background image

42 HWX / HQX

GB - 6

Unit warning lights and controls

TEST

EMER

NORMAL

R

N

S

P

Q

TEST

EMER

NORMAL

R

N

S

P Q

Mod.
06 - 08 - 10 - 12

Mod.
18 - 24

N

 Green indicator:

unit ON - unit OFF when not lit.

P

 Yellow indicator:

timer on, when lit.

Q

 Red indicator:

When lit, one of the equipment protections is in operation.

R Operation switch:

Three position switch for “normal”, “emergency” or “test” operation.

“Normal”: switch position for unit standard operation.

“Emergency”: put switch in this position if you want to start the unit
and the infrared remote control does not work (e.g. - exhausted
batteries) or is lost.
With the switch in this position unit will keep the room temperature at
23

°

C at the following conditions:

• Fan speed: medium.

• Timer mode: disabled.

During emergency operation the unit cannot receive signals from
remote controller. After the controller operation has been restored,
reset the switch to the “Normal” position.

“Test” position: this position should only be used by the installer or
by service personnel. During “test” the unit will run in the cooling mode
for 30 minutes. This can be switched off by pushing any button of the
remote controller.

S Signal receiver from remote controller.

Notes:

• When indicator N 

 flashes, there is a unit malfunction.

• When indicator P 

 flashes, the power supply has been turned

off; this indicator is lit only when the timer mode has been
activated.

• When indicator Q 

  is lit, some unit protection has been tripped.

• Table I shows protection devices included in the unit. An activated

protection device is not a sign of unit or system malfunctioning.
After a certain time (differs for each protection) the air conditioner
will automatically return to normal operation.

For correct maintenance of the air conditioner, contact an
authorized service centre.

Table II: Periodical checks

Indoor unit

Clean air filter

Clean drain pipe

Change controller batteries

Outdoor unit

Clean outdoor coil from outside

Clean outdoor coil from inside

Blow air over electric parts

Check electric connections tightening

Clean fan wheel

Check fan tightening

Clean drain pan

Summary of Contents for 42 HQX

Page 1: ...42 HWX 42 HQX 42HWX 42HQX 06 08 10 12 42HWX 18 24 OWNER S MANUAL ...

Page 2: ...ntained in the present manual Remote controls instructions are contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System description 3 Infrared remote controller 4 Display of selected functions 5 Unit protection devices 5 Unit warning lights and controls 6 Periodical che...

Page 3: ...y if installed and tested by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains rotating equipment fan Ensure that this is out of reach for children Be conscious of the room temperature and general comfort particularly when this units is used near children senior or handicapped peo...

Page 4: ...4 5 6 7 9 8 A B 1 2 3 4 5 6 7 9 8 A B 1 Automatic swinging louver 2 Air return 3 Air filters 4 Air outlet 5 Indicators of unit operating status 6 Receiver of signals from remote controller 7 Characteristics nameplate 8 Interconnecting tubing 9 Condensate drain Mod 06 08 10 12 Mod 18 24 ...

Page 5: ...smission symbol 1 will appear on the display see next page When symbol 1 is lit it is not possible to send other signals Anew signal can be sent only after symbol 1 has disappeared Fix to the wall the remote control holder using the screw The remote controller operates with two 1 5 V non re chargeable batteries type IEC LR03 A fading display and reduced controller operating range indicate that the...

Page 6: ...rost cycle Indoor fan off or operating at Heating in During unit operation speed lower than selected heat pump mode Against freeze up Compressor off Cooling During unit operation of cooling coil Against frequent Compressor off Cooling or At unit start compressor cycling heat pump On electric heaters Fan will stop for 30 sec Electric heating At unit stop after unit is turned off 1 In some temporary...

Page 7: ...ould only be used by the installer or by service personnel During test the unit will run in the cooling mode for 30 minutes This can be switched off by pushing any button of the remote controller S Signal receiver from remote controller Notes When indicator N flashes there is a unit malfunction When indicator P flashes the power supply has been turned off this indicator is lit only when the timer ...

Page 8: ...isplay Cooling with dehumidification Heating where available Automatic mode The air conditioner will automatically switch from heating where available to cooling and vice versa in order to maintain the selected temperature Dehumidification only The air conditioner extracts moisture from the air without sensibly changing the room temperature Ventilation fan only Use of the remote controller Setting...

Page 9: ...ton G press the buttons H and I Buttons H and I also serve to adjust the time of day on the display under the word CLOCK Selecting the fan speed button J The fan speed can be selected by pressing button J Symbol on display Low speed for night operation Medium speed High speed at starting to reach temperature Automatic Fan speed will automatically switch to the value required for optimum comfort Wh...

Page 10: ...cloth Do not pour any liquids on the unit Do not use flammable liquids solvents or abrasive powders Optimum comfort and lowest consumption Keep room temperature to comfort levels Do not open doors and windows more frequently than necessary When in cooling avoid direct sun in the room if possible shut curtains or shades Do not obstruct the air intake or outlet of the unit Obstructions will cause a ...

Page 11: ...ller and the unit repeat the operation after having removed the obstacles Receiver on unit or the remote controller are under intense sun radiation avoid direct sun on the unit shut curtains or shades Signal transmission is obstructed by severe interference by electromagnetic field avoid sending signals when computers or household appliances food processors coffee grinders etc are operating close ...

Page 12: ...Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14270 74M9 July 1999 Supersedes Order No 14270 74 July 1997 Printed in Italy ...