GB - 11
42HQM
E N G L I S H
Operating conditions
• Temperature ranges suitable for unit operation are as follows.
• If the unit operates beyond the max. temperature conditions for a
long time, system diagnostics may detect a malfunction and the
unit will not operate properly.
• If the unit operates under abnormal conditions for a long time with
extremely high humidity, condensed water may drip from the unit.
Minimum operation time
• In normal operation, there is a minimum operation time of 3
minutes between the compressor turning on and turning back off.
Heating features
• At unit start up in heating mode, there will be a preheating period
of about 5 minutes before the unit is ready to deliver warm air.
• During this period the preheating-defrost LED is ON, indicating
preheating.
• When the outdoor temperature is too low, the heating capacity will
be reduced; in this case add another heater appliance to provide
sufficient heating capacity.
Defrost operation
• At outdoor temperatures below 7
°
C, frost may form on the outdoor
unit coil which makes periodic defrosting necessary.
• The defrost time will last from 5 to 10 minutes; during this period
the preheating-defrost LED is ON, indicating the defrosting status.
Power supply failure
If a power supply failure happens during operation, the unit stops
completely.
• When the power supply is restored, the indoor unit operating LED
starts flashing at 1 second intervals.
• To restart the unit, press start button
on the remote control.
• Mobile telephones or other small appliances operating near the air
conditioner may disrupt its operation. In this case turn the unit
main power switch OFF and ON.
• To restart the unit, press start button
on the remote control.
Operating priority
It is not possible to operate the indoor units in various rooms in a
different mode. If the operating mode of a unit in one room is
different from the one located in another room, the unit activated
first is given priority.
Normal operation
Any of the following can occur during normal operation:
• Sometimes a gurgling sound can be heard during operation or
when the unit stops.
- This is the sound of the refrigerant flowing through the unit.
• Bad odours are emitted from the unit.
- Odours such as smoke or cosmetics can accumulate as the
room air circulates through the unit.
- Cleaning the filters will reduce this problem.
- The unit is in defrost mode.
• A crackling sound can sometimes be heard during operation or
when the unit is turned ON.
- This is the sound of plastic expanding due to on abrupt
temperature change.
Troubleshooting
Trouble / Check points /
ACTION
/
The unit does not operate:
• Has the circuit breaker tripped or has the fuse blown?
RESET
THE
CIRCUIT
BREAKER
OR
REPLACE
THE
FUSE
WITH
THE
SPECIFIED
REPLACEMENT
FUSE
.
• Has there been a power failure?
RESTART
OPERATION
WHEN
POWER
IS
RESUMED
.
• Do the LEDs blink quickly?
CALL
YOUR
SERVICE
REPRESENTATIVE
.
Cooling is abnormally low:
• Is the filter blocked with dust?
CLEAN
THE
AIR
FILTER
.
• Has the temperature been set property?
CHECK
AND
RESET
IT
IF
NECESSARY
.
• Are the windows or doors open?
CLOSE
THE
WINDOWS
AND
DOORS
.
• Is anything obstructing the outdoor unit?
REMOVE
THE
OBSTRUCTION
.
• Is the fan speed too low?
CHANGE
THE
FAN
SPEED
SELECTION
.
• Is the unit in Economy or dehumidification operating mode?
CHANGE
TO
COOLING
OPERATION
OR
RESET
.
Heating is abnomally low:
• Is the filter blocked with dust?
CLEAN
THE
AIR
FILTER
.
• Has the temperature been set too low?
CHECK
AND
RESET
IT
IF
NECESSARY
.
• Are the windows or doors open?
CLOSE
THE
WINDOWS
AND
DOORS
.
• Is the unit in Economy operating mode?
CHANGE
TO
HEATING
OPERATION
.
• Is anything obstructing the outdoor unit?
REMOVE
THE
OBSTRUCTION
.
Unit stops during operation:
• Is the OFF timer operating?
RESTART
THE
OPERATION
MODE
.
• Does the LED flash?
CALL
YOUR
SERVICE
REPRESENTATIVE
.
It is impossible to change the selections:
• Are you unable to change the fan speed?
CHECK
IF
THE
DISPLAY
SHOWS
DEHUMIDIFICATION
MODE
.
DRY
(
DEHUMIDIFICATION
).
WHEN
THE
DEHUMIDIFICATION
MODE
IS
SELECTED
,
THE
FAN
SPEED
IS
AUTOMATICALLY
REGULATED
BY
THE
AIR
CONDITIONER
.
IT
CAN
ONLY
BE
SELECTED
IN
COOLING
OPERATING
MODE
.
Is it not possible to select the desired function?
•
MAKE
SURE
THAT
UNIT
ON
SYMBOL
ON
REMOTE
CONTROL
DISPLAY
IS
ILLUMINATED
.
The acoustical “signal received” sound is not emitted:
• Does the indoor unit not emit an acoustical “signal received”
sound either, when start button
is pressed?
WHEN
YOU
PRESS
THE
START
BUTTON
VERIFY
THAT
THE
REMOTE
CONTROL
IS
DIRECTED
TOWARDS
THE
UNIT
SIGNAL
RECEIVER
.
DIRECT
THE
REMOTE
CONTROL
TOWARDS
THE
UNIT
SIGNAL
RECEIVER
,
THEN
PRESS
START
BUTTON
.
ATTENTION:
If the above actions do not correct the operation, consult the
dealer from whom you bought the unit.
Operating features and care - Troubleshooting
MODE
INDOOR
OUTDOOR
COOL
21~32
°
C
15~43
°
C
HEAT
Max. 27
°
C
-5~24
°
C
DRY
Min. 17
°
C
15~43
°
C