background image

 

1

General information 

Read this instruction manual thoroughly before using the unit and 
keep it for further consultation even after installation. 

 

Unit installation 

 The installation must be carried out by a qualified installer. 

 For safety reasons, installers are required to read the general information carefully. 

 Follow all the instructions below to ensure safety. 

 Inspect the unit for damage due to improper transport. Do not install or use damaged 

equipment. 

 To prevent fire, explosion or injury, do not operate the unit near dangerous substances or 

close to naked light equipment. 

 Ensure that national safety code requirements have been followed for the main supply 

circuit. Follow all current national safety code requirements. Ensure that a properly sized 
and connected ground wire is in place. 

 Check that voltage and frequency of the mains power supply are those required for the 

unit to be installed; the available power must be adequate to operate any other appliances 
connected to the same line. 

 Make sure that properly sized disconnecting and safety switches are installed. 

 The manufacturer declines any liability for damage resulting from modifications or errors 

in the electrical or hydraulic connections.    Failure to observe the installation instructions, 
or use of the unit under conditions other than those indicated in the unit installation manual, 
will immediately invalidate the unit warranty. 

 After installation thoroughly test system operation and explain all system functions to the 

owner. 

 All of the packaging materials used for your new appliance are compatible with the 

environment and can be recycled. 

 Dispose of the packaging material in accordance with local requirements. 

 

Unit operation 

 In order to avoid electric shock, fire or injury, stop the unit and disconnect the safety 

switch in case of abnormal events (such as smell of burning) and call Carrier Service for 
further instructions.   

 Do not place containers filled with liquids or other objects onto the unit. 

 

Maintenance 

WARNING: Disconnect the mains power supply prior to any maintenance operations 
or prior to handling any internal parts of the unit. 

 A routine maintenance should be carried out on the unit to check the correct operation of 

the electric connections and protection devices. 

 Maintenance operations must be carried out by specially trained personnel. 

 Do not attempt to repair, move, modify or re-install the unit on your own. To avoid electric 

shock or fire make sure these operations are carried out by qualified personnel only. 

 Contact the qualified service if one of the following events takes place: 

- Hot or damaged power supply cable; 

Summary of Contents for 42CN

Page 1: ...15...

Page 2: ...ation 1 2 Warnings avoid 2 3 Installation 2 4 Water connections 3 5 Electrical connections 4 6 Jumper 4 7 Room Controller 7 8 Operation 7 9 Maintenance 8 10 Service Clause 9 11 Carrier Product Mainten...

Page 3: ...ns Failure to observe the installation instructions or use of the unit under conditions other than those indicated in the unit installation manual will immediately invalidate the unit warranty After i...

Page 4: ...r hazard e g laundry premises Exposure to oil vapours e g kitchens workshops Where curtains or furniture may obstruct free air circulation Waste electrical products should not be disposed of with hous...

Page 5: ...he water flows into the internal condensate drain pan by pouring some water into it If problems are detected check the drain pipe slope and look for possible obstructions Water connections If the unit...

Page 6: ...rding to the wiring diagram Connect hydraulic valve control line to 1 2 for two pipes or to 1 4 for four pipes Before power supply ensure that unit installation OK water valve connection right fan no...

Page 7: ...IP1 1 Unit type OFF 2 pipes ON 4 pipes DIP1 2 Heater OFF Without heater ON With heater DIP1 3 Motor power OFF 45W ON 75W DIP1 4 Control sensor selection OFF Temp sensor on PCB ON Temp sensor on contro...

Page 8: ...P RPM DIP2 6 DIP2 5 DIP2 4 DIP2 3 DIP2 2 DIP2 1 42CN002 12Pa 790 ON OFF OFF OFF OFF ON 30Pa 930 ON OFF OFF OFF ON OFF 50Pa 1070 ON OFF OFF OFF ON ON 42CN003 12Pa 820 ON OFF OFF ON OFF OFF 30Pa 980 ON...

Page 9: ...0 60Hz User should comply with below demand Triple valve contact rating 1A 250VAC interlock point contact rating 3A 250VAC Error codes see table 5 Error Code Reset type Motor start error E1 Auto Motor...

Page 10: ...8 Fig 8 Fig 9...

Page 11: ...Air Filter Take off the filter under the front panel Clean or replace it every 6 months shorten the period of necessary Clean the filters with vacuum cleaner or soap solution Rinse and allow them to...

Page 12: ..._________________________________ ____________________________________________________ Maintainer Signatory _________________ Second Maintenance Record Maintenance Date Failure Description ___________...

Page 13: ...________________________________________________ ____________________________________________________ Maintenance Description ____________________________________________________ _____________________...

Page 14: ...Code _________________________________________________ Contract Number _________________________________________________ Product Type _________________________________________________ Serial Number __...

Page 15: ...y to make the products better fit the clients We reserve the right to change the data without notice Product Manufacturer Shanghai Yileng Carrier Air Conditioning Equipment Co Ltd 868 Yangtai Road Bao...

Reviews: