Guide for the owner

When installation and tests are completed explain the Operation
and Maintenance Manual to the owner, with particular attention
to the main operating modes of the air conditioner, such as:

• Turning the unit on and off.

• Functions of the remote controller.

• Removal and cleaning of the air filters.

Leave the two installation manuals for the indoor and outdoor
units with the owner for future use during maintenance
operations or for any other needs.

Configuration (of the unit)

• Press the 

 and 

 buttons of the infrared remote controller

and hold them pressed for more than 5 seconds.

• The display will be cleared, the time segments will display the

configuration item.

• Press 

 button repeatedly until “UCFG” is displayed.

• Press either 

 or 

 button to change the default value of

Heat pump in model type (HP) to new value cooling only
Export
(

1

AC) or cooling only Korea (

2

AC)

• Press 

 button repeatedly until “GFDn” is displayed.

(GFDn = Application select)

• Press either the 

 or 

 button to change the default value of

Application number (1) to the new valve (1

÷

240).

• LOOK OUT! Whichever configuration value changed must

be transmitted to the indoor unit 

 button each time.

• Press 

 button to leave the configuration menu.

Fault code

Once a failure occurs with the indoor unit in operation.
the green LED flashes at intervals of 0.5 seconds.
The fault code is deduced from the number of times the green
LED flahes, blocking unit operation.
Between one flash cycle and the next one, a pause of seconds
3 elapses.

Operating test,

 

fault code and guide for the owner

Table VI: Remote configuration

Confirguration item

      Value

     Description

"CH"

A : Channel A

Remote ID selection

b : Channel B

Defaults to A

"tU"

C : Degrees C

Temperature units

F : Degrees F

Defaults to C

"rc"

HP : Normal Operation

Puts the Remote into

CO 1 : Cooling Only for Export

Cooling Only Mode

CO 2 : Cooling Only for Korea

Defaults to HP

"CL"

12 : 12 Hour Standard

Time Format

(AM/PM)

Defaults to 12

24 : 24 Hour Military

Table V: Unit configuration

Shown on display

Explanation

Description

"rAdr"

It is not used

It is not used

"UCFG"

"HP" : Heat Pump

Unit Configuration

"

1

AC": AC Only for export

Defaults to Heat Pump

"

2

AC": AC Only for korean

"GFdn"

1-

2

40 in increments of 1

GFD Number

Defaults to 1,

1-238 : Mono(1x1

)

   239 : T-kit

   240 : Multi

"ArEA"

It is not used

It is not used

Table IV: Fault code

Green LED

Code

Description

1

System selection Fault

2

Room Air Sensor Fault

3

Indoor coil sensor Fault

5

Compressor Drive Fault

6

Reversing valve Fault

9

Power line feedback fault

Continuous

Indoor thermistor wiring reversed

Summary of Contents for 42PHQ Series

Page 1: ...42PHQ P INSTALLATION MANUAL L L O Y D S R E G I S TER QUALIT Y A S S U R A N C E IS O 900 1...

Page 2: ...ions and weight 2 Nominal data 2 Operating limits 2 Minimum clearances 3 Material supplied 3 General information 4 Warnings avoid 5 Installation 6 7 Refrigerant connections 8 Check 9 Electrical connec...

Page 3: ...nal data Unit is not suitable for operation in laundry premises For sizing of power supply wires and delay type fuses refer to the outdoor unit installation instructions Mod 007 009 012 014 018 024 A...

Page 4: ...ld supplied items are required to complete the installation Name Specification 007 009 Connection pipe 3 8 9 52 mm Gas 1 4 6 35 mm Liquid 012 014 018 024 1 2 12 70 mm Gas 1 4 6 35 mm Liquid Wall sleev...

Page 5: ...onsisting of two units manufactured by Carrier Consult the factory or a qualified system engineer prior to connecting this unit to any other manufacturer s outdoor unit Coupling units which have diffe...

Page 6: ...ondensate dripping Flattening or kinking the refrigerant pipes or condensate pipes Excessive height difference between outdoor and indoor units see installation manual of outdoor unit Unnecessary turn...

Page 7: ...he bracket and the wall Check that the wall hanging bracket does not move This can cause noise during operation If the unit is removed from the wall hanging bracket after installing it onto the wall r...

Page 8: ...e the unit using a tool such as a screwdriver set between the middle area of the body and bottom right of the wall hanging bracket Connecting the pipe can be done more easily if the unit is inclined F...

Page 9: ...to ISO1337 degreased and deoxidized suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa Under no circumstances must sanitary type copper pipe be used Fla...

Page 10: ...screws After installation if there is a significant gap between the unit and wall it can be adjusted by securing the body to the wall hanging bracket using 2 screws Screw holes can be only seen after...

Page 11: ...009 012 014 to the indoor unit sizes 018 024 to the outdoor unit Make electrical connections between units prior to proceeding to mains supply unit connection Before proceeding with the connection to...

Page 12: ...l Cooling only 42PHQ007P 009P 012P 014P 2 Minimum connection wire size Minimum connection wire size between for power supply mm2 indoor and outdoor unit mm2 Models GND L N N Y O W2 42PHQ007P 009P 1 5...

Page 13: ...2P 014P 2 3 Minimum connection wire size Minimum connection wire size between for power supply mm2 indoor and outdoor unit mm2 Models GND L N N Y O W2 42PHQ007P 009P 1 5 1 5 1 5 1 5 1 5 42PHQ012P 014P...

Page 14: ...default value of temperatures in Degrees Celsius C to the new value Degrees Fahrenheit o F Press button repeatedly until rc is displayed Press either the or button to change the default value of Heat...

Page 15: ...ress button to leave the configuration menu Fault code Once a failure occurs with the indoor unit in operation the green LED flashes at intervals of 0 5 seconds The fault code is deduced from the numb...

Page 16: ...Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice December 2003 Printed in Korea 42KU5A54040...

Reviews: