GENERAL

The 40VMF 4-way ceiling cassette effectively makes each area

served an independently controlled temperature zone. Through

thermostatic control of operations, conditions can be varied to

suit diverse requirements and activities.

The equipment is initially protected under the manufacturer’s

standard warranty; however, the warranty is provided under the

condition  that  the  steps  outlined  in  this  manual  for  initial

inspection,  proper  installation,  regular  periodic  maintenance,

and everyday operation of the unit be followed in detail. This

manual  should  be  fully  reviewed  in  advance  before  initial

installation, start-up, and any maintenance. Contact your local

sales representative or the factory with any questions BEFORE

proceeding.

Table 1 lists physical data for  each unit size. See Fig.  1 for

model number nomenclature. Figure shows unit dimensions.

Table shows components that may or may not be used for a

particular installation.

Fig. 1 —Model Number Nomenclature

CAUTION

DO NOT re-use compressor oil or any oil that has been

exposed to the atmosphere. Dispose of oil per local codes

and regulations. DO NOT leave refrigerant system open to

air any longer than the actual time required to service the

equipment.  Seal  circuits  being  serviced  and  charge  with

dry  nitrogen  to  prevent  oil  contamination  when  timely

repairs  cannot  be  completed.  Failure  to  follow  these

procedures  may  result  in  damage  to  equipment.  For

information about replacement oil type and viscosity, see

the Installation, Start-Up, and Service Instructions for the

38VMAH and 38VMAR outdoor units.

40

VM

F

009

--

3

Equipment Type

40

— Indoor Unit

Product Type

VM

 — VRF

Blank

Voltage (V-Ph-Hz)

3

  — 20 8/2 3 0-1-60

Model Type

F

 — 4-Way Cassette

Capacity (Btuh)

009 

 —   9,000

012

 — 12,000

015

 — 15,000

024

 — 24,000

018

 — 19,100

030

 — 30,000

036

 — 36,000

A40-1914

048

 — 48,000

      

LEGEND
VRF

— Variable Refrigerant Flow

A

Design Revision

Summary of Contents for 40VMF

Page 1: ...in severe personal injury or death WARNING signifies hazards that could result in personal injury or death CAUTION is used to identify unsafe practices which would result in minor personal injury or p...

Page 2: ...2 shows unit dimensions Table 2 shows components that may or may not be used for a particular installation Fig 1 Model Number Nomenclature CAUTION DO NOT re use compressor oil or any oil that has bee...

Page 3: ...Low 32 1 33 0 37 0 40 2 40 2 42 1 47 3 50 5 Medium 34 0 37 3 41 5 43 1 42 5 45 1 50 4 54 0 High 36 7 41 4 45 6 52 5 44 7 49 5 53 9 55 4 UNIT Unit Dimensions W x H x D in 33 1 8 x 9 x 33 1 8 33 1 8 x 1...

Page 4: ...ulation 1 For covering the condensate drain Clamp 1 For connecting the drain Tie rope 5 For insulation Condensate connection 1 For connecting drain PQE connection wire 2 To connect outdoor unit indoor...

Page 5: ...A 048A Dimensions NOTE All dimensions shown in inches 40VMF UNIT SIZE DIMENSION A 009A 9 012A 015A 018A 11 3 4 024A 030A 036A 048A 37 3 8 30 3 4 37 3 8 26 3 4 33 1 8 4 1 8 2 3 4 33 1 8 5 3 4 1 3 4 34...

Page 6: ...ation in a typical room at jobsite Check all critical dimensions such as pipe wire and duct connections requirements Refer to job drawings and product dimension drawings as required Instruct all trade...

Page 7: ...rod For unit weight see Table 3 Fig 7 Mounting Hole Locations Table 3 Unit Weight Includes grille weight MOUNTING UNIT The unit can now be lifted on to the hanging rods for mounting 1 Use rods and fas...

Page 8: ...ing Panel 5 When the panel is secure insert the grille at a 45 angle and latch it in place Step 4 Connect Piping CONDENSATE PIPING The unit is supplied with a 1 1 4 inch OD drain connection to connect...

Page 9: ...ould be carried out as described in the outdoor unit installation manual Step 5 Complete Electrical Connections Installation of wiring must conform to local building codes In absence of local codes wi...

Page 10: ...ACB Auxiliary Control Board AUXH Output For Auxiliary Heat CS Condensate Switch CTON Output for Cooling Operation EEV Electronic Expansion Valve FAN Output for Fan Operation FM Indoor Fan Motor GM Lou...

Page 11: ...Fig 17 below Fig 17 Stripping the Wire 3 Use a suitable screwdriver to fix the communication wire on the outdoor unit communication terminal as shown in Fig 18 below Fig 18 Connecting Communication Wi...

Page 12: ...r unit 2 HA HB Indoor unit 3 HA HB Indoor unit 4 HA HB Indoor unit 5 HA HB Indoor unit 6 HA HB HA HB Touch screen NOTE 24 v DC Power wired controller Field Supplied wired controller HA HB NOTE Power f...

Page 13: ...oor unit 6 HA HB P Q Network Resistor HA HB Touch screen NOTE 24 v DC Power wired controller Field Supplied wired controller HA HB NOTE Power from IDU MAXIMUM WIRING LENGTH L1 L3 3937 ft 18 AWG 2 Core...

Page 14: ...th maintenance schedule In addition Clean condensate tray with suitable cleaning agent Clean the grille and panel EVERY 12 MONTHS Follow 6 month maintenance schedule In addition Be sure all electrical...

Page 15: ...26 Press OK to confirm and exit the setting interface Fig 26 Non Programmable Controller Setting IDU Address Programmable Controller When setting an address connect only one wired controller to an in...

Page 16: ...u want to set See Fig 28 Press MENU OK to send this address to the IDU Fig 28 Programmable Controller Setting IDU Address 4 Press BACK twice or wait 30 seconds to automatically exit the parameter sett...

Page 17: ...ing Mode Conflict Error E1 Communication Error Between Indoor and Outdoor Unit E2 Check Indoor Temperature Sensor T1 E4 Check Evaporator Outlet Temperature Sensor T2B E5 Check Evaporator Temperature S...

Page 18: ...t and Controller Signal wires are short circuited or disconnected Check or reconnect signal wires Signal wires close to electromagnetic source Distance signal wires from electromagnetic source PC boar...

Page 19: ...ETTINGS Fig B SW8 SETTINGS OFF Auto Addressing Mode Default ON Factory Test Mode OFF Normal Mode Default ON Factory Self Checking Mode OFF Standard Indoor Unit Default ON Mode Priority Indoor Unit HP...

Page 20: ...20...

Page 21: ...ht to discontinue or change at any time specifications or designs without notice and without incurring obligations Catalog No 20 40VMF002 01 Printed in U S A Form 40VMF 4SI Pg 21 07 20 Replaces 40VMF...

Reviews: