GB - 8

42 HWX /  HQX

 Set combined program

The combined program (a selection of a sequence of start and stop
times) will start and stop the air conditioner daily at the programmed time
without any action from the user. To program this function proceed
as follows:

1. Press button G 

 until the symbol of the start time program

shows on the display;  set now your desired start time in the way
indicated in the “set start time” section.

2. Press button G 

 

again to show the symbol for the stop time

program and set your desired stop time.

3. Press button G 

 repeatedly, until the symbol for the combined

program  appears; together with this symbol, the symbols for the
start and stop programs appear alternatively along with the
respective programmed times.

4. To confirm the program, press button C 

. Indicator P 

 on the

unit will light up.

If the programmed times for start and stop coincide, the combined
operation mode will not work.
It is possible to cancel the TIMER operation mode at any time by
pressing button C 

: indicator P 

 on the unit will turn off, and the

indication of the timer mode will disappear from display on the controller.
The unit will store the mode in which was operating at that time: on
if it was in operation, on if it was turned off.
When the timer mode is on (unit indicator P 

 lit) the controller will

always display the symbol relevant to the current timer program; the
time shown is the current time of day.

When only one of the two programs has been selected, i.e. the start
time or the stop time, unit will remain in the selected operating
mode (on or off) after having turned on or off at the selected time.
To change the operating mode, it is necessary to manually start or
stop the unit or select a new program by pressing button C 

.

In case of a power failure during timer mode operation, the unit will
restart, when the power is restored and return to the last operating
position before the power cut: unit indicator P 

 will flash to show

that the Timer mode is off. To reactivate the timer mode, press
button C 

 twice.

Time
adjustment
(buttons H and I)

To set the time for the timer programs selected with button G 

,

press the buttons H 

 and I 

. Buttons H 

 and I 

 also serve

to adjust the time of day on the display under the word CLOCK.

Selecting
the fan speed
(button J)

The fan speed can be selected by pressing button J 

 .

 Symbol on display

Low speed
(for night operation)

Medium speed

High speed
(at starting, to reach temperature)

Automatic
(Fan speed will automatically switch to the value required
for optimum comfort).
When this function is activated, the dotted symbols will flash.

Night stop
(button K)

This function optimizes comfort at night with regard to human
metabolism variations.
One hour after activation of this function, the temperature set in
cooling will increase by 1

°

C, or decrease by 1

°

C if in heating, up to

2

°

C in two hours. After 5 hours the unit will stop completely.

The system will operate at the low fan speed to minimize sound
level. When activating this function, the controller will show the time
when the air conditioner will completely stop for a few seconds.
Press button C 

 to deactivate the function.

Selecting direction
of air flow louver
(button L)

The air flow direction can be adjusted to optimize air distribution in
the room. Press button L   repeatedly to choose one of the
following positions:

Symbol on display

    

Automatic
Air direction will be set automatically.

Symbol on display

6 positions can be chosen.
The louver can be set to one of 6 different air
flow directions.
The choice “Automatic” is recommended for
cooling or  dehumidification modes to avoid
condensation on the louver resulting in dripping
water.

Swing
Louver will continuously swing downward and upward to
obtain an optimal even air distribution in the room.

Adjusting clock time
(button M)

To adjust clock time, put the controller in the ON position by
pressing button B 

 after having positioned the batteries.

The following procedure will allow adjustment of the clock time:

• Gently press the recessed button at the right corner of the

controller battery compartment with a pointed tool (e.g. a pencil
point): the hour figures will flash.
Use buttons H 

 and I 

 to adjust their value to the correct time

of day.

• Press the recessed button a second time and the minute figures

will flash. Adjust them to the correct value in the same way .

• Pressing the recessed button a third time will activate the clock

function.

Use of the remote controller

Summary of Contents for 42 HQX

Page 1: ...42 HWX 42 HQX 42HWX 42HQX 06 08 10 12 42HWX 18 24 OWNER S MANUAL ...

Page 2: ...ntained in the present manual Remote controls instructions are contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System description 3 Infrared remote controller 4 Display of selected functions 5 Unit protection devices 5 Unit warning lights and controls 6 Periodical che...

Page 3: ...y if installed and tested by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains rotating equipment fan Ensure that this is out of reach for children Be conscious of the room temperature and general comfort particularly when this units is used near children senior or handicapped peo...

Page 4: ...4 5 6 7 9 8 A B 1 2 3 4 5 6 7 9 8 A B 1 Automatic swinging louver 2 Air return 3 Air filters 4 Air outlet 5 Indicators of unit operating status 6 Receiver of signals from remote controller 7 Characteristics nameplate 8 Interconnecting tubing 9 Condensate drain Mod 06 08 10 12 Mod 18 24 ...

Page 5: ...smission symbol 1 will appear on the display see next page When symbol 1 is lit it is not possible to send other signals Anew signal can be sent only after symbol 1 has disappeared Fix to the wall the remote control holder using the screw The remote controller operates with two 1 5 V non re chargeable batteries type IEC LR03 A fading display and reduced controller operating range indicate that the...

Page 6: ...rost cycle Indoor fan off or operating at Heating in During unit operation speed lower than selected heat pump mode Against freeze up Compressor off Cooling During unit operation of cooling coil Against frequent Compressor off Cooling or At unit start compressor cycling heat pump On electric heaters Fan will stop for 30 sec Electric heating At unit stop after unit is turned off 1 In some temporary...

Page 7: ...ould only be used by the installer or by service personnel During test the unit will run in the cooling mode for 30 minutes This can be switched off by pushing any button of the remote controller S Signal receiver from remote controller Notes When indicator N flashes there is a unit malfunction When indicator P flashes the power supply has been turned off this indicator is lit only when the timer ...

Page 8: ...isplay Cooling with dehumidification Heating where available Automatic mode The air conditioner will automatically switch from heating where available to cooling and vice versa in order to maintain the selected temperature Dehumidification only The air conditioner extracts moisture from the air without sensibly changing the room temperature Ventilation fan only Use of the remote controller Setting...

Page 9: ...ton G press the buttons H and I Buttons H and I also serve to adjust the time of day on the display under the word CLOCK Selecting the fan speed button J The fan speed can be selected by pressing button J Symbol on display Low speed for night operation Medium speed High speed at starting to reach temperature Automatic Fan speed will automatically switch to the value required for optimum comfort Wh...

Page 10: ...cloth Do not pour any liquids on the unit Do not use flammable liquids solvents or abrasive powders Optimum comfort and lowest consumption Keep room temperature to comfort levels Do not open doors and windows more frequently than necessary When in cooling avoid direct sun in the room if possible shut curtains or shades Do not obstruct the air intake or outlet of the unit Obstructions will cause a ...

Page 11: ...ller and the unit repeat the operation after having removed the obstacles Receiver on unit or the remote controller are under intense sun radiation avoid direct sun on the unit shut curtains or shades Signal transmission is obstructed by severe interference by electromagnetic field avoid sending signals when computers or household appliances food processors coffee grinders etc are operating close ...

Page 12: ...Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14270 74M9 July 1999 Supersedes Order No 14270 74 July 1997 Printed in Italy ...

Reviews: