Table 3—Airflow Selection for 58UHV,58UXV Furnaces (CFM)

38YDA

UNIT

SIZE

FURNACE

MODEL/HEATING

SIZE

FURNACE AIRFLOW SELECTION BOARD SETTINGS

Cool Size

Jumper

Position

AC/HP

Jumper

Position

Cool CFM Per Ton Jumper Position

400

350

315

Heat Pump Heating Airflow*

High

Low

High

Low

High

Low

036

060

HI

HP—EFFY

1260

780

1100

680

990

585

HP—CMFT

1135

700

990

610

895

555

080

M-LO

HP—EFFY

1260

790

1100

700

990

625

HP—CMFT

1135

715

990

630

895

560

100

LO

HP—EFFY

1260

780

1090

775

990

700

HP—CMFT

1130

700

980

700

890

700

120

LO

HP—EFFY

1195

865

1085

785

985

785

HP—CMFT

1075

780

975

750

885

750

048

080

HI

HP—EFFY

1635

1040

1470

915

1325

820

HP—CMFT

1510

940

1325

825

1190

740

100

M-HI

HP—EFFY

1680

1040

1465

915

1325

820

HP—CMFT

1510

935

1320

825

1190

740

120

M-HI

HP—EFFY

1650

1070

1465

975

1315

930

HP—CMFT

1485

965

1320

880

1185

835

060

100

HI

HP—EFFY

2085

1300

1840

1150

1655

1025

HP—CMFT

1890

1170

1655

1035

1490

920

120

HI

HP—EFFY

2110

1300

1865

1140

1640

1080

HP—CMFT

1900

1170

1650

1025

1475

970

* Heat Pump Cooling Airflow always matches HP—EFFY Heat Pump Heating Airflow.

Table 4—Airflow Selection for 58MVP Furnaces (CFM)

38YDA

UNIT

SIZE

HIGH-SPEED

A/C SETUP

SWITCH POSITION

FURNACE MODEL/HEATING SIZE

LOW-SPEED

CF SETUP

SWITCH POSITION

060

080

100

A/C-1

A/C-2

A/C-3

High

Low

High

Low

High

Low

CF-1

CF-2

CF-3

036

OFF

OFF

ON

1200

800

1200

800

1200

800

OFF

ON

OFF

048

OFF

ON

ON

1600

1000

ON

ON

OFF

060

OFF

ON

ON

1600*

1000

ON

ON

OFF

* Efficiency rating obtained at 1600 CFM. If 2000 CFM is desired, adjust airflow per 58MVP Installation Instructions.

Table 5—Airflow Selection for FK4C or 40FKA Fan Coils (CFM)

38YDA

UNIT

SIZE

FK4C

UNIT

SIZE

EASY SELECT CONTROL BOARD

HEATING CFM*

COOLING CFM*

AC/HP

SIZE

(Blue Wire)

AC/HP

CFM ADJUST

(Black Wire)

SYSTEM TYPE

(Orange Wire)

High

Low

High

Low

036

001

036

NOM

HP—EFF

1100

680

1100

680

HP—COMFORT

990

615

002

036

NOM

HP—EFF

1100

680

1100

680

HP—COMFORT

990

615

003

036

NOM

HP—EFF

1100

680

1100

680

HP—COMFORT

990

615

005

036

NOM

HP—EFF

1100

680

1100

680

HP—COMFORT

990

615

006

036

NOM

HP—EFF

1100

745

1100

745

HP—COMFORT

990

670

048

005

048

NOM

HP—EFF

1470

910

1470

910

HP—COMFORT

1320

820

006

048

NOM

HP—EFF

1470

995

1470

995

HP—COMFORT

1325

895

060

006

060

NOM

HP—EFF

1835

1240

1835

1240

HP—COMFORT

1655

1120

* Airflow CFMs are given with AC/HP CFM ADJUST jumper set at NOM. Airflow can be ad15% or -10% by selecting HI or LO respectively.

14

Summary of Contents for 38YDA

Page 1: ...rom improper installation of equipment 1 Locate unit away from windows patios decks etc where unit operation sound may disturb customer 2 Ensure that vapor and liquid tube diameters are appropriate to...

Page 2: ...door operating ambient in cooling mode is 55 F and the maximum outdoor operating ambient in cooling mode is 125 F The maximum outdoor operating ambient in heating mode is 66 F Step 5 Elevate Unit Accu...

Page 3: ...uct Data Sheet for factory approved indoor units Outdoor unit contains correct system refrigerant charge for opera tion with indoor unit of same size when connected by 15 ft of field supplied or facto...

Page 4: ...for 2 speed units Do not attempt to operate unit below 55 F in cooling mode or modify control system for low ambient operation Compressor dam age may occur Available electrical accessories include lat...

Page 5: ...ate unit in a vacuum or at negative pressure Do not disable low pressure switch In scroll compressor applications Dome temperatures may be hot To prevent personal injury wear safety glasses protective...

Page 6: ...LE THERMOSTAT MODEL 2S TYPICAL FAN COIL TWO SPEED HEAT PUMP See notes 7 8 9 and 11 W2 G W2 O R W3 R L H R1 COOL HEAT STAGE 1 COOL HEAT STAGE 2 24 VAC HOT Y Y2 A D A97498 R C C Y1 W3 O TYPICAL FAN COIL...

Page 7: ...UMPER J2 JUMPER TWO SPEED HEAT PUMP See notes 7 8 9 11 and 23 DH Y1 Y1 W W1 O W2 Y1 W2 O W1 Y Y2 Y2 W2 W3 Y Y2 O W2 COOL HEAT STAGE 1 COOL HEAT STAGE 2 HEAT STAGE 3 RVS COOLING H A98628 R Y2 R Y2 C C...

Page 8: ...FURNACE TWO SPEED HEAT PUMP See notes 7 9 11 14 and 24 W R Y1 R O W2 G L W3 Y H R1 FAN HEAT STAGE 3 RVS COOLING 24 VAC HOT K A98587 24 VAC HOT 24 VAC COMM HEAT STAGE 3 R C G W W1 Y Y2 R C RVS COOLING...

Page 9: ...C Y2 W3 W2 R Y1 O C DHUM HUM B S1 S2 R C HEAT STAGE 3 COOL HEAT STAGE 2 RVS COOLING FAN 24 VAC HOT 24 VAC COMM N A HUMIDIFY See notes 7 11 14 15 16 17 18 and 25 N A OUTDOOR SENSOR CONNECTION Y Y2 HUM...

Page 10: ...W2 Y1 W2 24 VAC COMM N A OUTDOOR SENSOR CONNECTION C B S1 S2 CARRIER PROGRAMMABLE THERMOSTAT MODEL 2S G H R1 FAN HEAT STAGE 3 COOL HEAT STAGE 2 RVS COOLING 24 VAC HOT P A97497 24 VAC HOT 24 VAC COM HE...

Page 11: ...CE WITH ICM BLOWER MOTOR TWO SPEED HEAT PUMP See notes 6 7 9 11 12 14 21 and 24 R Y1 R O G L W3 W W1 Y Y2 W2 Y1 COOL HEAT STAGE 2 FAN HEAT STAGE 3 RVS COOLING 24 VAC HOT W A97496 R C C W2 TWO STAGE VA...

Page 12: ...3 W2 O C DHUM HUM B S1 S2 R W2 O Y1 R COM HUM PL9 10 DEHUM HEAT STAGE 3 HEAT COOL STAGE 1 HEAT COOL STAGE 2 RVS COOLING FAN 24 VAC HOT 24 VAC COM DEHUMIDIFY HUMIDIFY N A OUTDOOR SENSOR CONNECTIONS Y Y...

Page 13: ...t pump MUST have a high pressure switch for dual fuel applications 15 Outdoor air temperature sensor must be attached in all dual fuel applications 16 Thermidistat Dip Switch 1 should be set in the ON...

Page 14: ...w Selection for 58MVP Furnaces CFM 38YDA UNIT SIZE HIGH SPEED A C SETUP SWITCH POSITION FURNACE MODEL HEATING SIZE LOW SPEED CF SETUP SWITCH POSITION 060 080 100 A C 1 A C 2 A C 3 High Low High Low Hi...

Page 15: ...ersects measured liquid service valve pressure 6 To obtain required subcooling temperature at a specific liquid line pressure add refrigerant if liquid line temperature is higher than indicated or rec...

Page 16: ...door coil heat and minimize the steam cloud effect SECOND STAGE LATCHING Mechanical thermostats operate with a staging differential of 2 F droop Carrier electronic thermostats are droopless meaning th...

Page 17: ...ature The cycle terminates when coil thermistor reaches 80 F 5 or defrost period reaches a maximum of 10 minutes FURNACE INTERFACE This feature provides a heat pump lockout upon a demand for auxiliary...

Page 18: ...appears at control board If a PTC trip occurs 3 times the control locks out outdoor unit operation and provides a malfunction signal at control PRESSURE SWITCH PROTECTION The outdoor unit is equipped...

Page 19: ...s the resistance decreases A thermistor is used to sense outdoor ambient Refer to Fig 14 for resistance values versus temperature If outdoor ambient thermistor should fail a malfunction signal appears...

Page 20: ...e Training plus hands on the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting fewer callbacks Course descriptions and schedules are in our catalo...

Reviews: