background image

Fig. 11—Typical 24-v Circuit Connections using Carrier Model HP Thermostat with Smart Heat and No Outdoor
Thermostat, 1 Outdoor Thermostat, or Supplemental Heat Relay and Carrier Model 2S Thermostat with FK4C

Fan Coil and Smart Staging

A97543

24 VAC HOT

R

G

W/W1

Y/Y2

O/W2

RVS COOLING

C

B

S1

S2

SUPPLEMENTAL

HEATING

RELAY

CARRIER

PROGRAMMABLE

THERMOSTAT

MODEL HP

FA, FB, FC, FH

FAN COIL WITH

SMART HEAT

 HEAT 
PUMP

Y1/W2

L

R

C

Y

G

O

W2T

W3

W2D

Y

0

R

C

O

W2

Y

INDOOR FAN

HEAT STAGE 2

COOL/HEAT
STAGE 1

NOT USED

24 VAC COM

NOT USED

TROUBLE 

OPTIONAL
OUTDOOR
SENSOR
CONNECTION

CUT
JW1

  

SHR

  

SHR

  

ODT

A97541

24 VAC HOT

R

G

W/W1

Y/Y2

O/W2

RVS COOLING

C

B

S1

S2

CARRIER

PROGRAMMABLE

THERMOSTAT

MODEL HP

FA, FB, FC, FH

FAN COIL WITH

SMART HEAT

HEAT 

PUMP

Y1/W2

L

R

C

Y

G

O

W2T

W3

W2D

Y

0

R

C

O

W2

Y

INDOOR FAN

HEAT STAGE 2

COOL/HEAT
STAGE 1

NOT USED

24 VAC COM

NOT USED

TROUBLE 

OPTIONAL
OUTDOOR
SENSOR
CONNECTION

JW1

A97540

24 VAC HOT

R

G

W/W1

Y/Y2

Y/Y2

Y1/W2

R

DH

RVS COOLING

C

B

L

S1

S2

Y

W2

CARRIER

PROGRAMMABLE

THERMOSTAT

MODEL 2S

FK4C

FAN COIL

 HEAT 
PUMP

G

O

O/W2

W2

Y1

C

W1

R

O

24 VAC COMM

HEAT STAGE 2

HEAT STAGE 3

COOL/HEAT
STAGE 1

FAN

RVS HEATING

TROUBLE

OUTDOOR
SENSOR
CONNECTION

C

J1 JUMPER

REMOVE

J2 JUMPER

FOR HEAT

STAGING

Smart Sequencing Application:  Model 2S thermostat with 
switch C OFF and switch D ON uses single-speed heat pump, 
FK4 fan coil with selected 2:1 size ratio heaters.  Provides 3 
stages of auxiliary heat for even heating comfort via W/W1 
and Y1/W2.  Refer to FK4 Installation Instructions.

A97542

24 VAC HOT

R

G

W/W1

Y/Y2

O/W2

RVS COOLING

C

B

S1

S2

CARRIER

PROGRAMMABLE

THERMOSTAT

MODEL HP

ONE

OUTDOOR

THERMOSTAT

 HEAT 
PUMP

Y1/W2

L

R

C

Y

G

O

W2T

W3

W2D

Y

0

R

C

O

W2

Y

INDOOR FAN

HEAT STAGE 2

COOL/HEAT
STAGE 1

NOT USED

24 VAC COM

NOT USED

TROUBLE 

OPTIONAL
OUTDOOR
SENSOR
CONNECTION

CUT
JW1

  

ODT

FA, FB, FC, FH

FAN COIL WITH

SMART HEAT

7

Summary of Contents for 38BYW

Page 1: ...installation of equipment 1 Locate unit away from windows 2 Ensure that vapor and liquid tube diameters are appropriate to capacity of unit 3 Run refrigerant tubes as directly as possible by avoiding...

Page 2: ...per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate drainage of unit Step 6 Check Defrost Thermostat Check defrost thermostat to ensure it...

Page 3: ...alve To prevent damage to unit or service valves observe the following Use a brazing shield Wrap service valves with wet cloth or use a heat sink material Connect outdoor unit to indoor sections using...

Page 4: ...th CONNECT GROUND AND POWER WIRES Connect ground wire to ground connection in control box for safety Connect power wiring to contactor as shown in Fig 9 CONNECT CONTROL WIRING Route 24 v control wires...

Page 5: ...ling On a call for cooling thermostat makes circuits R O R Y and R G Circuit R O energizes reversing valve switching it to cooling position Circuit R Y energizes contactor starting outdoor fan motor a...

Page 6: ...deline For buried line applications refer to Residential Split System Buried Line Application Guideline Required for Low Ambient Controller full modulation feature and MotorMaster Control only Fig 10...

Page 7: ...NOT USED 24 VAC COM NOT USED TROUBLE OPTIONAL OUTDOOR SENSOR CONNECTION JW1 A97540 24 VAC HOT R G W W1 Y Y2 Y Y2 Y1 W2 R DH RVS COOLING C B L S1 S2 Y W2 CARRIER PROGRAMMABLE THERMOSTAT MODEL 2S FK4C...

Page 8: ...4 VAC COM HEAT STAGE 2 CUT JW1 SHR SHR FA FB FC FH FAN COIL SMART HEAT ODT A97410 24 VAC HOT R C Y G O RVS COOLING W2 OTHER HP THERMOSTAT FA FB FC FH FAN COIL SMART HEAT HEAT PUMP E R C Y G O W2T W3 W...

Page 9: ...NALS MUST BE PRESENT 8 Y1 AND O CONNECTIONS TO 2 STAGE FURNACES MAY NOT EXIST OR MAY ONLY BE A WIRE RATHER THAN A SCREW TERMINAL Fig 13 Typical 24 v Circuit Connections using Carrier Model DF Thermost...

Page 10: ...10...

Page 11: ...oduct theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products...

Page 12: ...46231 38byw1si Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 5a 5a PC 101 Catalog No 563...

Reviews: