Table 2—38HDR Electrical Data

38HDR

UNIT

SIZE

V---PH---Hz

VOLTAGE

RANGE*

COMPRESSOR

OUTDOOR FAN MOTOR

MIN

CKT

AMPS

FUSE/BKR

AMPS

RLA

LRA

FLA

NEC

Hp

kw

Out

Min

Max

018

208/230---1---60

187

253

9.0

48.0

0.80

0.125

0.09

12.1

20

024

208/230---1---60

187

253

12.8

58.3

0.80

0.125

0.09

16.8

25

030

208/230---1---60

187

253

14.1

73.0

1.45

0.25

0.19

19.1

30

036

208/230---1---60

187

253

14.1

77.0

1.45

0.25

0.19

19.1

30

208/230---3---60

187

253

9.0

71.0

1.45

0.25

0.19

12.7

20

460---3---60

414

506

5.6

38.0

0.80

0.25

0.19

7.8

15

048

208/230---1---60

187

253

21.8

117.0

1.45

0.25

0.19

28.7

50

208/230---3---60

187

253

13.7

83.1

1.45

0.25

0.19

18.6

30

460---3---60

414

506

6.2

41.0

0.80

0.25

0.19

8.6

15

060

208/230---1---60

187

253

26.4

134.0

1.45

0.25

0.19

34.5

60

208/230---3---60

187

253

16.0

110.0

1.45

0.25

0.19

21.5

35

460---3---60

414

506

7.8

52.0

0.80

0.25

0.19

10.6

15

LEGEND

:

FLA

--- Full Load Amps

LRA

--- Locked Rotor Amps

NEC

--- National Electrical Code

RLA

--- Rated Load Amps (compressor)

* Permissible limits of the voltage range at which the unit will operate

satisfactorily

NOTES

:

1. Control circuit is 24---V on all units and requires external power

source. Copper wire must be used from service disconnect to unit.

2. All motors/compressors contain internal overload protection.
3. In compliance with NEC (U.S.A. Standard) requirements for multi-

motor and combination load equipment (refer to NEC Articles 430

and 440), the overcurrent protective device for the unit shall be fuse

or breaker.

4. Motor RLA values are established in accordance with UL (Underwrit-

ers’ Laboratories) Standard 465 (U.S.A. Standard).

5. 38HDR018---030 units are only available in single---phase voltage.
6.

Unbalanced 3---Phase Supply Voltage

Never operate a motor where a phase imbalance in supply voltage is

greater than 2%.

Use the following formula to determine the percent-

age of voltage imbalance:

= 100 X

max voltage deviation from average voltage

average

EXAMPLE

: Supply voltage is 460---3---60

AB = 452v

BC = 464v

AC = 455v

Average Voltage = 452 + 464 + 455

3

=

1371

3

=

457

Determine maximum deviation from average voltage:
(AB) 457---452 = 5v
(BC) 464---457 = 7v
(AC) 457---455 = 2v
Maximum deviation is 7v.

Determine percentage of voltage imbalance

% of voltage imbalance = 100 x 7

57

=

1.53%

This amount of phase imbalance is satisfactory as it is below the maximum

allowable of 2%.

IMPORTANT

: Contact your local electric utility company immediately if the

supply voltage phase imbalance is more than 2%.

38H

D

R

Summary of Contents for 38HDR

Page 1: ...brazing operations Have fire extinguisher available Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit Consult local building codes...

Page 2: ...ee Fig 2 Locate unit so that condenser airflow is unrestricted on both sides Refer to Fig 2 Unit may be mounted on a level pad directly on base legs or mounted on raised pads at support points See Fig...

Page 3: ...1 13 16 3 4 1 16 1 2 1 2 0 8 1 2 1 6 7 8 0 3 7 16 0 6 1 2 1097 1131 9 433 4 468 3 774 7 498 5 893 4 1017 9 354 2 215 9 479 4 88 165 4 UNIT SIZE M OPERATING WT in mm lb kg 38HDR 018 5 8 15 88 166 75 8...

Page 4: ...n If any section of pipe is buried there must be a 6 in 152 4 mm vertical rise to the valve connections on the outdoor unit If more than the recommended length is buried refrigerant may migrate to coo...

Page 5: ...lves are closed from the factory and are ready for brazing After wrapping the service valve with a wet cloth the tubing set can be brazed to the service valve using either silver bearing or non silver...

Page 6: ...2 3 3 FPI 20 20 20 20 20 20 HIGH PRESSURE SWITCH Cut In psig Cutout psig 420 25 650 10 LOW PRESSURE SWITCH Low Cutout psig Low Cut in psig 20 5 45 25 REFRIGERANT LINES Connection Type Sweat Liquid Lin...

Page 7: ...unit as measured along the control voltage wires use No 16 AWG color coded wire to avoid excessive voltage drop NOTE All wiring must conform to NEC and local codes NOTE Operating unit on improper lin...

Page 8: ...al power source Copper wire must be used from service disconnect to unit 2 All motors compressors contain internal overload protection 3 In compliance with NEC U S A Standard requirements for multi mo...

Page 9: ...Heater COMP Compressor Motor EQUIP Equipment GND Ground HPS High Pressure Switch LPS Low Pressure Switch OFM Outdoor Fan Motor OL Overload TB Terminal Board Splice Field Terminal Marked Terminal Unma...

Page 10: ...isconnect switch Lock out and tag switch with a suitable warning label Outdoor Fan A reinforced wire mount holds the outdoor fan assembly in position See Fig 7 for proper mounting position 38HDR Unit...

Page 11: ...before brazing The service valve cannot be field repaired therefore only a complete valve or valve stem seal and service port caps are available for replacement Refrigerant Charging WARNING PERSONAL...

Page 12: ...9 58 7 3 13 72 160 56 2 13 44 262 86 9 30 50 364 110 0 43 33 466 128 7 53 72 596 148 4 64 67 60 8 6 13 00 162 57 0 13 89 264 87 4 30 78 366 110 4 43 56 468 129 0 53 89 600 149 0 65 00 62 10 0 12 22 16...

Page 13: ...02 62 34 60 33 58 32 56 31 54 30 52 29 208 64 36 62 34 60 33 58 32 56 31 54 30 215 66 37 64 36 62 34 60 33 58 32 56 31 222 68 38 66 37 64 36 62 34 60 33 58 32 229 70 39 68 38 66 37 64 36 62 34 60 33 2...

Page 14: ...r conditions Inspect coil monthly and clean as required Fins are not continuous through coil sections Dirt and debris may pass through first section become trapped between the row of fins and restrict...

Reviews: