background image

3

 

LOCK-OUT

TAG

ON

OFF

MAIN

M1

P3

C2

O F F

ON

WR

O F F

ON

C

HI

M

RE

PLA

C

E

S

C

R

EW

L

O

M1

P3

C2

O F F

ON

WR

O F F

ON

C

HI

M

RE

PLA

C

E

S

C

R

EW

L

O

STEP 1

*3-phase units only.
†Single-phase units only.

Fig. 2 — To Light Unit

STEP 5

STEP 4

STEP 3

STEP 2

STEP 8

STEP 10

STEP 9

48HJD005,006*
48HJE004-006*
48HJF004-006*
48HJD007-014
48HJE007-014
48HJF007-014

48HJD005,006†
48HJE004-006†
48HJF004-006†
48HJG005,006
48HJH004-006
48HJK004-006
48HJL005,006
48HJM004-006
48HJN004-006

STEP 7

STEP 6

48HJD005,006*
48HJE004-006*
48HJF004-006*
48HJD007-014
48HJE007-014
48HJF007-014

48HJD005,006†
48HJE004-006†
48HJF004-006†
48HJG005,006
48HJH004-006
48HJK004-006
48HJL005,006
48HJM004-006
48HJN004-006

2-STAGE GAS VALVE

SINGLE-STAGE GAS 

VALVE

2-STAGE GAS VALVE

SINGLE-STAGE GAS 

VALVE

Summary of Contents for 48HJ004

Page 1: ...ll for service Step 11 Set the temperature selector on room thermostat to desired setting WARNING If the information in this manual is not followed exactly a fire or explosion may result causing prope...

Page 2: ...pect the unit and to replace any part of the control system and gas control that has been under water MAINTAINING YOUR UNIT All maintenance should be handled by skilled experienced personnel Your Carr...

Page 3: ...005 006 48HJE004 006 48HJF004 006 48HJD007 014 48HJE007 014 48HJF007 014 48HJD005 006 48HJE004 006 48HJF004 006 48HJG005 006 48HJH004 006 48HJK004 006 48HJL005 006 48HJM004 006 48HJN004 006 STEP 7 STE...

Page 4: ...C HI M R E P L A C E S C R EW L O 3 phase units only Single phase units only STEP 5 48HJD005 006 48HJE004 006 48HJF004 006 48HJD007 014 48HJE007 014 48HJF007 014 48HJD005 006 48HJE004 006 48HJF004 00...

Page 5: ...gent Do not use throwaway filters in place of cleanable filters Table 1 Indoor Air Filter Data for 48HJ NOTE Replacement filters should be UL Underwriters Laborato ries certified or equivalent 1 TURN...

Page 6: ...your qualified local dealer for service Combustion Area and Vent System The com bustion area and vent system should be visually inspected be fore each heating season The normal accumulation of dirt so...

Page 7: ...Inspection of all supply and return air ducts for leaks obstructions and insulation integrity Any problems found should be resolved at the time of inspection 8 Inspection of the unit base for cracks g...

Page 8: ...llel with the pipe indicating that the valve is open Or is the lever at the right angle indicating that the valve is closed If closed has the gas been shut off for safety reasons Otherwise you may ope...

Reviews: