Refrigerant Leakage Detection Diagnosis and Solution (EC)
Troubleshooting
Error Code
EC
Malfunction decision conditions
Define the evaporator coil temp.T2 of the compressor just starts running as Tcool. In the beginning 5 minutes
after the compressor starts up, if T2 <Tcool-35.6°F(Tcool-2°C) does not keep continuous 4 seconds and this
situation happens 3 times, the display area shows “EC” and AC turns off.
Supposed Causes
• T2 sensor faulty
• Indoor PCB faulty
• System problems, such as leakage or blocking
Is cool air blowing from the indoor air outlet?
Yes
Power
OFF
.
Wait 2 minutes then restart the unit.
ŽĞƐƚŚĞƉƌŽďůĞŵƐƟůůĞdžŝƐƚ͍
Check the system for leaks.
Are any leaks present?
No
No
Check the system for blockages and
ŝĨĂŶLJĞdžŝƐƚ͕ĐůĞĂƌƚŚĞŵ͘
Check the T2
sensor.
Is it securely
ĂƩĂĐŚĞĚ͍
Yes
Replace the indoor PCB.
Repair the leak and recharge the refrigerant.
Yes
Yes