCKOUT SERVICE PULLOUT RETURN AIR 6 1 8 10 52VCR VER COOLING ONLY AND COOLING WITH ELECTRIC HEAT UNITS 52VQR09 24 HEAT PUMP UNITS NOT...

Page 8: ...N AIR SERVICE PULLOUT ELECTRICAL KNOCKOUT BLOWER MOTOR 12 3 3 4 1 1 2 3 3 4 2 16 12 3 4 FILTER HOT WATER INLET 1 HOT WATER COIL 52VWR12 24 COOLING WITH HOT WATER HEAT UNITS a52 1342 NOTES 1 Hot water...

Page 9: ...D EXTERIOR GRILLE WALL SLEEVE DIMENSIONS in LEGEND WALL THICKNESS PART NO H W D T 5 8 in 52VX SS 1 43 3 4 21 3 8 26 9 52VX RS 1 52VX RH 1 8 12 in 52VX SS 2 43 3 4 21 3 8 30 13 52VX RS 2 52VX RH 2 12 1...

Page 10: ...C 400 390 380 370 360 350 335 320 LOW H 310 300 290 280 270 260 250 240 18 HIGH 740 730 715 700 685 670 650 630 MEDIUM C 670 660 645 630 615 600 585 570 LOW H 560 550 545 530 515 500 485 470 24 HIGH 9...

Page 11: ...10 200 19 22 20 25 05 4 5 3 38 15 350 11 500 22 25 25 25 18 0 87 1 8 6 5 43 0 72 1 10 00 12 12 20 20 03 3 2 25 10 200 7 700 15 17 20 20 04 4 3 13 600 10 200 19 22 20 25 05 4 5 3 38 15 350 11 500 22 2...

Page 12: ...500 22 25 25 25 06 6 4 50 20 500 15 350 28 33 30 35 08 8 6 00 27 300 20 500 37 43 40 45 10 9 6 75 30 700 23 000 42 48 45 50 24 2 8 1 3 9 9 54 0 74 1 8 03 3 2 25 10 200 7 700 17 19 20 20 04 4 3 00 13...

Page 13: ...C AND MUST BE REMOVED WHEN INSTALLING THE FRONT DESK SWITCH CAP GRN LOCKOUT COOLING GND COM RV LO TEMP LOCKOUT NO BRN RV DEFROST OUTDOOR COM INDOOR BRN GRN RED WHT BLK FD RC R G Y W R G Y W2 C C LEAD...

Page 14: ...ll energize NOTE All three functions are disabled if the 3 minute time delay is active The unit will operate until the thermostat is satisfied Any time that power is applied to the unit and the ther m...

Page 15: ...off Fan operation will be as specified above Reversing valve will remain active Reversing valve heat pump only Type B valves will energize in Heating mode Reversing valve will turn on 15 seconds prior...

Page 16: ...16 RETURN AIR 6 in MIN TO CONDENSATE DRAIN 52V UNIT 1 4 in MIN 1 2 BUBBLE SEALANT WALL SLEEVE EXTERIOR GRILLE a52 1347 Typical installation...

Page 17: ...nditioning systems be properly sized and installed for each application in order to achieve the desired temperature and humidity levels within the space to be conditioned It is strongly recommended th...

Page 18: ...r motor optional filter grille E Heating Coil 1 Electric heating coil shall be 2 to 10 kW electric 2 Hot water heating coil shall have 3 8 in OD high efficiency rifled copper tubes mechanically bonded...

Page 19: ...and hurricane wall sleeve shall be available for coastal areas 2 A thermostat with adjustable high and low tem perature limits shall be available 3 Interior panel shall be available for field install...

Page 20: ...ue or change at any time specifications or designs without notice and without incurring obligations Pg 20 Catalog No 04 52520003 01 Printed in U S A Form 52V 3PD Replaces 52V 2PD Carrier Corporation S...

Reviews: