background image

14

13

To complete the installation, perform the following checks before the trial operation.

     Strength of the installation site for both indoor and outdoor sides, confirm no obstruction of the unit air outlet or return.

     Tightness of Refrigerant piping connection and confirm no leakage

     Electric wiring connections are correctly completed and unit has been grounding connected

 

    Check the total length of the piping and record the volume of the additional charged refrigerant

      

The power supply should comply with the rated voltage of the air conditioner

      

Insulation of the pipe

      

Drainage

      

6.1 FINAL CHECK LIST

Set the air conditioning under the COOLING mode with the remote controller (or manual button) and check the running status of both 

indoor unit and outdoor unit. In case of any malfunction, resolve it according to chapter “Trouble shooting” in the “Service Manual”.

Indoor unit

      

Whether the buttons (such as ON/OFF, MODE, TEMPERATURE, FAN SPEED etc.) on the remote controller work well.

      

Whether the louver moves normally.

      

Whether the room temperature is adjusted well.

      

Whether the indicator lights on the display panel are normal.

      

Whether the “manual” button works well.

      

Whether the drainage is normal.

      

Whether there is a vibration or abnormal noise during the operation.

      

Whether the indoor unit works well in COOLING or HEATING mode.

Outdoor unit

      

Whether there is a vibration or abnormal noise during the operation.

      

Whether the air flow, noise or condensate water generated by the air conditioner have disturb your neighborhood.

      

Whether there is any refrigerant leakage.

6.3 TRAIL OPERATION

When restart the unit, there will be approximately 3 minutes delay for the compressor to run for protection.

CAUTION

6.2 MANUAL OPERATION

Manual operation can be accessed by pressing manual button

Press the manual button repeatedly to change modes as follows:

     Once = AUTO mode [heat, cool or fan, 24

°C and auto fan speed.

     Twice = COOLING mode [switch to AUTO mode after 30 minutes (mainly used for trial operation)]

     Three times = OFF 

6. FINAL CHECK AND TRAIL OPERATION

Manual Button

AUTO/COOL

Summary of Contents for 38QHM009

Page 1: ...WALL MOUNTED AIR CONDITIONER INSTALLATION MANUAL...

Page 2: ...installation service or disposal When any leakage of the contained fluorinated gas is detected the leak shall be stopped and repaired as soon as possible 4 Only qualified service personnel are allowed...

Page 3: ...efrigerant gas leaks during installation ventilate the area immediately Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater stove or cooking device Expos...

Page 4: ...e Step 1 Determine Wall Hole Position Step 2 Attach Mounting Plate Step 3 Drill Wall Hole Fix the mounting plate horizontally and level on the wall with five or more A type screws Install The Mounting...

Page 5: ...t is hooked securely Use a wedge to prop up the unit if rear tubing is needed Hang The Indoor Unit For proper orientation of the refrigerant piping electrical cable and drain lines refer to below Fig...

Page 6: ...th anchor bolts M10 to prevent it from collapsing Install the foundation and vibration proof rubbers to directly support the bottom surface of the fixing leg that is in contact with the bottom plate o...

Page 7: ...he service port of the gas side packed valve Connect the charge hose to the port of the vacuum pump Fully open the handle Loof manifold gauge Operate the vacuum pump to evacuate air from the system un...

Page 8: ...FAN SPEED etc on the remote controller work well Whether the louver moves normally Whether the room temperature is adjusted well Whether the indicator lights on the display panel are normal Whether t...