40 GKX
GB - 3
E N G L I S H
Technical data
Table V: Operating limits
Cooling / Heating
Refer to outdoor unit installation manual.
Nominal single-phase voltage
230V ~ 50Hz
60Hz Special Export Market
Main power supply
Operating voltage limits
min. 198V – max. 264V
min. 187V – max. 253V
Nominal three-phase voltage
400V 3N~ 50Hz
Operating voltage limits
min. 342V – max. 462V
• For power supply wire size and delay type fuses, refer to the outdoor unit installation instructions.
Note: 230V ~ 50Hz.
Table I: Nominal data
POWER INPUT
Cooling only
Cooling (W)
Heating (W)
40GKX012---703
75
–
40GKX018---703
80
–
40GKX024---703
105
–
40GKX028---703
108
–
40GKX036---703
140
–
40GKX048---703
185
–
40GKX060---703
230
–
40GKX112W--703
75
1575
40GKX118W--703
80
2580
40GKX124W--703
105
2605
40GKX128W--703
108
3108
40GKX136W--703
140
3140
40GKX148W--703
185
3185
40GKX160W--703
230
3230
POWER INPUT
Heat pump
Cooling (W)
Heating (W)
40GKX012---703
75
75
40GKX018---703
80
80
40GKX024---703
105
105
40GKX028---703
108
108
40GKX036---703
140
140
40GKX048---703
185
185
40GKX060---703
230
230
40GKX112W--703
75
1575
40GKX118W--703
80
1580
40GKX124W--703
105
1605
40GKX128W--703
108
2108
40GKX136W--703
140
2140
40GKX148W--703
185
2185
40GKX160W--703
230
2230
Model
R
C
Y
O
(1)
W2
(1)
S1
(1)
S2
(1)
from 12 to 60
1.0
1.0
1.0
1.0
1.0
0.75 0.75
• The power supply cable to the electric heaters must be H07 RN-F type.
• The connection cables between indoor and outdoor units must be:
- type A05 RN-F (3 x 1) (R - C -Y)
for cooling only units (A/C)
- type A05 RN-F (2 x 1) (R - C)
for heat pump units (H/P)
- type A05 RN-F (3 x 1) (Y - O - W2) for heat pump units (H/P)
- type A05 RN-F (2 x 0,75) (S1 - S2) for heat pump units (H/P)
Table II: Connection wire size between indoor and outdoor units (mm
2
)
(1)
Heat pump unit only
Table III: Technical data of electric heaters (if installed)
Heat pump
Cooling only
Model
12
18
24
28
36
48
60
12
18
24
28
36
48
60
Electric heater
kW
1.5
1.5
1.5
2 x 1.0 2 x 1.0 2 x 1.0 2 x 1.0
1.5
1.5
1.5
2 x 1.0 2 x 1.0 2 x 1.0 2 x 1.0
+
+
+
+
+
+
capacity
1.0
1.0
2 x 0.5 2 x 0.5 2 x 0.5 2 x 0.5
Supply
V
230
230
230
230
230
230
230
230
230
230
400
400
400
400
voltage (ph)
(1 ph)
(1 ph)
(1 ph)
(1 ph)
(1 ph)
(1 ph)
(1 ph)
(1 ph)
(*)
(*)
(*)
(*)
(*)
(*)
Max. current draw
A
6.5
6.5
6.5
8.7
8.7
8.7
8.7
6.5
10.8
10.8
7.5
7.5
7.5
7.5
Control device
INTERNEC electronic control
Safety thermostat
N
°
1Automatic reset thermostat
N
°
1 Manual reset thermostat (electric)
Power supply cables
mm
2
3 x 1.5 3 x 1.5 3 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 3 x 1.5 3 x 2.5 3 x 2.5 5 x 1.5 5 x 1.5 5 x 1.5 5 x 1.5
Recommended fuse (gL type)
A
8
8
8
10
10
10
10
8
12
12
10
10
10
10
*In areas with a 2 kW limit for single-phase electric heaters it is possible to divide the power supply on two phases and neutral of a three phase supply with neutral.
Use cable type HO7 RN-F - 4 x 1.5 mm
2
- 400V 2N~
Description
Quantity
Use
Installation instructions
1
Indoor unit installation
Owner's Manual
1
Correct use
Fresh air intake baffle
1
Air renewal
Table IV:
Material supplied