Carrier 38YXA Preliminary Product Fact Sheet Download Page 3

Accessories

ORDERING NO.

DESCRIPTION

KAATD0101TDR

Time-Delay Relay—All Sizes

KSALA0301410

Low-Ambient Pressure Switch—All Sizes

KAAFT0101AAA

Evaporator Freeze Thermostat—All Sizes

KHAIR0101AAA

Isolation Relay—All Sizes

KSAHS1501AAA

Start Assist—Capacitor and Relay—Sizes 024–042

KSAHS1601AAA

Start Assist—Capacitor and Relay—Size 048, 060

KAACS0201PTC

Start Assist—PTC—All Sizes

KAACH1201AAA

Crankcase Heater—Sizes 024–042

Standard

Crankcase Heater—Sizes 048, 060

KHAOT0301FST

Outdoor Thermostat—All Sizes

KHAOT0201SEC

Secondary Outdoor Thermostat—All Sizes

KHASA0101AAA

Service Alarm—All Sizes

KHAIC0101AAA

Interface Control (Optimizer II®)—All Sizes

KSATX0201HSZ

Bi-Flow TXV (Hard Shutoff)—Sizes 024, 030

KSATX0301HSZ

Bi-Flow TXV (Hard Shutoff)—Sizes 036, 042

KSATX0401HSZ

Bi-Flow TXV (Hard Shutoff)—Size 048

KSATX0501HSZ

Bi-Flow TXV (Hard Shutoff)—Size 060

KH45LG140 (RCD)

Bi-Flow Filter Drier (Suction Line)—Sizes 024–036

KH45LG141 (RCD)

Bi-Flow Filter Drier (Suction Line)—Sizes 042–060

KHALS0401LLS

Liquid-Line Solenoid Valve—All Sizes

KSASF0101AAA

Support Feet—4 In. (4)—All Sizes

KHASS0206MPK

Snow Stand—18 In.—All Sizes

THERMOSTAT/SUBBASE PKG

DESCRIPTION

TSTATCCNHP01-A

Thermostat—Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

TSTATCCPHP01-A

Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

TSTATCCPDF01-A

Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, Dual Fuel
Must be used with Outdoor Air Temperature Sensor (TSTATXXSEN01)

TSTATCCPRH01-A

Thermidistat™ Control—Programmable Thermostat with Humidity Control

--HH--07AT-215

Thermostat—Manual Changeover, Non-Programmable, °F, 2-Stage Heat, 1-Stage Cool

TSTATXXSEN01

Outdoor Air Temperature Sensor

TSTATXXNBP01

Backplate for Non-Programmable Thermostat

TSTATXXPBP01

Backplate for Programmable Thermostat

TSTATXXCNV10

Thermostat Conversion Kit (4 to 5 Wire)—10 Pack

Accessory Usage Guideline

ACCESSORY

REQUIRED FOR LOW-AMBIENT

APPLICATIONS

(BELOW 55°F)

REQUIRED FOR LONG-LINE

APPLICATIONS*

(OVER 50 FT)

Crankcase Heater

Yes

Yes

Evaporator Freeze Thermostat

Yes

No

Compressor Start Assist—Capacitor and Relay

Yes

Yes

R-410A Low-Ambient Pressure Switch

Yes

No

Wind Baffle

See Low-Ambient

Pressure Switch Instructions

No

Support Feet

Recommended

No

R-410A Hard Shutoff TXV

Yes†

Yes†

R-410A Liquid-Line Solenoid Valve for Heating

No

See Long-Line

Application Guideline

* For tubing line sets between 50 and 175 ft, refer to the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using

R-410A Refrigerant.

† Required for all applications.

3

Summary of Contents for 38YXA

Page 1: ...mpressor discharge gas an energy efficient fan and fan motor to move air more efficiently and the InViroFlow design for an improved airflow pattern which requires less energy All units contain scroll compressors specially designed for use with R 410A FEATURES SEER up to 14 5 and HSPF up to 8 5 with specified Carrier equipment Silencer System Environmentally safe refrigerant R 410A High pressure sw...

Page 2: ... 20 20 Rows 1 1 2 2 2 2 Circuits 2 3 3 3 4 5 VALVE CONNECTION In ID Sweat Vapor 5 8 3 4 3 4 7 8 7 8 7 8 Liquid 3 8 REFRIGERANT TUBES In OD Vapor 0 50 Ft Tube Length 5 8 3 4 3 4 7 8 7 8 1 1 8 Vapor Alternate 3 4 ACR 7 8 7 8 7 8 7 8 7 8 Vapor RST Not Permitted 3 4 1 1 8 1 1 8 3 4 and 1 1 8 3 4 and 1 1 8 3 4 Liquid All Applications 3 8 Tube diameters are for lengths up to 50 ft For tubing lengths gre...

Page 3: ...Changeover Non Programmable F C 2 Stage Heat 1 Stage Cool TSTATCCPHP01 A Thermostat Auto Changeover 7 Day Programmable F C 2 Stage Heat 1 Stage Cool TSTATCCPDF01 A Thermostat Auto Changeover 7 Day Programmable F C Dual Fuel Must be used with Outdoor Air Temperature Sensor TSTATXXSEN01 TSTATCCPRH01 A Thermidistat Control Programmable Thermostat with Humidity Control HH 07AT 215 Thermostat Manual Ch...

Page 4: ...ance ment Standard Rating Carrier Gas Furnace or Accessory TDR Accessory TXV TC COP TC COP 024 30 FX4ANF030 25 000 TDR TXV 13 00 11 50 25 000 3 30 16 600 2 30 8 00 030 30 FX4ANF030 29 000 TDR TXV 13 00 11 40 30 000 3 50 18 500 2 34 8 00 036 30 FX4ANF042 35 000 TDR TXV 13 00 11 30 35 000 3 35 21 600 2 34 7 70 042 30 FV4ANF003 40 500 TDR TXV 13 10 11 30 40 500 3 35 25 400 2 45 7 70 048 30 FV4ANF005 ...

Page 5: ...or operating ambient in heating mode is 66 F 3 Series designation is the 13th position of the unit model number 4 Center of gravity 5 NOTES A96517 Dimensions In UNIT SIZE SERIES UNIT DIMENSIONS MINIMUM MOUNTING PAD DIMENSIONS A B C D E F G H J K L M Support Feet Snow Stand 024 30 39 13 16 30 34 15 16 4 9 3 4 27 1 2 33 7 8 5 8 8 3 16 15 7 8 14 3 8 14 1 4 26 X 32 31 X 35 030 30 33 13 16 30 34 15 16 ...

Page 6: ...rant R 410A as with other HFCs is only compatible with POE oils Vacuum pumps will not remove moisture from oil Do not use liquid line filter driers with rated working pressures less than 600 psig Do not install a suction line filter drier in liquid line POE oils absorb moisture rapidly Do not expose oil to atmosphere POE oils may cause damage to certain plastics and roofing materials Wrap all filt...

Page 7: ...door unit is indoor coil above 30 ft indoor coil below 30 ft See items 8 and 9 following 8 For interconnecting tubing lengths greater than 50 ft consult the Residential Split System Application Guideline and Service Manual for Air Conditioners and Heat Pumps using R 410A Refrigerant 9 If ANY refrigerant tubing is buried provide a minimum 6 in vertical rise to the valve connections at the unit Refr...

Page 8: ...rvice Training plus hands on the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting fewer callbacks Course descriptions and schedules are in our catalog CALL FOR FREE CATALOG 1 800 962 9212 Packaged Service Training Classroom Service Training Copyright 1997 CARRIER Corp 7310 W Morris St Indianapolis IN 46231 38yxa1pf Manufacturer reserves the ri...

Reviews: