Fig. 9—Label Wiring 327417-101

A05022

T1

CONT

LOGIC

C

C

Y

Y

DFT

DFT

C

R

R

W2

O O

DR

DR

*LPS

*DTS

*HPS

RVS

FACTORY POWER WIRING
FIELD POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
CONDUCTOR ON CIRCUIT BOARD
COMPONENT CONNECTION
1/4 - INCH QUICK CONNECT TERMINALS
FIELD SPLICE
JUNCTION
CAPACITOR (DUAL RUN)
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
COMPRESSOR
CONTACTOR
CIRCUIT BOARD
DEFROST THERMOSTAT
DEFROST RELAY AND CIRCUITRY
DISCHARGE TEMP. SWITCH
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
OUTDOOR FAN MOTOR
REVERSING VALVE SOLENOID
START CAPACITOR
START RELAY
START THERMISTOR

CAP
*CH
*CHS
COMP
CONT
CB
DFT
DR
*DTS
*HPS
*LPS
OFM
RVS
*SC
*SR
*ST

*  MAY BE FACTORY OR FIELD INSTALLED.

-LEGEND-

1.   COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT
         THERMAL PROTECTION.
2.   TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE
          (N.E.C.) AND LOCAL CODES.
3.   N.E.C. CLASS 2, 24 V CIRCUIT, MIN. 40 VA REQUIRED.
4.   USE COPPER CONDUCTORS ONLY FROM DISCONNECT TO UNIT.
5.   MUST USE THERMOSTAT AND SUB-BASE AS STATED IN PRE-SALE
         LITERATURE.
6.   IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED
        SECONDARY, CONNECT THE GROUNDED SIDE TO "C" ON THE
         CIRCUIT BOARD.
7.   IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED,
         USE THE SAME OR EQUIVALENT WIRE.
8.   CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX
         FOR TIGHTNESS.
9.   DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES 
         HAVE BEEN OPENED.
10. USE CONDUCTORS SUITABLE FOR AT LEAST 75ºC (167ºF).   

NOTES:

327417-101 REV. B

SCHEMATIC DIAGRAM  (LADDER FORM)

CONNECTION  DIAGRAM

13

23

*CH

CONT

DR

OF1

OF2

L2

21

11

CONT

EQUIP

GND

L1

COMP

OFM

CAP

*CHS

H

C

F

*ST

+t°

S

C

R

CONT

208/230 1Ø

POWER

SUPPLY

EQUIP GND

L1

11 21

13 23

L2

BLK

YEL

YEL

OFM

*CH

CAP

COMP

BLK

BLK

*CHS

BLK

or

RED

BLK

RED or BLK

BLU

H

C

F

BRN

YEL

YEL

S

C

R

*ST

BLU

+t°

ORG

ORG

or

or

RVS

BLK

BLK

DFT

BLK

or

PNK

PNK

or

BLK

G

L

E

R

W2

O

Y

C

TERMINAL BLOCK

INDOOR UNIT

RED

WHT

ORN

YEL

BLK

CB

G

W3

L

E

R

W2

O

Y

C

INDOOR THERMOSTAT (NOTE #5)

DR

OF1

OF2

C Y O W2 R

Y

T1

LOGIC

90

30

S

P

EED

UP

R

C

C

DFT

O

PNK

PNK

HK32EA001

*LPS

*HPS

YEL 

YEL

BLU 

BRN

YEL

BRN

YEL or BLU

YEL

ORG

ORG

BLK

BLK

**

** 

BOARD MAY HAVE 60  

         AS MIDDLE SELECTION

50 

FIELD SELECTED TIME PERIOD
BETWEEN DEFROST CYCLES (MINUTES)

JUMPERED TEST PINS (USE METAL OBJECT), FIELD SPEED-UP CYCLE

HEAT CYCLE:

90 MIN. ACCELERATED TO 21 SEC.
60 MIN. ACCELERATED TO 14 SEC.
50 MIN. ACCELERATED TO 12 SEC.
30 MIN. ACCELERATED TO 7 SEC.
10 MIN. ACCELERATED TO 2 SEC.

DEFROST CYCLE:

90

30

SPEED

UP

 

50

**

**

10

Summary of Contents for 38AYC Series

Page 1: ...101 208 230 1 60 9 10 38YCS 018 048 31 34 327418 101 208 230 1 60 10 11 38YCS 060 31 327417 101 208 230 1 60 9 10 38YKC 018 32 33 327418 101 208 230 1 60 10 11 38YKC 024 042 31 33 327418 101 208 230...

Page 2: ...ARI rating conditions cannot be obtained ARI rating conditions are equivalent to DOE test A conditions See product data literature for required indoor air flow rates and for use of line lengths over...

Page 3: ...C and local codes 3 N E C class 2 24 V circuit min 40 VA required 4 Use copper conductors only from disconect to unit 5 Must use thermostat and sub base as stated in pre sale literature 6 If indoor s...

Page 4: ...ION JUMPERED TEST PINS USE METAL OBJECT FIELD SPEED UP CYCLE 327209 101 REV A CONNECTION DIAGRAM 1 Compressor and fan motor furnished with inherent thermal protection 2 To be wired in accordance with...

Page 5: ...t wire 8 Check all electrical connections inside control box for tightness 9 Do not attempt to operate unit until service valves have been opened 10 Use conductors suitable for at least 75 C 167 F 11...

Page 6: ...ERHEAT F AT LOW SIDE SERVICE PORT 52 54 56 58 60 62 64 66 68 70 72 74 76 55 9 37 60 7 65 6 70 7 75 6 9 12 15 18 21 24 28 31 34 37 80 5 8 12 15 18 21 25 28 31 35 85 8 11 15 19 22 26 90 5 9 13 16 20 24...

Page 7: ...79 77 75 73 38 87 85 83 81 79 77 75 73 71 36 85 83 81 79 77 75 73 71 69 34 83 81 79 77 75 73 71 69 67 32 81 79 77 75 73 71 69 67 65 30 79 77 75 73 71 69 67 65 63 28 77 75 73 71 69 67 65 63 61 26 75 7...

Page 8: ...85 83 81 79 77 75 73 38 87 85 83 81 79 77 75 73 71 36 85 83 81 79 77 75 73 71 69 34 83 81 79 77 75 73 71 69 67 32 81 79 77 75 73 71 69 67 65 30 79 77 75 73 71 69 67 65 63 28 77 75 73 71 69 67 65 63 61...

Page 9: ...field power to unit with correct phasing The Phase Rotation Monitor will not allow the contactor to be energized if thephasing is not correct If phasing is reversed simply interchange any two of the...

Page 10: ...D SIDE TO C ON THE CIRCUIT BOARD 7 IF ANY OF THE ORIGINAL WIRE AS SUPPLIED MUST BE REPLACED USE THE SAME OR EQUIVALENT WIRE 8 CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX FOR TIGHTNESS 9 DO NOT...

Page 11: ...SOLENOID START CAPACITOR START RELAY START THERMISTOR CAP CH CHS COMP CONT CB DFT DR DTS HPS LPS OFM RVS SC SR ST MAYBEFACTORYORFIELDINSTALLED LEGEND 1 COMPRESSOR AND FAN MOTOR FURNISHED WITH INHERENT...

Page 12: ...IN 46231 38a1w Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 3d 2e PC 101 Catalog No 38A...

Reviews: