1.3 INSTALLATION SITE CHOOSING
Indoor Unit
- A location which can bear the weight of indoor unit.
- Do not install indoor units near a direct source of heat such as direct sunlight or a heating appliance.
- A location which provides appropriate clearances as below figure.
- Moving parts of appliance must be installed/located at the level not less than 2.3m from the floor.
Outdoor Unit
- A location which is convenient to installation and not exposed to strong wind. If unit is exposed to strong winds it is recommended
that a wind baffle be used.
- A location which can bear the weight of outdoor unit and where the outdoor unit can be mounted in a level position.
- A location which provides appropriate clearances as below figure.
Do not install the indoor or outdoor units in a location with special environmental conditions.
Confirm that there is enough room for installation and maintenance.
Note: Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
2.3m or more
60cm or more
30cm or more
12cm or more
12cm or more
30cm or more
200cm or more
60cm or more
Step 1: Determine Wall Hole Position
Step 2: Attach Mounting Plate
Step 3: Drill Wall Hole
Fix the mounting plate horizontally and level on the wall with five or more A-type
screws.
Install The Mounting Plate
Drill a 65mm hole on the wall which is slightly tilted towards the outside.
Drill Hole In The Wall
Indoor
Wall
Outdoor
5-7mm
2.1 INDOOR UNIT MOUNTIN PLATE
2.2 INSTALLATION PROCESS
2. INDOOR UNIT INSTALLATION
1. PREPARING FOR INSTALLATION
15cm or more
The refrigerant lines may be routed
in any of the four directions.
Left
tubing
Right tubing
Right-rear
tubing
Left-rear tubing
If drain cap exist, the drain hose
can be exchanged.
Drain cap
Put a cushioning material to have
installation space for rear tubing.
Cushioning
material
The mounting plate will look like one of the following depending on the unit size.
The holes for fixing anchors should be 5mm. (unit:mm)
42QHM018ES*/42QHM024ES*
Indoor unit outline
1186/46.7
21.5/0.85
257/10.1
275/10.8
343/13.5
45/1.8
Indoor unit outline
990/39
315/12.4
135/5.3
260/10.2
23.2/0.9
45/1.8
42QHM009ES*/42QHM012ES*
Left rear side
refrigerant
pipe hole
φ
65/2.6
Left rear side
refrigerant
pipe hole
φ65/2.6
Right rear side
refrigerant
pipe hole
φ
65/2.6
Right rear side
refrigerant
pipe hole
φ65/2.6
Step 4: Connect Pipe
L
N
S
Step 5: Connect Wire