5
Accessories
N/A — Not applicable in this application.
* Isolation relay required.
† Use with low-ambient controller.
‡ See Compressor data table.
** Hard shut-off TXV requires compressor start assist on recip compressors. See Compressor Data table.
ORDERING NUMBER
DESCRIPTION
KAAWS0101AAA
Winter Start Control
KAATD0101TDR
Time-Delay Relay
KAAFT0101AAA
Evaporator Freeze Thermostat†
KHAIR0101AAA
Isolation Relay†
Standard
Cycle Protector—Units with scroll compressor‡
KSACY0101AAA
Cycle Protector—Units with recip compressor‡
KAAHS0601AAA
Compressor Start Assist (Capacitor/Relay) Sizes 018 (331, 341), 024 (351, 361), 030 (361, 371)
KAAHS0701AAA
Compressor Start Assist (Capacitor/Relay) Size 036 (371) 1 Phase
N/A
Compressor Start Assist (Capacitor/Relay)—3 Phase and Scroll Units‡
KAACS0201PTC
Start Assist (PTC)—Sizes 036–060 1 Phase Scroll Units‡
Standard
Start Assist (PTC)—Sizes 018–036 1 Phase Recip Units‡
N/A
Start Assist (PTC)—3 Phase
Standard
Crankcase Heater—Sizes 018 (331, 341), 024 (351, 361), 030 (361, 371), 036 (371), All 3 Phase
KAACH1201AAA
Crankcase Heater—Sizes 036 (361), 042–060 1 Phase
KSASH1101COP
Sound Blanket—Sizes 018 (331), 024 (351), 030 (371, 571)
Standard
Sound Blanket—Size 030 (361), 036 (371, 571, 671)
KSASH1301TEC
Sound Blanket—Sizes 018 (341), 024 (361)
KSASH1901CYL
Sound Blanket—Size 036 (361, 561, 661)
KSASH2001CYL
Sound Blanket—Sizes 042–060 (321, 521, 621)
KSASH1201COP
Sound Blanket—Size 036 (511, 531)
KSASH0801TEC
Sound Blanket—Size 036 (521)
KSASH1701COP
Sound Blanket—Sizes 042–060 (331, 531, 631)
KHAOT0301FST
Outdoor Thermostat
KHAOT0201SEC
Secondary Outdoor Thermostat
KHAIC0101AAA
Interface Control (Optimizer II)
KHAIC0201AAA
Interface Control (Outdoor Thermostat and Lockout Relay)
KHATX0901HSO**
TXV (Hard Shut-off)—Size 018
KHATX1001HSO**
TXV (Hard Shut-off)—Size 024
KHATX1101HSO**
TXV (Hard Shut-off)—Size 030
KHATX1201HSO**
TXV (Hard Shut-off)—Sizes 036, 042
KHATX1301HSO
TXV (Hard Shut-off)—Size 048
KHATX1401HSO
TXV (Hard Shut-off)—Size 060
KHATX0201RPB
TXV (RPB)—Size 018
KHATX0301RPB
TXV (RPB)—Size 024
KHATX0401RPB
TXV (RPB)—Size 030
KHATX0501RPB
TXV (RPB)—Sizes 036, 042
KHATX0601RPB
TXV (RPB)—Size 048
KHATX0701RPB
TXV (RPB)—Size 060
Standard
Low-Pressure Switch
KSAHI0201HPS
High-Pressure Switch
KHALS0101LLS
Liquid Solenoid Valve (LSV)
Not Available
Support Feet
Not Available
Snow Rack
P251-0083
Low-Ambient Controller* (RCD)
P504-8083S
Filter Drier—Bi-flow Sizes 018-036
P504-8163S
Filter Drier—Bi-flow Sizes 042-060
THERMOSTAT/SUBBASE
PKG
DESCRIPTION
--HH--07AT-175
Thermostat, 2-Stage Heat, 1-Stage Cool, Auto/Manual Changeover—
°
F
--HH--93AZ-195
Subbase for Manual Changeover Thermostat
--HH--93AZ-196
Subbase for Auto Changeover Thermostat
--HH--07AE--001
Thermostat (1 Piece) Night Setback, 2-Stage Heat, 1-Stage Cool—
°
F/
°
C Option,
5-2 Day Programmable