INTRODUCTION
REFRIGERATION/ELECTRICAL SPECIFICATIONS
CMCT (404A)
CABINET
START
RUN
MODEL
MFG.
MODEL
HP
VOLTS
AMPS AMPS
CMCT-4
Copeland
KAGB-005E-IAA-222
1/2
115
45
8.0
CMCT-6
Copeland
KAGB-005E-IAA-222
1/2
115
45
8.0
CMCT-8
Copeland
KAJB-007E-IAA-222
3/4
115
59
12.0
CMCT-10
Copeland
KALB-010E-CAV-221
1
230/208
33.5
8.1
REFRIGERATION CYCLE
(80° Ambient)
CABINET
REFRIG.
DEFROST
CAP.
CONTROL
CAVITY
MODEL
CYCLE
CYCLE
REFRIG.
OZ.
TUBE
SUCT. DISCH.
SETTING
TEMP.
CMCT-4
8.0 - 115V
6.8 - 115V
404A
22
8' x .042 ID
2#
225#
No. 7
-22°F
CMCT-6
8.0 - 115V
8.4 - 115V
404A
23
8' x .042 ID
5#
223#
No. 7
-19°F
CMCT-8
12.0 - 115V
12.0 - 115V
404A
27
7' x .049 ID
2#
228#
No. 7
-22°F
8.1 - 230V
6.7 - 230V
CMCT-10
404A
29
7' x .054 ID
2#
223#
No. 7
-27°F
4.8 - 115V
4.8 - 115V
NOTE: Refer to Data plate for refrigerant type and charge.
Condenser Fan
............G.E. 5KSM51GG37845 or
Temperature Control
........RANCO A10-4491-00
5KPM51BL-40466 (Reversible Motor)
230 - V.E.M.S. ESP-L35-EM2
Back Pressure Valve
............Sporlan 10# setting
CRO-4-0-20
Time Clock
..............115 Paragon 145-00B (24 Hr.)
CRO-6-0-60 (CMCT-10)
230V Paragon 145-20B (24 Hr.)
Summary of Contents for 52-2038-01
Page 3: ...SECTION I Introduction...
Page 13: ...12 INTRODUCTION WIRING DIAGRAM 00 1667 00 CMCT 4 6 8...
Page 14: ...INTRODUCTION 13 WIRING DIAGRAM 00 1670 00 CMCT 10...
Page 15: ...14 INTRODUCTION WIRING DIAGRAM 00 1934 00 ECMCT 4 6 8 Export Models...
Page 16: ...INTRODUCTION 15 LAMP WIRING DETAIL Upper Raceway Typical...
Page 17: ...SECTION II Maintenance Repair...
Page 23: ...CONDENSING UNIT LAYOUT 24 MAINTENANCE REPAIR...
Page 32: ...UPPER CROSS SECTION CMCT Models...
Page 38: ...SECTION III Parts List...