8-6. Others
8-6-1. Gas leak test
Fig. 8-6-1
•
Check the flare nut connections, valve stem cap
connections and service port cap connections for
gas leak with a leak detector or soap water.
8-6-2. Test operation
To switch the TEST RUN (COOL) mode, press
RESET button for 10 seconds.
(The beeper will make a short beep.)
FILE NO. SVM-10035
A
B
Service port cap connection
Valve stem cap connection
Flare nut connections
(Outdoor unit)
Flare nut connections
(Indoor unit)
Valve stem cap connection
8-6-3. Auto restart setting
This product is designed so that, after a power failure,
it can restart automatically in the same operating mode
as before the power failure.
Information
The product was shipped with Auto Restart function
in the off position. Turn it on as required.
<How to set the auto restart>
1. Press and hold down the RESET button on the
indoor unit for for 3 seconds to set the operation.
( 3 beep sound and OPERATION lamp blink 5
time/sec for 5 seconds)
•
Do not operate ON timer and OFF timer.
2. Press and hold the RESET boutton on the indoor
unit for 3 seconds to concel the operation. ( 3 beep
sound but OPERATION lamp does not blink)
8-6-4. Remote Controller A or B Selection
Setting
When two indoor units are installed in the separated rooms, it
is not necessary to change the selector switches.
<Remote control A or B Selection>
•
When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may receive
the remote control signal simultaneously and operate. In this
case, the operation can be preserved by setting either one
i
ndoor unit or remote control to B setting. (Both are set to A
setting in factory shipment.)
•
The remote control signal is not received when the settings of
indoor unit and remote control are different.
•
There is no relation between A setting/B setting and A room/B
room when connecting the piping and cables.
<
Remote Control A-B Selection
>
To separate using of remote control for each indoor unit in case
of 2 air conditioner are installed nearly.
the remote control signal simultaneously and operate. In this
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold button on the Remote Control by the tip of the
pencil. "00" will be shown on the display.
4. Press during pushing , "B" will show on the display
and"00" will disappear and the air conditioner will turn OFF. The
Remote Control B is memorized.
Note : 1. Repeat above step to reset Remote Control to be A.
2. Remote Control A have not "A" display.
3. Detault setting of Remote Control from factory is A.
Fig. 8-6-3
“B” Display
“00” Display
OFF
ON
RESET button
Fig. 8-6-2
RESET
Hi POWER FILTER PAP TIMER OPERATION
−
37
−
Summary of Contents for 38NY018N