If the compressor stops caused by the room temperature rising, the indoor fan will be forced to run 127
seconds with breeze. During this period, the anti-cold-wind is disabled.
If the machine runs in rating capacity test mode, the indoor fan will run with rating speed and the
anti-cold-wind function is disabled.
Indoor fan speed can be set as high, medium, low or auto fan and the anti-cold-wind function is
preferential.
Auto fan action in heating mode:
2.5
2
High
Low
1
Medium
1.5
3.3.4 Defrosting mode
Condition of defrosting:
----T4
>
0
℃
,
When the units are running, if the following two items are satisfied, the units start defrosting:
The units run with T3
<
3
℃
for 40 minutes and T3 keeps lower than TCDI
℃
for more than 3 minutes.
The units run with T3
<
3
℃
for 80 minutes and T3 keeps lower than TCDI+2
℃
for more than 3 minutes.