2
1
/
2
"
1
9
/
16
"
AIR DISCHARGE
4
3
/
16
"
3
/
8
IN.
DIA.
LIQUID LINE
CONN
1
3
/
4
"
2
15
/
16
"
FIELD POWER SUPPLY CONN
7
/
8
IN.
DIA HOLE WITH
1
1
/
8
IN. DIA KNOCKOUT
AND
1
3
/
8
IN. DIA KNOCKOUT
10
1
/
2
"
F
G
A
FIELD CONTROL SUPPLY
CONN
7
/
8
IN.
DIA HOLE
AIR DISCHARGE
AIR DISCHARGE
AIR IN
AIR IN
AIR IN
H
DIA VAPOR LINE CONN
3
/
8
IN. DIA TIEDOWN
KNOCKOUTS (2)
PLACES IN BASEPAN
B
1
1
/
4
"
M
ACCESS
PANEL
L
K
C
D
E
J
C L
1.
Allow 30 in.
clearance to service side of unit, 48 in. above unit, 6 in.
on one side, 12 in. on remaining side, and 24 in. between units for proper airflow.
Minimum outdoor operating ambient in cooling mode is 55
°
F (unless low ambient control is used) max 125
°
F.
2.
Maximum outdoor operating ambient in heating mode is 66
°
F.
3.
Series designation is the 13th position of the unit model number.
4.
Center of gravity .
5.
NOTES:
A96517
Dimensions
(In.)
UNIT
SIZE
SERIES
UNIT
DIMENSIONS
MINIMUM
MOUNTING
PAD
DIMENSIONS
A
B
C
D
E
F
G
H
J
K
L
M
Support
Feet
Snow
Stand
024
30
39-13/16
30
34-15/16
4
9-3/4
27-1/2
33-7/8
5/8
8-3/16
15-7/8
14-3/8
14-1/4
26
X
3
2
3
1
X
3
5
030
30
33-13/16
30
34-15/16
4
9-3/4
21-1/2
27-7/8
3/4
8-3/16
14
13-1/8
13-3/4
26
X
3
2
3
1
X
3
5
036
30
27-13/16
30
34-15/16
4
9-3/4
15-1/2
21-7/8
3/4
8-3/16
16-1/8
14-1/8
13-1/4
26
X
3
2
3
1
X
3
5
042
30
27-13/16
30
34-15/16
4
9-3/4
15-1/2
21-7/8
7/8
8-3/16
16-1/4
14
13-1/8
26
X
3
2
3
1
X
3
5
048
30
39-13/16
30
34-15/16
4
9-3/4
27-1/2
33-7/8
7/8
8-3/16
16-1/4
14-1/4
14-1/2
26
X
3
2
3
1
X
3
5
060
31
39-13/16
30
34-15/16
4
9-3/4
27-1/2
33-7/8
7/8
8-3/16
16
13-3/4
13-3/4
26
X
3
2
3
1
X
3
5
5