8
−
4-
2
. Outdoor Unit
No.
Parts name
Type
Specifications
Output (Rated) 750W , 2poles, 1 phase, 220
−
240V, 50Hz
1 Compressor PA108X1C-4FZDN Winding resistance (
Ω
) C-R C-S
(at 20°C) 3.75 4.75
Output (Rated) 30W, 6poles, 1 phase, 220
−
240V, 50Hz
2 Fan motor (for outdoor) Winding resistance (
Red-Black White-Black
(at 20°C) 237 380
3
Running capacitor
DS451155NPQB
AC 450V~, 1.5
µ
F
(for fan motor)
4
Running capacitor
RS44B256U0213S AC 440V~, 25
µ
F
(for compressor)
5
Solenoid coil
(for 4-way valve)
−
AC 220
−
240V~
WLF-240-30A
Overload relay
LPAP960B U/T: 6.1A(80°C), Open: 135±5°C, Close: 78±11°C
6
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) AFN-220-20-4D AC Motor with 145 °C thermo fuse
2
Thermo sensor (TA-sensor)
10k at 25 C
3 Micro power module (M01) GPS-9W-AA
4 Microcontroller unit (IC30)
TMP87CM40AFG-6P69
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) *SS11V-R06270 27mH, 600mA
7 Bridge rectifier (DB01) DB105G 1A, 600 V
8 Capacitor (C63) EKMH401VSN470MP20S 47
m
F, 400 V
9 Fuse (F01) BET6.3A 6.3A, 250VAC
10 Varistor (R21, R22) SR561K14DO
560 V
11 Resistor (R319)
RF-2TK5R6 5.6 , 2 W
12 Louver motor 24BYJ48 12VDC
13 Relay (Comp., RY01)
G4A-1A-E-CA Rating 20A/AC250 V, 12VDC
14 Relay (Fan, RY03)
202N-1AC-C E
Rating 3A/AC250 V, 12VDC
15 Relay (Solenoide, RY04) Rating 3A/AC250 V, 12VDC
W
W
W
°
°
202N-1AC-C E
FILE NO. SVM-10036
Ω
)
Summary of Contents for 38NQ009N
Page 63: ......